Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms

GC_EV1507
PeakstR (min)
1.1,4-Dioxane3.494
2.N-Nitrosodimethylamine3.874
3.Pyridine3.943
4.Ethyl methacrylate4.497
5.2-Picoline4.945
6.N-Nitrosomethylethylamine5.074
7.Acrylamide5.427
8.Methyl methanesulfonate5.511
9.N-Nitrosodiethylamine6.127
10.Ethyl methanesulfonate6.579
11.Benzaldehyde7.174
12.Phenol7.238
13.Aniline7.342
14.Bis(2-chloroethyl) ether7.434
15.Pentachloroethane7.448
16.2-Chlorophenol7.55
17.Decane7.623
18.1,3-Dichlorobenzene7.832
19.1,4-Dichlorobenzene7.957
20.Benzyl alcohol8.132
21.1,2-Dichlorobenzene8.227
22.2-Methylphenol8.314
23.Indene8.384
24.2,2'-oxybis(1-chloropropane)8.384
25.N-Nitrosopyrrolidine8.571
26.4-Methylphenol8.583
27.3-Methylphenol8.583
28.N-Nitrosodi-N-propylamine8.618
29.Acetophenone8.625
30.N-Nitrosomorpholine8.644
31.o-Toluidine8.689
32.Hexachloroethane8.845
33.Nitrobenzene8.941
34.N-Nitrosopiperidine9.211
35.Isophorone9.377
36.2-Nitrophenol9.532
37.2,4-Dimethylphenol9.582
38.Benzoic acid9.693
39.O,O,O-Triethyl phosphorothioate9.723
40.Bis(2-chloroethoxy)methane9.777
41.2,4-Dichlorophenol9.976
42.Phentermine10.099
43.1,2,4-Trichlorobenzene10.156
44.Naphthalene10.313
45.α-Terpineol10.315
46.4-Chloroaniline10.939
47.2,6-Dichlorophenol10.414
48.Hexachloropropene10.481
49.Hexachlorobutadiene10.546
50.Quinoline10.943
PeakstR (min)
51.Caprolactam11.029
52.N-Nitrosodibutylamine11.047
53.1,4-Phenylenediamine11.067
54.4-Chloro-3-methylphenol11.312
55.Isosafrole I11.472
56.2-Methylnaphthalene11.653
57.1-Methylnaphthalene11.846
58.Hexachlorocyclopentadiene11.963
59.1,2,4,5-Tetrachlorobenzene11.98
60.Isosafrole II12.045
61.2,3-Dichloroaniline12.191
62.2,4,6-Trichlorophenol12.191
63.2,4,5-Trichlorophenol12.256
64.Safrole12.492
65.Biphenyl12.57
66.2-Chloronaphthalene12.61
67.1-Chloronaphthalene12.655
68.Diphenyl ether12.778
69.2-Nitroaniline12.793
70.1,4-Naphthoquinone12.946
71.1,2-Dinitrobenzene13.063
72.Dimethyl phthalate13.162
73.1,3-Dinitrobenzene13.209
74.2,6-Dinitrotoluene13.274
75.1,4-Dinitrobenzene13.372
76.Acenaphthylene13.431
77.3-Nitroaniline13.6
78.Acenaphthene13.775
79.2,4-Dinitrophenol13.808
80.4-Nitrophenol13.904
81.Pentachlorobenzene14.038
82.2,4-Dinitrotoluene14.073
83.Dibenzofuran14.118
84.1-Naphthylamine14.265
85.2,3,5,6-Tetrachlorophenol14.266
86.2,3,4,6-Tetrachlorophenol14.35
87.2-Naphthylamine14.422
88.Diethyl Phthalate14.57
89.Hexadecane14.622
90.Zinophos14.729
91.Fluorene14.801
92.4-Chlorophenyl phenyl ether14.803
93.5-Nitro-O-toluidine14.806
94.4-Nitroaniline14.812
95.4,6-Dinitro-2-methylphenol14.879
96.Diphenylamine15.028
97.Azobenzene15.116
98.Sulfotep15.349
99.1,3,5-Trinitrobenzene15.523
100.Phorate15.63
PeakstR (min)
101.Phenacetin15.631
102.Diallate15.634
103.4-Bromophenyl phenyl ether15.776
104.Hexachlorobenzene15.896
105.Dimethoate15.948
106.Atrazine16.089
107.4-Aminobiphenyl16.284
108.Pentachloronitrobenzene16.277
109.Pentachlorophenol16.311
110.Propyzamide16.408
111.Octadecane16.468
112.Dinoseb16.648
113.Disulfoton16.673
114.Phenanthrene16.716
115.Anthracene16.819
116.Carbazole17.128
117.Methyl parathion17.41
118.di-n-Butyl phthalate17.837
119.Ethyl parathion18.191
120.4-Nitroquinoline N-oxide18.239
121.Methapyrilene18.413
122.Isodrin18.794
123.Fluoranthene19.087
124.Benzidine19.341
125.Pyrene19.539
126.Aramite I19.813
127.Aramite II19.965
128.p-(Dimethylamino)azobenzene20.128
129.Chlorobenzilate20.224
130.Famphur20.711
131.3,3'-Dimethylbenzidine20.803
132.Benzyl butyl phthalate20.842
133.Kepone20.924
134.Bis(2-ethylhexyl) adipate21.02
135.2-(Acetylamino)fluorene21.345
136.3,3'-Dichlorobenzidine22.042
137.4,4-Methylene-bis(2-chloroaniline)22.054
138.Benz[a]anthracene22.11
139.Chrysene22.201
140.Bis(2-ethylhexyl) phthalate22.209
141.6-Methylchrysene23.411
142.Di-n-octyl phthalate24.047
143.Benzo[b]fluoranthene25.155
144.7,12-Dimethylbenz[a]anthracene25.147
145.Benzo[k]fluoranthene25.243
146.Benzo[a]pyrene26.197
147.3-Methylcholanthrene27.396
148.Dibenz(a,h)acridine29.284
149.Dibenz[a,j]acridine29.458
150.Indeno[1,2,3-cd]pyrene30.064
151.Dibenz[a,h]anthracene30.162
152.Benzo[ghi]perylene30.987
ColumnRxi-SVOCms, 30 m, 0.25 mm ID, 0.50 µm (cat.# 16638)
Standard/SampleSVOC MegaMix 150 kit (cat.# 31907)
Diluent:Dichloromethane
Conc.:20 µg/mL (2 ng on-column)
Injection
Inj. Vol.:1 µL split (split ratio 10:1)
Liner:Topaz 4.0 mm ID single taper inlet liner w/ wool (cat.# 23303)
Inj. Temp.:250 °C
Oven
Oven Temp.:40 °C (hold 1 min) to 280 °C at 12.4 °C/min to 330 °C at 3.3 °C/min (hold 3.65 min)
Carrier GasHe, constant flow
Flow Rate:1.2 mL/min
DetectorMS
Mode:Scan
Scan Program:
GroupStart Time
(min)
Scan Range
(amu)
Scan Rate
(scans/sec)
12.050-5003.6
Transfer Line Temp.:280 °C
Analyzer Type:Quadrupole
Source Type:Inert
Drawout Plate:6 mm ID
Source Temp.:330 °C
Quad Temp.:180 °C
Electron Energy:70 eV
Solvent Delay Time:2 min
Tune Type:DFTPP
Ionization Mode:EI
InstrumentAgilent 7890A GC & 5975C MSD
Sample PreparationSolutions were mixed and diluted to 20 ppm with dichloromethane in amber 2 mL, 9 mm short-cap, screw-thread vials (cat.# 21143) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (cat.# 23842).
NotesThe SVOC MegaMix 150 kit (cat.# 31907) contains one ampul each of the following standards.
• 8270 MegaMix (cat.# 31850)
• SVOC Additions standard (cat.# 31909)
• Appendix IX mix #1, revised (cat.# 32459)
• Methapyrilene (cat.# 32460)
• Appendix IX mix #2 (cat.# 31806)
• Benzoic acid (cat.# 31879)
AcknowledgementChris Rattray