Chlorofluorocarbons on Rtx-1

GC_CH00319
Peaks
1.Freon® 22
2.Freon® 12
3.Freon® 114
4.Freon® 1112a
5.Freon® 123
6.Freon® 123a
7.Freon® 11
8.Freon® 113
9.Freon® 122
ColumnRtx-1, 105 m, 0.25 mm ID, 1.00 µm (cat.# 10159)
Sample99.9% pure Freon 113 standard
Injection
Inj. Vol.:1.0 µL split
Inj. Temp.:250 °C
Split Vent Flow Rate:30 mL/min
Oven
Oven Temp.:35 °C (hold 20 min) to 220 °C at 20 °C/min (hold 30 min)
Carrier GasHe, constant flow
Linear Velocity:20 cm/sec @ 35 °C
DetectorMS
Mode:Scan
Source Temp.:250 °C