Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
  • 1,4-dioxane
  • 123-91-1, pyrene and chrysene
  • semivolatiles and rxi5silms
  • 8270
You are currently filtering on:
  • rxi-5sil
Geranium Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Citronella Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Bergamot Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Lemon Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Peppermint Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Grapefruit Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Tea Tree Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Citronella Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Geranium Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Tea Tree Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Peppermint Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Lavender Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Patchouli Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Rosemary Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Bergamot Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Lemon Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Grapefruit Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Lavender Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Rosemary Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Patchouli Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Lemongrass Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
rxi-5sil
Lemongrass Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
rxi-5sil
Bergamot Oil on Rxi-5Sil MS
rxi-5sil
Lemon Oil on Rxi-5Sil MS
rxi-5sil
Rosemary Oil on Rxi-5Sil MS
rxi-5sil
Patchouli Oil on Rxi-5Sil MS
rxi-5sil
Lavender Oil on Rxi-5Sil MS
rxi-5sil
Citronella Oil on Rxi-5Sil MS
rxi-5sil
Eucalyptus Oil on Rxi-5Sil MS
rxi-5sil
Peppermint Oil on Rxi-5Sil MS
rxi-5sil
Grapefruit Oil on Rxi-5Sil MS
rxi-5sil
Tea Tree Oil on Rxi-5Sil MS
rxi-5sil
Geranium Oil on Rxi-5Sil MS
rxi-5sil
Lemongrass Oil on Rxi-5Sil MS
rxi-5sil
TNRCC 1006 Retention Time Marker Mix on Rxi-5Sil MS
rxi-5sil
Diesel Fuel #2 Standard on Rxi-5Sil MS by Split Injection
rxi-5sil
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
rxi-5sil
MA DEP EPH Aromatics on Rxi-5Sil MS
rxi-5sil
MA DEP EPH Aliphatics on Rxi-5Sil MS
rxi-5sil
NJ DEP EPH Aromatics on Rxi-5Sil MS
rxi-5sil
Diesel Fuel 2 Standard on Rxi-5Sil MS
rxi-5sil
NJ DEP EPH Aliphatics on Rxi-5Sil MS
rxi-5sil
MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
rxi-5sil
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
rxi-5sil
NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
rxi-5sil
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
rxi-5sil
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
rxi-5sil
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
rxi-5sil
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
rxi-5sil
EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rxi-5Sil MS (SIM)
rxi-5sil
EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rxi-5Sil MS (SIM)
rxi-5sil
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at 10x the Method Reporting Limit (SIM Analysis)
rxi-5sil
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at Method Reporting Limit (SIM Analysis)
rxi-5sil
EPA Method 525.3 Internal and Surrogate Standards on Rxi-5Sil MS
rxi-5sil
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi-5Sil MS
rxi-5sil
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
rxi-5sil
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
rxi-5sil
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
rxi-5sil
EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
rxi-5sil
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
rxi-5sil
Nonylphenol, Bisphenol A, 4-tert-Octylphenol, Nonylphenol Monoethoxylate, and Nonylphenol Diethoxylate on the Rxi-5Sil MS by ASTM D7065-11 (Constant Flow)
rxi-5sil
Cannabis Potency Compounds on Rxi-5Sil MS
rxi-5sil
Combination Run of U.S. EPA Methods 521 and 522, Nitrosamines and 1,4-Dioxane, on Rxi-5Sil-MS by CSR-LVSI
rxi-5sil
50 µL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column
rxi-5sil
10 μL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column
rxi-5sil
0.50 ng/L N-Nitrosodimethylamine (NDMA) Laboratory Fortified Drinking Water Sample Extract on Rxi-5Sil MS
rxi-5sil
MOSH/MOAH Compounds on Rxi-5Sil MS and Hydroguard-Treated MXT With Allure Silica (Online LC/GC Coupling)
rxi-5sil
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
rxi-5sil
GCxGC-TOFMS Analysis of Unfortified Tobacco Extract After QuEChERS Extraction and dSPE Cleanup With 25 mg PSA and 7.5 mg GCB
rxi-5sil
GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200
rxi-5sil
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
rxi-5sil
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
rxi-5sil
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
rxi-5sil
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
rxi-5sil
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
rxi-5sil
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
rxi-5sil
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Lemon Using Rxi-5Sil MS and Rtx-200
rxi-5sil
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
rxi-5sil
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
rxi-5sil
Zoom of Pesticide Standard by GCxGC-TOFMS Using Rxi-5Sil MS and Rtx-200
rxi-5sil
Semivolatile GC-MS Tune Verification Mix on Rxi-5Sil MS
rxi-5sil
Select Carbamate, Organophosphorus, Aniline, Conazole, Phenylurea, Strobilurin, and Triazine Pesticides by GCxGC-TOFMS Using Rxi-5Sil MS and Rtx-200
rxi-5sil
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Black Seedless Grapes Using Rxi-5Sil MS and Rtx-200
rxi-5sil
Pesticides on Sweet Potato With and Without QuEChERS dSPE Cleanup on Rxi-5Sil MS
rxi-5sil
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
rxi-5sil
Pesticides in Dietary Supplements (Zoom of GCxGC-TOFMS Contour Plot)
rxi-5sil
GC Potency Analysis for Marijuana on Rxi-5Sil MS
rxi-5sil
Sample and Reference Mass Spectra for Incurred Cypermethrin in a QuEChERS Extract of Marijuana by GCxGC on Rxi-5Sil MS and Rtx-200
rxi-5sil
Incurred Cypermethrins in a QuEChERS Extract of Marijuana by GCxGC on Rxi-5Sil MS and Rtx-200
rxi-5sil
Incurred Cypermethrins in a QuEChERS Extract of Marijuana by GCxGC on Rxi-5Sil MS and Rtx-200
rxi-5sil
Tebuthiuron in a QuEChERS Extract of Marijuana by GCxGC on Rxi-5Sil MS and Rtx-200
rxi-5sil
Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200
rxi-5sil
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
rxi-5sil
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
rxi-5sil
Comparison of 2,4-Dinitrophenol response with Semivolatiles wool and MS Certified wool
rxi-5sil
Pesticides in Dietary Supplements (GCxGC-TOFMS Contour Plot)
rxi-5sil
Dandelion Root QuEChERS Extract Cleaned with Cartridge SPE (GCxGC-TOFMS Contour Plot)
rxi-5sil
Sage QuEChERS Extract Cleaned with Cartridge SPE (GCxGC-TOFMS Contour Plot)
rxi-5sil
Dietary Supplement (Finished Product) QuEChERS Extract Cleaned with Cartridge SPE (GCxGC-TOFMS Contour Plot)
rxi-5sil
Sage QuEChERS Extract Cleaned with Cartridge SPE (Zoom of GCxGC-TOFMS Contour Plot)
rxi-5sil
Hexachlorocyclohexanes in Sage QuEChERS Extract (Zoom of GCxGC-TOFMS Contour Plot)
rxi-5sil
Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.
rxi-5sil
Cocaine and Metabolites (TMS Derivatives) on Rxi-5Sil MS (100 ng/mL)
rxi-5sil
Extracted Opiates from Blood on Rxi-5Sil MS
rxi-5sil
Polycyclic Aromatic Hydrocarbons Infant Formula With and Without QuEChERS dSPE Cleanup on Rxi-5Sil MS
rxi-5sil
Polycyclic Aromatic Hydrocarbons Infant Formula with and without QuEChERS dSPE Clean-up on Rxi-5Sil MS
rxi-5sil
Dioxins (TCDDs) in Fly Ash on Rxi-5Sil MS column
rxi-5sil
Furans (TCDFs) in Fly Ash on Rxi-5Sil MS
rxi-5sil
Dioxins (PnCDDs) in Fly Ash on Rxi-5Sil MS
rxi-5sil
Dioxins (HxCDFs) in Fly Ash on Rxi-5Sil MS
rxi-5sil
Comparison of Strawberry Extracts (TICs) Processed with Different QuEChERS dSPE Sorbents on Rxi-5Sil MS
rxi-5sil
Comparison of Spinach Extracts (TICs) Processed with Different QuEChERS dSPE Sorbents on Rxi-5Sil MS
rxi-5sil
Extracted Ion Chromatograms and Spectra for Incurred Pesticides in Strawberries on Rxi-5Sil MS
rxi-5sil
Uber Test Mix on Rxi-5Sil MS
rxi-5sil
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
rxi-5sil
Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS
rxi-5sil
Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS
rxi-5sil
Column Test Mix on Rxi-5Sil MS
rxi-5sil
Rxi-5Sil MS Competitor Bleed Comparison
rxi-5sil
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
rxi-5sil
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
rxi-5sil
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
rxi-5sil
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
rxi-5sil
dSPE vs. cSPE Sample Cleanup of Dandelion Root Powder (Dietary Supplement) on Rxi-5Sil MS
rxi-5sil
Carfentrazone Ethyl in Dandelion Root Powder (Dietary Supplement) on Rxi-5Sil MS
rxi-5sil
Derivatized Amphetamines (500 ng/mL) on Rxi-5Sil MS
rxi-5sil
Derivatized Cannabinoids (5 μg/mL) on Rxi-5Sil MS
rxi-5sil
Derivatized Cannabinoids (50 ng/mL) on Rxi-5Sil MS
rxi-5sil
Derivatized Amphetamines (50 ng/mL) on Rxi-5Sil MS
rxi-5sil
Benzodiazepines (15 μg/mL) on Rxi-5Sil MS
rxi-5sil
Analysis of Melamine and Related Compounds on Rxi-5Sil MS
rxi-5sil
Analysis of Melamine and Related Compounds in Infant Formula on Rxi-5Sil MS
rxi-5sil
Batch-to-Batch Reproducibility of Rxi-5Sil MS
rxi-5sil
QuEChERS Extracts of Tylenol with Different dSPE Cleanups on Rxi-5Sil MS
rxi-5sil
QuEChERS Extracts of Tylenol Spiked with Anisoles and TBA on Rxi-5Sil MS
rxi-5sil
Mass Spectra of Pentachloroanisole QuEChERS Extracts of Tylenol Spiked with Anisoles and TBA on Rxi-5Sil MS
rxi-5sil
Polycyclic Aromatic Hydrocarbons Rxi-5Sil MS
rxi-5sil