Preventive Maintenance (PM) Kits

for Waters HPLC & ACQUITY UPLC Systems

Preventive Maintenance (PM) Kits

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
25143 kit Waters 2690/2695 Pump & Autosampler PM Kit Alliance 2690, 2695 Select Deselect

Catalog # 25143

Units
kit  
Instrument
Waters  
Includes
sapphire plungers (2); seal wash plunger seals (2); head plunger seals (2); wash tube seals (4); sparge diffuser; filter insert; face seals (4); solvent reservoir 10 µm filters (4); 250 µL syringe; check valve cartridges (2); wash tube seal; seal wash tube; PTFE washer; filter retainer; lower wash seal frit; needle wash frit; TFE washer; needle assembly; gold injector seals (2); stainless steel ferrule; compression screw; seal wash face seals (2)  
Product Name
2690/2695 Pump & Autosampler PM Kit  
Model Number
Alliance 2690, 2695  
Similar To
Waters WAT270944
25144 kit Waters 600 Pump PM Kit 600 Pump Select Deselect

Catalog # 25144

Units
kit  
Instrument
Waters  
Includes
PerformancePLUS cartridges (4); sparge diffusers (4); Super Seals (2); solvent reservoir 10 µm filters (4); sapphire plungers (2); reference valve button; valve disk spacer; valve disk; TFE ball plug; TFE seat; ruby ball; inlet tube body assembly manifold insert; insert seal; belleville washers (2); flat washer  
Product Name
600 Pump PM Kit  
Model Number
600 Pump  
Similar To
Waters WAT052675
25145 kit Waters 717 Autosampler PM Kit 717 Autosampler Select Deselect

Catalog # 25145

Units
kit  
Instrument
Waters  
Includes
seal pack assembly; tube assembly (0.020" ID); needle; needle compression screw; 0.062 stainless steel ferrule; precolumn filter assembly; filter insert; 250 µL WISP syringe  
Product Name
717 Autosampler PM Kit  
Model Number
717 Autosampler  
Similar To
Waters WAT052669
25797 kit Waters ACQUITY BSM Pump Kit ACQUITY UPLC BSM Select Deselect

Catalog # 25797

Units
kit  
Instrument
Waters  
Includes
in-line filter assembly, stainless steel frit; tube assembly, transducer to check valve; tube assembly, SSV to in-line filter; primary check valve (2); wash seal, float flanged, (2); head plunger seal kit (2); sapphire plungers, (2); air filter, pump; air filter, pump handle; mixer assembly, 50 µl; accumulator check valve, double ball & seat (2); solvent bottle filter, stainless steel (7); pump O-ring, (PTFE)  
Product Name
ACQUITY BSM Pump Kit  
Model Number
ACQUITY UPLC BSM  
Similar To
Waters 201000173
25798 kit Waters ACQUITY I2V BSM Pump Kit ACQUITY UPLC I2V BSM Select Deselect

Catalog # 25798

Units
kit  
Instrument
Waters  
Includes
Tube assembly, SSV to I2v; transducer to check valve, tube assembly, I2v; wash seal, float flanged (2); head plunger seal kit (2); sapphire plungers (2); air filter, pump; air filter, pump handle; mixer assembly, 50 µL; filter frit cartridge, stainless steel; accumulator check valve, double ball & seat (2); check valve cartridge (2); solvent bottle filter, stainless steel (7); pump O-ring, (PTFE)  
Product Name
ACQUITY I2V BSM Pump Kit  
Model Number
ACQUITY UPLC I2V BSM  
Similar To
Waters 201000197
25799 kit Waters ACQUITY H-Class QSM Pump Kit ACQUITY H-CLASS QSM Select Deselect

Catalog # 25799

Units
kit  
Instrument
Waters  
Includes
solvent bottle filter, stainless steel (5); 20 micron frit holder assembly; tube assembly, transducer to check valve; wash seal, float flanged (2); head plunger seal kit (2); sapphire plungers (2); check valve, double ball & seat (2); I2 check valve cartridge; air filter, door; pump O-ring, (PTFE); mixer assembly, 100 µL  
Product Name
ACQUITY H-Class QSM Pump Kit  
Model Number
ACQUITY H-CLASS QSM  
Similar To
Waters 201000233
26430 kit Waters 1525 Pump PM Kit 1525 Pump Select Deselect

Catalog # 26430

Units
kit  
Instrument
Waters  
Includes
sapphire plungers (4); check valve cartridges (8); plunger seals (4); solvent reservoir 10 µm filters (2); reference valve button; valve disk spacer; valve disk  
Product Name
1525 Pump PM Kit  
Model Number
1525 Pump  
Similar To
Waters 201000114
26519 kit Waters 515 Pump PM Kit 515 Pump Select Deselect

Catalog # 26519

Units
kit  
Instrument
Waters  
Includes
PerformancePLUS check valves (4); sparge diffuser; solvent reservoir 10 µm filter; sapphire plungers (2); plunger seals (2); pivot inserts (2); pivot guides (2); washer (2); plunger springs (2); retaining rings (2)  
Product Name
515 Pump PM Kit  
Model Number
515 Pump  
Similar To
Waters WAT052587