Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Current Filters

  • Chromatogram Type
    GC
  • Detector Type
    FID
  • Injector Type
    Split

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
  • 1,4-dioxane
  • 123-91-1, pyrene and chrysene
  • semivolatiles and rxi5silms
  • 8270
Isophorone Purity Analysis (ASTM D7090) on Rtx-Wax
GC_PC1369
Methyl Isobutyl Ketone (MIBK) Purity Analysis (ASTM D3329) on Stabilwax
GC_PC1373
Phenols in Cresylic Acid (ASTM D5310) on Rxi-5ms
GC_PC1371
Cannabinoid Neutrals Mix on Rxi-35Sil MS
GC_GN1208
Solvents on Rt-U-BOND
GC_PC1370
Aliphatic Amines on Stabilwax-DB
GC_PC1361
Selectivity of Rt-BOND Porous Polymer PLOT Columns (C1-C2 Hydrocarbons)
GC_PC1360
Sunflower Oil on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)
GC_FF1344
Cocoa Butter on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)
GC_FF1345
Food Industry FAMEs on Rt-2560 by AOCS Method Ce-1h-05
GC_FF1349
Food Industry FAMEs on Rt-2560 by AOCS Method Ce-1j-07 Using H2 (Optimized Method)
GC_FF1348
Food Industry FAMEs on Rt-2560 by AOCS Method Ce-1j-07 using H2 (Original Method)
GC_FF1347
Palm Oil on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)
GC_FF1342
Food Industry FAMEs on Rt-2560 by AOAC Method 996.06 Using H2
GC_FF1346
Extra Virgin Olive Oil on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)
GC_FF1343
Citronella Java Oil on Rtx-Wax
GC_FF1296
Bergamot Oil on Rtx-Wax
GC_FF1297
Eucalyptus Oil on Rtx-Wax
GC_FF1298
Patchouli Oil on Rtx-Wax
GC_FF1300
Lavender Oil on Rtx-Wax
GC_FF1301
Peppermint Oil on Rtx-Wax
GC_FF1302
Grapefruit Oil on Rtx-Wax
GC_FF1303
Tea Tree Oil on Rtx-Wax
GC_FF1304
Geranium Oil on Rtx-Wax
GC_FF1305
Lemongrass Oil on Rtx-Wax
GC_FF1306
Lemon Oil on Rtx-Wax
GC_FF1307
Rosemary Oil on Rtx-Wax
GC_FF1299
trans-Fats in Frosting on Rt-2560
GC_FS0567
Impurities in Commercial Cyclohexane on Rtx-DHA-100
GC_PC1356
Cumene (Isopropylbenzene) on Rtx-1
GC_PC1350
Impurities in α-Methylstyrene on Rtx-1
GC_PC1351
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
GC_PC1355
Impurities in p-Xylene on Stabilwax
GC_PC1354
Styrene on Stabilwax
GC_PC1352
Ethylbenzene on Stabilwax
GC_PC1353
Cocoa Butter on Rxi-65TG
GC_FF1295
Sunflower Oil on Rxi-65TG
GC_FF1294
Extra Virgin Olive Oil on Rxi-65TG
GC_FF1293
Palm Oil on Rxi-65TG
GC_FF1292
Rxi-65TG: High-Temperature Stability Overlay
GC_FF1287
Citrals on Rtx-Wax
GC_FF1280
Hydrocarbon Gases on Rt-Q-BOND
GC_PC1340
Refinery Gas on Rt-Q-BOND
GC_PC1342
Hydrocarbon Gases on Rt-Q-BOND
GC_PC1339
Marine Oil FAMEs on FAMEWAX
GC_FF00566
Margarine on Rtx-2330
GC_FF1268
Margarine on Rt-2560
GC_FF1269
Shortening on Rt-2560
GC_FF1275
Shortening on Rtx-2330
GC_FF1276
Butter Flavored Popcorn on Rtx-2330
GC_FF1271
Butter Flavored Popcorn on Rt-2560
GC_FF1272
Petroleum Hydrocarbons (TPH) on Rxi-1ms
GC_EV00886
TNRCC 1006 Retention Time Marker Mix on Rxi-5Sil MS
GC_EV1492
Diesel Fuel #2 Standard on Rxi-5Sil MS by Split Injection
GC_EV1491
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
GC_EV1490
MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
GC_EV1487
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
GC_EV1488
NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
GC_EV1489
trans Fat Reference Standard on Rt-2560
GC_FF1267
Olive Oil FAMEs on Stabilwax
GC_FF1265
Palm Oil FAMEs on Stabilwax
GC_FF1266
Unsaturated cis/trans FAMEs on Rt-2560
GC_FF1264
FAME in Soy B100 by EN 14103 (2011)
GC_PC1333
Food Industry FAME on FAMEWAX by EN14103 (2011)
GC_PC1332
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
GC_PC1330
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
GC_PC1310
Naphthenes on Rtx-DHA-100 (ASTM D6729-14)
GC_PC1325
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
GC_PC1326
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
GC_PC1309
Olefins on Rtx-DHA-100 (ASTM D6729-14)
GC_PC1324
Isoparaffins on Rtx-DHA-100 (ASTM D6729-14)
GC_PC1322
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
GC_PC1323
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
GC_PC1327
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
GC_PC1328
ASTM D5134 Rtx-DHA 50 Column Evaluation
GC_PC1318
Alkylate Standard on Rtx-DHA 50 by Method D5134-13
GC_PC1319
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
GC_PC1320
Comparison of Glycols Before and After 600 Water Injections on Rtx-Wax
GC_EV1454
Unsaturated FAMES QC Test Mix on Rt-2560
GC_QA0099
Nutritional Labeling FAMEs on Rt-2560 by AOCS Method Ce-1j-07
GC_FF1262
Nutritional Labeling FAMEs on Rt-2560 by AOAC Method 996.06
GC_FF1261
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
GC_PC1284
Electronic Cigarette Liquid on Rtx-VMS (Hydrogen)
GC_FF1259
Electronic Cigarette Liquid on Rtx-VMS (Hydrogen/Fast Ramp)
GC_FF1257
Electronic Cigarette Liquid on Rtx-VMS (Helium)
GC_FF1256
Medical Cannabis Cannabinoids and Internal Standards on Rxi-35Sil MS
GC_FS0549
Electronic Cigarette Liquid on Rtx-VMS (Hydrogen)
GC_FF1258
Arabian Medium Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1385
Diesel #2/Motor Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1364
Used Motor Oil Composite Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1365
Creosote Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1367
Creosote Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1368
Diesel #2/Mineral Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1363
DRO/ORO Calibration Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1366
Florida TRPH Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1377
South Louisiana Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1369
Florida Beach Tarball 11 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1372
DRO/ORO Calibration Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1380
Creosote Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1381
Used Motor Oil Composite Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1382
South Louisiana Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1383
Iraqi Basrah Light Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1384
Florida Beach Tarball 11 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1386
Florida Beach Tarball 1 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1387
Florida Beach Tarball 6 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1388
Florida Beach Tarball 9 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1389
Florida Beach Tarball 5 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1390
Diesel #2/Motor Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1379
Diesel #2/Mineral Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1378
Florida Beach Tarball 5 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1376
Florida Beach Tarball 9 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1375
Florida Beach Tarball 6 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1374
Florida Beach Tarball 1 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1373
Arabian Medium Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1371
Iraqi Basrah Light Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1370
Florida TRPH Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
GC_EV1362
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-100 (ASTM D5441)
GC_PC1268
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-150 (ASTM D5441)
GC_PC1269
Cannabinoids in Cannabis Sample 10 on Rxi-35Sil MS
GC_FS0528
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-50 (ASTM D5441)
GC_PC1270
Cannabinoids in Cannabis Sample 94 on Rxi-35Sil MS
GC_FS0527
Cannabinoids in Cannabis Sample 98 on Rxi-35Sil MS
GC_FS0529
Medical Cannabis Terpenes on Rxi-624Sil MS
GC_FS0509
Florida TRPH Standard Mix on Rxi-1HT
GC_PC1272
Terpenes in Kryptonite Medical Cannabis on Rxi-624Sil MS
GC_FS0512
Terpenes in Kryptonite Cannabis on Rxi-624Sil MS
GC_FS0510
Terpenes in Blueberry Jack Cannabis on Rxi-624Sil MS
GC_FS0511
Terpenes in Blueberry Jack Medical Cannabis on Rxi-624Sil MS
GC_FS0513
Terpenes in Kryptonite Medical Cannabis on Rxi-624Sil MS
GC_FS0514
Terpenes in Blueberry Jack Medical Cannabis on Rxi-624Sil MS
GC_FS0515
Cannabis Potency Compounds on Rxi-35Sil MS
GC_FF1248
Cannabis Potency Compounds on Rxi-17Sil MS
GC_FF1247
Cannabis Potency Compounds on Rxi-5Sil MS
GC_FF1253
Cannabinoids on Rxi-35Sil MS Using Hydrogen Carrier Gas by GC-FID
GC_FS0501
Volatile Amine Test Mix on Rtx-Volatile Amine (60 m x 0.32 mm ID)
GC_PC1228
Marine Oil FAMEs on FAMEWAX
GC_FF00572
Neutral Sterols on Rtx-225
GC_FF00431
Aromatics (Benzene/Toluene/Xylene) on MXT-WAX
GC_PC00188
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
GC_PC00190
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
GC_PC00194
Lubricant (Synthetic) on Stabilwax
GC_PC00219
Organic Volatile Impurities on Rtx-5
GC_PH00256
Organic Volatile Impurities on Rtx-1301
GC_PH00257
Reformate on Rtx-1
GC_PC00210
FAMEs PUFA (marine source) on MXT-WAX
GC_FF00116
FAMEs Commercial Margarine Stabilwax
GC_FF00124
Crude Oil, Arabian Light on Rtx-1
GC_PC00232
Crude Oil, Prudhoe Bay on Rtx-1
GC_PC00231
Phenols and Benzidines by U.S. EPA Methods 604 and 605 on Rtx-5
GC_EV00032
Phthalate Esters by U.S. EPA Method 606 on MXT-5
GC_EV00035
Alcohols Rtx-5
GC_CH00292
Alcohols Rtx-Volatiles
GC_CH00293
FAMEs PUFA (menhaden source) FAMEWAX
GC_FF00115
Nitroaromatics by U.S. EPA Method 609 on Rtx-5
GC_EV00041
Silanes on Rtx-200
GC_CH00361
Siloxane (Polysiloxane 20) on MXT-5
GC_CH00359
Siloxane (Polymethyl) on Rtx-200
GC_CH00360
Silanes on Rtx-200
GC_CH00362
Solvents (Nitrogen Containing) on Rtx-1701
GC_CH00330
Glycols on Rtx-200
GC_CH00326
FAMEs (Saw Palmetto) on Stabilwax
GC_FF00367
Stability Overlay: 1st and 40th Injections of Short-Chain Amines in Water on Rtx-Volatile Amine
GC_PC1244
Short-Chain Amines on Rtx-Volatile Amine
GC_PC1243
Impurities in Pyridine on Rtx-Volatile Amine
GC_PC1246
Impurities in Diethylamine on Rtx-Volatile Amine
GC_PC1247
Impurities in Triethylamine on Rtx-Volatile Amine
GC_PC1248
Impurities in Isopropylamine on Rtx-Volatile Amine
GC_PC1249
Separation of Ethanol and Aromatics from Paraffins in Gasoline with GCxGC on Rtx-DHA-150 and Stabilwax
GC_PC1227
p- and m-Xylenes in Gasoline by GCxGC on Rtx-DHA-150 and Stabilwax
GC_PC1226
Acetylene and Propadiene Capacity on Rt-Alumina BOND/MAPD
GC_PC1216
Phenanthrene and Anthracene on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
GC_EV1188
Sulfur Compounds on Rtx-1
GC_PC1222
C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD
GC_PC1213
Glycols on Rtx-BAC Plus 1 and 2 Column Set
GC_CF1163
1,3-Butadiene on Rt-Alumina BOND/MAPD (Purity Analysis)
GC_PC1211
High Molecular Weight Impurity in 1,3-Butadiene on Rt-Alumina BOND/MAPD
GC_PC1212
GC Potency Analysis for Marijuana on Rxi-5Sil MS
GC_GN1156
Crude 1,3-Butadiene on Rt-Alumina BOND/MAPD
GC_PC1202
Volatile Solvents on Rtx-Wax
GC_CH00347
Glycols on Rtx-BAC1 & Rtx-BAC2
GC_EV00474
Unleaded Gasoline on Rtx-1 (Comparison of Unweathered and 99 Weathered)
GC_MS00270
Light Hydrocarbons on Rt-Alumina BOND/MAPD
GC_PC1201
Solvents on Rt-QS-BOND
GC_PC01021
Styrene Impurities on Stabilwax
GC_CH00356
Solvents on Rtx-5
GC_CH00346
Solvents on Stabilwax
GC_CH00345
Amine Test Mix Rtx-35 Amine
GC_CH00577
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
GC_PH1150
Amphetamine and Methamphetamine with salt and free base forms on Rtx-5MS
GC_PH00973
Amphetamine and Methamphetamine in free base form on Rtx-5MS
GC_PH00974
Amphetamine and Methamphetamine (HFAA derivatized) on Rtx-5MS
GC_PH00975
Amphetamine and Methamphetamine (HFAA derivatized) with clean-up on Rtx-5MS
GC_PH00976
E85 Fuel Ethanol by ASTM D5501 on Rtx-DHA-150
GC_PC1144
Gasoline Light Fractions on Rtx-DHA-150
GC_PC1145
Light Hydrocarbons on Rtx-DHA-150
GC_PC1146
Natural Gas (82 Methane) on Rtx-DHA-150
GC_PC1147
m- and p-Xylene on Rtx-DHA-150
GC_PC1148
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
GC_PC01139
The combination of high-purity gas and gas purifying traps can save analytical time in the long run
GC_EX00391
Rum on Rtx-1301
GC_FF00110
Scotch on Rtx-1301
GC_FF00112
Example of Vial Cap or Injection Port Septum Bleed
GC_EX00980
FAMEs (Marine Oil Standard) on FAMEWAX
GC_FF00499
Flavor Volatiles on Rtx-1
GC_FF00536
Flavor Volatiles on Stabilwax
GC_FF00537
FAMEs (Polyunsaturated Fatty Acids, Animal Source) on MXT-WAX
GC_FF00117
FAMEs (Saw Palmetto) on Rtx-Wax
GC_FF00538
FAMEs (Ocean Nutrition Sample) on FAMEWAX
GC_FF00568
FAMEs (Polyunsaturated Fatty Acids, Animal Source) on Rtx-2330
GC_FF00119
Personal Care Product Fragrances on Rtx-1
GC_FF00633
FAMEs (Cocoa Butter) on Stabilwax
GC_FF00120
Cleaning Solvents on Rtx-Wax
GC_FF00644
Cleaning Solvents (All-Purpose Cleaner) on Rtx-VMS
GC_FF00646
Cleaning Solvents (Glass Cleaner) on Rtx-VMS
GC_FF00647
Sugars (Alditol Acetates) on Rtx-225
GC_FF00128
Lemon Oil on Rtx-5
GC_FF00138
Mineral Spirits on Rxi-1ms
GC_PC01066
FAMEs (NLEA Mix) on Rt-2560
GC_FF00651
Amines & Phenols on Rtx-5 Amine
GC_CH00301
Polycyclic Aromatic Hydrocarbons on Rxi-17 (15m x 0.25mm x 0.25µm)
GC_EV1181
Phenanthrene and Anthracene on Rxi-17 (15m x 0.25mm x 0.25µm)
GC_EV1183
5 Fragrance Materials Association Mix on Rtx-1
GC_FF00657
Benzofluoranthenes on Rxi-17 (15m x 0.25mm x 0.25µm)
GC_EV1185
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
GC_EV1186
5 Fragrance Materials Association Mix on Rtx-1701
GC_FF00658
Amines/Alcohols/Chlorides on Stabilwax
GC_CH00307
Freon 12 and Ethylene Oxide on Rtx-1
GC_CH00324
Benzofluoranthenes on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
GC_EV1189
Isothermal Test Mix on Rxi-5ms
GC_EV00819
Styrene Impurities Rtx-1701
GC_CH00357
Primary Amines on Rtx-35 Amine
GC_CH00578
Rxi-5ms columns have the lowest bleed among all major brands of columns.
GC_EV00822
99 Weathered Unleaded Gasoline on Rxi-1ms
GC_PC01070
Unleaded Gasoline on Rxi-1ms
GC_PC01071
An Rxi-5ms column provides the most symmetric peak for the basic compound pyridine
GC_EV00857
Lubrication Range Organics Diesel Fuel #2/Motor Oil on Rxi-1ms
GC_EV00887
Underivatized Cholesterol on Rxi-5ms (Temp. program)
GC_FF00881
Derivatized Cholesterol on Rxi-5ms (Temp. Program)
GC_FF00883
Ethylene Purity Analysis using ASTM D6159-97
GC_PC01109
Short Chain Amines in Water on Rtx-Volatile Amine
GC_GN1154
Propane Camping Fuel on Rt-Alumina BOND/KCl
GC_PC01087
Petroleum Oxygenates on Rt-TCEP
GC_PC00195
Bleed Comparison of Rxi-624Sil MS and VF-624ms
GC_GN1147
Impurity Analysis of 1,1,1,2-Tetrafluoroethane (CFC-134a) on Rt-Alumina BOND/CFC
GC_GN1155
Aromatics on Rt-TCEP
GC_PC00211
Inertness Comparison (Basic Compounds): Primary, Secondary, and Tertiary Amines on Rxi-624Sil MS
GC_PH1162
Calibration: Isopropylamine (5-100 ng on-column) on Rxi-624Sil MS
GC_PH1163
Refinery Gas on Rt-Alumina BOND/KCl
GC_PC01088
Phenols by EPA Method 604 on Rtx-5
GC_EV00030
Restek PLOT Column Technology Assures Stable Performance Even After 500 Pressure Cycles
GC_MS01141
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4
GC_PC01142
Uber Test Mix on Rxi-5Sil MS
GC_CH01097
Detailed Hydrocarbon Analysis on Rtx-DHA-100/Rtx-5 DHA Tuning Column
GC_PC00743A
Propane Camping Fuel on Rt-Alumina BOND/Na2SO4
GC_PC01084
Butane Lighter Fluid on Rt-Alumina BOND/Na2SO4
GC_PC01083
Natural Gas on Rt-Alumina BOND/KCl
GC_PC01091
Natural Gas on Rt-Alumina BOND/Na2SO4
GC_PC01092
Detailed Hydrocarbons Analysis Rtx-DHA-100
GC_PC00743
Column Comparison: Limit of Ethylene Glycol and Diethylene Glycol in Propylene Glycol
GC_PH1151
Cocaine and Cocaine Adulterants Rtx-440
GC_PH00769
Refinery Gas on MXT-Alumina BOND/Na2SO4
GC_PC1183
γ-Butyrolactone & 1,4-Butanediol Rtx-BAC1 and Rtx-BAC2 (dual column)
GC_PH00808
Solvents on MXT-Q-BOND
GC_PC1184
MXT-Q-BOND Columns are Highly Stable; Pressure Pulsing does not Create Particles or Alter Retention Times
GC_PC1186
Local Anesthetics Rxi-5ms
GC_PH00860
Organic Volatile Impurities Rtx-200 & Rtx-WAX (GC xGC)
GC_PH00888
Stability Test: Halogenated Hydrocarbons on Rt-Alumina BOND/CFC (Before & After 16 hrs. at 200 °C)
GC_PC1192
Halogenated Hydrocarbons on Rt-Alumina BOND/CFC
GC_PC1193
Chlorofluorocarbons (CFCs) on Rt-Alumina BOND/CFC
GC_PC1199
50 Weathered Diesel Fuel #2 on Rxi-1ms
GC_PC00921
Unweathered Diesel Fuel #2 on Rxi-1ms
GC_PC00922
Solvents on Polar Rt-QPLOT
GC_PC00181
Natural Gas #2 on Rt-QS-BOND
GC_PC01013
Underivatized Thalidomide on Rt-βDEXcst
GC_PH00243
Column Test Mix on Rxi-5Sil MS
GC_CF01131
Refinery Gas #6 on Rt-QS-BOND
GC_PC01014
Rxi-5Sil MS Competitor Bleed Comparison
GC_EV01008
Underivatized Antihistamines (Basic Drugs) on Rtx-5 Amine
GC_PH00247
Ketones on Rt-QS-BOND
GC_PC01015
Refinery Gas Mix on Rt-QS-BOND
GC_PC01054
Spearmint Oil (Native ) on Stabilwax
GC_FF00140
Unweathered Kerosene on Rxi-1ms
GC_PC01060
Peppermint Oil on MXT-WAX
GC_FF00141
Bleed Profiles of 5HT Columns
GC_GN1144
Mushroom Aroma (Synthetic) on Stabilwax
GC_FF00143
Q, QS, S, and U PLOT Column Comparison
GC_PC01074
Lemon Oil on Rt-βDEXsm
GC_FF00146
Rosemary Oil on Rt-βDEXsm
GC_FF00147
Geranium Oil (Commercial) on Rt-βDEXsa
GC_FF00148
Menthol on Rt-βDEXsp
GC_FF00149
Irone Isomers on Rt-βDEXcst
GC_FF00150
Phencyclidine on Rtx-5
GC_PH00234
1-Octen-3-ol and Carvone on Rt-βDEXsa
GC_FF00151
Underivatized Mixed Basic Drugs on Rtx-5
GC_PH00235
γ-Lactones on Rt-βDEXcst
GC_FF00152
Underivatized Mixed Basic Drugs on Rtx-200
GC_PH00237
β-Citronellol on Rt-βDEXsa
GC_FF00153
DHA Column Inertness Comparison Using Oxy Setup
GC_PC01098
Cocaine & Metabolites (TMS Derivatives) on Rtx-5
GC_PH00254
δ-Lactones on Rt-βDEXcst
GC_FF00154
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
GC_PC01110
Steroids, Anabolic (Underivatized) on Rtx-5
GC_PH00255
Apple Juice with Standards on Rt-βDEXse
GC_FF00157
Refinery Gas on Rt-Alumina BOND (Na2SO4)
GC_PC01085
Apple Juice on Rt-βDEXse
GC_FF00158
Grape Juice Extract on Rt-γDEXsa
GC_FF00159
Solvent Mixture on Rt-Q-BOND
GC_PC01082
Solvent Mixture on Rt-QS-BOND
GC_PC01081
Solvent Mixture on Rt-S-BOND
GC_PC01080
FAMEs (Evening Primrose Oil) on FAMEWAX
GC_FF00363
Underivatized Ibuprofen on Rt-βDEXsm
GC_PH00242
FAMEs (Flax Seed Oil) on FAMEWAX
GC_FF00364
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
GC_PC00774
FAMEs (Black Currant Seed Oil) on FAMEWAX
GC_FF00365
FAMEs (Borage Seed Oil) on FAMEWAX
GC_FF00366
Underivatized Antidepressants (Basic Drugs) on Rtx-1701
GC_PH00264
Antiepileptics (Underivatized) on Rtx-20
GC_PH00265
Antiepileptics (Underivatized) on Rtx-1701
GC_PH00266
Underivatized Phenothiazines (Basic Drugs) on Rtx-5
GC_PH00269
Batch-to-Batch Reproducibility of Rxi-5Sil MS
GC_GN0050
Soy FAMEs in Biodiesel Oils on Stabilwax
GC_PC00915
Tallow FAMEs in Biodiesel Oils on Stabilwax
GC_PC00916
Rapeseed FAMEs in Biodiesel Oils on Stabilwax
GC_PC00917
Cleaning Solvents on Rtx-VMS
GC_FF00645
Yellow Grease FAMEs in Biodiesel Oils on Stabilwax
GC_PC00918
Fatty Acids (Free) on Stabilwax-DA (30m, 0.25mm ID, 0.25µm)
GC_CH00280
Fatty Acids (Free) on Rtx-200
GC_CH00282
Underivatized Cold Medications (Basic Drugs) on Rtx-5 Amine
GC_PH00469
Underivatized Cholesterol on Rxi-5ms (Isothermal)
GC_FF00882
Phenols by EPA Method 604 on Rtx-200
GC_EV00028
Derivatized Cholesterol on Rxi-5ms (Isothermal)
GC_FF00884
Ethanolamines on Rtx-5 Amine
GC_CH00296
Ethyleneamines on Rtx-5 Amine
GC_CH00298
Fragrance Allergens on Rxi-1ms & Rxi-17 (GC x GC)
GC_FF01010
Benzodiazepines (Underivatized) on Rtx-200
GC_PH00268
Underivatized Mixed Basic Drugs on Rtx-35
GC_PH00236
Barbiturates (Acidic/Neutral Drugs) (Underivatized) on Rtx-35
GC_PH00267
Glycerides and Cholesterol in Extracted Egg Fats on Rtx-65TG
GC_FF01045
Cresylic Acids on Stabilwax-DA
GC_CH00277
Flavor & Fragrance Compounds Rt-CW20M F&F
GC_FF00433