Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Restek Super Clean Ultra-High Capacity Oxygen Filter

Restek Super Clean ultra-high capacity oxygen filter cartridges feature easy-to-read indicators.

The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.

Documentation and Instructions Sheets

Restek Super Clean Ultra-High Capacity Oxygen Filter

Catalog # 22029

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
22029 ea. Ultra-High Capacity Oxygen Filter Select Deselect

Catalog # 22029

Units
ea.  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  
Product Name
Ultra-High Capacity Oxygen Filter  
Similar To
Agilent 5182-0818
Agilent CP17970
Scion/Bruker/Varian BRS0102

Specifications for Super Clean Gas Filters

Restek Super Clean Traps measure: 10 5/8" x 1 3/4" (27 x 4.4 cm).

          -----Capacity------  
Type of Filter Outlet Gas Quality (%) Maximum Pressure/
Maximum Flow Rates
Use for: Indicator Color Change H20 (g) O2 (mL) Hydrocarbons (g)
(as n-butane)
Carbon Dioxide (g) Estimated Lifetime (years)
Moisture
cat.# 22028
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
Yellow/orange to clear 7.2 >2
Oxygen
cat.# 22029
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Hydrogen
Green to grey NA 150 >2
Hydrocarbons
cat.# 22030
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
No indicator NA 12 >2
Fuel Gas1
cat.# 22022
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
Yellow/orange to clear 3.5 6 >1.5
Triple2
cat.# 22020
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Hydrogen
Yellow/orange to clear
Green to grey
1.8 75 4 >1
Helium Specific2
cat.# 21982
>99.9999 15 bar
217 psi/
7 L/min.
Helium Yellow/orange to clear
Green to grey
1.8 75 4 >1
CO2, Sulfur, Moisture
cat.# 23843
>99.9999 15 bar
217 psi/
7 L/min.
Inert carrier gas
Air
Hydrogen
Yellow/orange to clear
Grey to white
3.5 6 >2

1 Removes hydrocarbons, moisture.
2 Removes hydrocarbons, moisture, oxygen.

Note:
Restek replacement filters fit all cartridge filter baseplates regardless of manufacturer. However, if the baseplate was manufactured by Agilent or Varian, the retaining nut that came with the original filter will not work and will require a universal ring nut. Please contact customer service to receive a complimentary universal ring nut.