Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Raptor Polar X LC Columns

  • Reliably analyze a wide variety of polar analytes (acidic, basic, and neutral) without time-consuming derivatization or complex ion pairing.
  • Switch between HILIC and ion-exchange retention modes with simple mobile phase changes and short equilibration times.
  • 2.7 μm Raptor core-shell particles provide UHPLC-like speed and efficiency on all makes and models of LC systems.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.

Storage Conditions: When not in use, Raptor Polar X columns must be kept in 100% acetonitrile. If using a buffered mobile phase, first flush thoroughly with 50:50 water:acetonitrile, then fill with acetonitrile for storage.

Technical Literature:

Ordering Notes
Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.
Documentation and Instructions Sheets

Raptor Polar X LC Columns

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9311A12 100 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9311A12

Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Polar X LC Column  
Particle Size
2.7 µm  
Pore Size
90 Å  
9311A32 30 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9311A32

Length
30 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Polar X LC Column  
Particle Size
2.7 µm  
Pore Size
90 Å  
9311A52 50 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9311A52

Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Polar X LC Column  
Particle Size
2.7 µm  
Pore Size
90 Å  
9311A5E 50 mm ea. 3.0 mm 2.7 µm Select Deselect

Catalog # 9311A5E

Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Polar X LC Column  
Particle Size
2.7 µm  
Pore Size
90 Å  

Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or "core-shell" particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times with existing HPLC and UHPLC instrumentation. Learn more about Raptor LC columns at www.restek.com/raptor

Analyzing polar compounds using liquid chromatography has historically been a challenge due to poor retention, long equilibration times, low sensitivity, and the need to mitigate these problems with time-consuming sample derivatization or complex ion-pairing approaches. However, with the development of the Raptor Polar X column—a novel column that is specifically designed for the analysis of a broad range of polar compounds—scientists can avoid these problems. These new columns feature a unique phase chemistry that combines both HILIC and ion-exchange retention mechanisms on a single ligand. Because this ligand is bound to superficially porous particles, Raptor Polar X columns both reliably retain and efficiently separate a wide variety of polar analytes with simple mobile phase changes. By analyzing polar compounds on a column that provides purpose-built resolving power, you can avoid complex sample preparation procedures, save time and money, and reduce opportunities for error. Simplify the analysis of polar compounds with the resolving power of Raptor Polar X columns from Restek.

Pore Size: 90 Å
Particle: 2.7 μm superficially porous particle (SPP) silica
Surface Area: 130 m2/g
End-Cap: Proprietary
Carbon Load: Proprietary
USP Phase Code: NA
Phase Category: Proprietary
Ligand Type: Proprietary
Recommended Usage:
pH Range: 2-8
Maximum Temperature: 60 °C
Maximum Pressure: 600 bar/8700 psi

Properties:

  • Excellent resolution and separation of a wide variety of polar compounds.
  • Combines HILIC and ion-exchange retention mechanisms together in a single ligand.
  • Broadly applicable for polar compound analysis spanning different industries and methods.

Switch to a Raptor Polar X when:

  • You are analyzing neutral, acidic, basic, or permanently charged polar compounds.
  • Performing LC-MS/MS analysis of polar compounds.
  • You are struggling to retain or elute polar compounds and considering ion chromatography.