Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.
Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Analgesics and Non-Steroidal Anti-Inflamatory Drugs (NSAID) on Raptor Biphenyl by LC-MS/MS

LC_CF0620
PeakstR (min)Conc.
(ng/mL)
Precursor IonProduct IonProduct IonESI Polarity
1.Acetaminophen1.19100152.293.065.0Positive
2.Tenoxicam2.26100338.1121.095.0Positive
3.Etoricoxib2.84100359.2280.0279.2Positive
4.Lornoxicam3.08200373.1121.195.0Positive
5.Ketorolac3.22100256.1104.977.0Positive
6.Piroxicam3.26100332.195.278.1Positive
7.Loxoprofen3.41100245.083.280.9Negative
8.Tolmetin3.64100258.1119.191.0Positive
9.Sulindac3.83100357.2233.1248.0Positive
10.Ketoprofen4.00100253.0209.0--Negative
11.Naproxen4.05200229.0168.9184.9Negative
12.Salsalate4.05100256.8136.892.9Negative
13.Meloxicam4.22100352.1115.0141.0Positive
14.Etodolac4.80100286.0241.9212.0Negative
15.Fenoprofen4.84200240.992.8--Negative
16.Oxaprozin4.86200292.0219.8102.0Negative
17.Ibuprofen4.92200205.0160.9--Negative
18.Flurbiprofen4.99100243.0199.0196.8Negative
19.Parecoxib5.20200371.2234.0165.1Positive
20.Nabumetone5.23100229.1171.1128.1Positive
21.Diclofenac5.46100293.9249.8--Negative
22.Indomethacin5.60100356.0311.8296.9Negative
23.Flufenamic acid5.75100279.9236.1176.2Negative
24.Celecoxib5.90200382.2362.0300.1Positive
25.Mefenamic acid5.91100242.1224.1--Positive
26.Tolfenamic acid6.21100259.9215.8--Negative
27.Meclofenamic acid6.29200293.9257.8177.7Negative
ColumnRaptor Biphenyl (cat.# 9309A12)
Dimensions:100 mm x 2.1 mm ID
Particle Size:2.7 µm
Guard Column:Raptor Biphenyl EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9309A0252)
Temp.:30 °C
Sample
Diluent:Water
Inj. Vol.:5 µL
Mobile Phase
A:Water + 0.1% formic acid + 5 mM ammonium formate
B: (95:5) Acetonitrile:water + 0.1% formic acid + 5 mM ammonium formate
Time (min)Flow (mL/min)%A%B
0.000.6955
1.000.67030
6.500.64060
6.510.6955
8.500.6955
DetectorMS/MS
Ion Mode:ESI+/ESI-
Mode:Scheduled MRM
InstrumentUHPLC
Notes1. Positive and negative polarity was collected simultaneously from a single injection.
2. Oxaprozin displays enhanced sensitivity using positive polarity.