Restek Super Clean Gas Filter Kits

  • High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
  • Designed for easy, hassle-free cartridge changes.
  • Glass inside to prevent diffusion, polycarbonate housing outside for safety.
  • The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.
Documentation and Instructions Sheets

Restek Super Clean Gas Filter Kits

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
21983 kit 1/8" Brass Helium-Specific Carrier Gas Cleaning Kit Select Deselect

Catalog # 21983

Units
kit  
Fittings
1/8" Brass  
Includes
Mounting Baseplate; 1/8" Inlet/Outlet Fittings; and Oxygen/Moisture/Hydrocarbon Helium-Specific Filter  
Product Name
Helium-Specific Carrier Gas Cleaning Kit  
Similar To
Agilent 5188-6475
22019 kit 1/8" Brass Carrier Gas Cleaning Kit Select Deselect

Catalog # 22019

Units
kit  
Fittings
1/8" Brass  
Includes
Mounting Baseplate; 1/8" Inlet/Outlet Fittings; and Oxygen/Moisture/Hydrocarbon Triple Gas Filter  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Carrier Gas Cleaning Kit  
Similar To
Agilent 5182-9704
22021 kit 1/8" Brass Fuel Gas Purification Kit Select Deselect

Catalog # 22021

Units
kit  
Fittings
1/8" Brass  
Includes
Mounting Baseplate, 1/8" Inlet/Outlet Fittings, and Hydrocarbon/Moisture Fuel Gas Filter  
Product Name
Fuel Gas Purification Kit  
22031 kit Gas Filter Bundle Kit Select Deselect

Catalog # 22031

Units
kit  
Includes
Triple Gas Filter (1), (cat.# 22020); and Fuel Gas Filters (2), (cat.# 22022)  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Gas Filter Bundle Kit  
Similar To
Agilent 5183-4769
23844 kit 1/4" Brass Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit Select Deselect

Catalog # 23844

Units
kit  
Fittings
1/4" Brass  
Used with
Ideal for TOC analyzers and zero air generators.  
Includes
Replacement CO2, Sulfur, Moisture Filter, Baseplate with 1/4" Brass Fittings  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit  
23845 kit 1/8" Brass Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit Select Deselect

Catalog # 23845

Units
kit  
Fittings
1/8" Brass  
Used with
Ideal for TOC analyzers and zero air generators.  
Includes
Replacement CO2, Sulfur, Moisture Filter, Baseplate with 1/8" Brass Fittings  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit  
23846 kit 1/4" Stainless Steel Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit Select Deselect

Catalog # 23846

Units
kit  
Fittings
1/4" Stainless Steel  
Used with
Ideal for TOC analyzers and zero air generators.  
Includes
Replacement CO2, Sulfur, Moisture Filter, Baseplate with 1/4" Stainless Steel Fittings  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit  
23847 kit 1/8" Stainless Steel Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit Select Deselect

Catalog # 23847

Units
kit  
Fittings
1/8" Stainless Steel  
Used with
Ideal for TOC analyzers and zero air generators.  
Includes
Replacement CO2, Sulfur, Moisture Filter, Baseplate with 1/8" Stainless Steel Fittings  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Super Clean Combi (CO2, Sulfur, Moisture) Filter Kit  

Specifications for Super Clean Gas Filters

Restek Super Clean Traps measure: 10 5/8" x 1 3/4" (27 x 4.4 cm).

          -----Capacity------  
Type of Filter Outlet Gas Quality (%) Maximum Pressure/
Maximum Flow Rates
Use for: Indicator Color Change H20 (g) O2 (mL) Hydrocarbons (g)
(as n-butane)
Carbon Dioxide (g) Estimated Lifetime (years)
Moisture
cat.# 22028
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
Yellow/orange to clear 7.2 >2
Oxygen
cat.# 22029
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Hydrogen
Green to grey NA 150 >2
Hydrocarbons
cat.# 22030
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
No indicator NA 12 >2
Fuel Gas1
cat.# 22022
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
Yellow/orange to clear 3.5 6 >1.5
Triple2
cat.# 22020
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Hydrogen
Yellow/orange to clear
Green to grey
1.8 75 4 >1
Helium Specific2
cat.# 21982
>99.9999 15 bar
217 psi/
7 L/min.
Helium Yellow/orange to clear
Green to grey
1.8 75 4 >1
CO2, Sulfur, Moisture
cat.# 23843
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
Yellow/orange to clear
Grey to white
3.5 6 >2

1 Removes hydrocarbons, moisture.
2 Removes hydrocarbons, moisture, oxygen.

Note:
Restek replacement filters fit all cartridge filter baseplates regardless of manufacturer. However, if the baseplate was manufactured by Agilent or Varian, the retaining nut that came with the original filter will not work and will require a universal ring nut. Please contact customer service to receive a complimentary universal ring nut.

Each baseplate unit measures: 4" x 4" x 1 7/8" (10.2 x 10.2 x 4.8 cm).

Standard baseplate inlet/outlet fittings accept 1/8" tubing. To adapt to 1/4" tubing, order 1/8" to 1/4" tube end reducers.