Raptor Biphenyl LC Columns (USP L11)

  • Ideal for bioanalytical testing applications like drug and metabolite analyses.
  • Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
  • Limits ionization suppression and allows simple, MS-friendly mobile phases.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.
Ordering Notes
Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.
Documentation and Instructions Sheets

Raptor Biphenyl LC Columns (USP L11)

Catalog # 9309A52

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9309A52 50 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9309A52

Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309212 100 mm ea. 2.1 mm 1.8 µm Select Deselect

Catalog # 9309212

Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
1.8 µm  
Pore Size
90 Å  
930921E 100 mm ea. 3.0 mm 1.8 µm Select Deselect

Catalog # 930921E

Length
100 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
1.8 µm  
Pore Size
90 Å  
9309232 30 mm ea. 2.1 mm 1.8 µm Select Deselect

Catalog # 9309232

Length
30 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
1.8 µm  
Pore Size
90 Å  
9309252 50 mm ea. 2.1 mm 1.8 µm Select Deselect

Catalog # 9309252

Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
1.8 µm  
Pore Size
90 Å  
930925E 50 mm ea. 3.0 mm 1.8 µm Select Deselect

Catalog # 930925E

Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
1.8 µm  
Pore Size
90 Å  
9309262 150 mm ea. 2.1 mm 1.8 µm Select Deselect

Catalog # 9309262

Length
150 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
1.8 µm  
Pore Size
90 Å  
9309512 100 mm ea. 2.1 mm 5 µm Select Deselect

Catalog # 9309512

Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309515 100 mm ea. 4.6 mm 5 µm Select Deselect

Catalog # 9309515

Length
100 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
930951E 100 mm ea. 3.0 mm 5 µm Select Deselect

Catalog # 930951E

Length
100 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
930953E 30 mm ea. 3.0 mm 5 µm Select Deselect

Catalog # 930953E

Length
30 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309552 50 mm ea. 2.1 mm 5 µm Select Deselect

Catalog # 9309552

Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309555 50 mm ea. 4.6 mm 5 µm Select Deselect

Catalog # 9309555

Length
50 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
930955E 50 mm ea. 3.0 mm 5 µm Select Deselect

Catalog # 930955E

Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309562 150 mm ea. 2.1 mm 5 µm Select Deselect

Catalog # 9309562

Length
150 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309565 150 mm ea. 4.6 mm 5 µm Select Deselect

Catalog # 9309565

Length
150 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
930956E 150 mm ea. 3.0 mm 5 µm Select Deselect

Catalog # 930956E

Length
150 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309575 250 mm ea. 4.6 mm 5 µm Select Deselect

Catalog # 9309575

Length
250 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
5 µm  
Pore Size
90 Å  
9309A12 100 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9309A12

Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A15 100 mm ea. 4.6 mm 2.7 µm Select Deselect

Catalog # 9309A15

Length
100 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A1E 100 mm ea. 3.0 mm 2.7 µm Select Deselect

Catalog # 9309A1E

Length
100 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A32 30 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9309A32

Length
30 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A35 30 mm ea. 4.6 mm 2.7 µm Select Deselect

Catalog # 9309A35

Length
30 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A3E 30 mm ea. 3.0 mm 2.7 µm Select Deselect

Catalog # 9309A3E

Length
30 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A55 50 mm ea. 4.6 mm 2.7 µm Select Deselect

Catalog # 9309A55

Length
50 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A5E 50 mm ea. 3.0 mm 2.7 µm Select Deselect

Catalog # 9309A5E

Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A62 150 mm ea. 2.1 mm 2.7 µm Select Deselect

Catalog # 9309A62

Length
150 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A65 150 mm ea. 4.6 mm 2.7 µm Select Deselect

Catalog # 9309A65

Length
150 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  
9309A6E 150 mm ea. 3.0 mm 2.7 µm Select Deselect

Catalog # 9309A6E

Length
150 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor Biphenyl  
Particle Size
2.7 µm  
Pore Size
90 Å  

Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or "core-shell" particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times with existing HPLC and UHPLC instrumentation. Learn more about Raptor LC columns at www.restek.com/raptor

The innovative Biphenyl is Restek's most popular LC stationary phase because it is particularly adept at separating compounds that are hard to resolve or that elute early on C18 and other phenyl chemistries. As a result, the rugged Raptor Biphenyl column is extremely useful for fast separations in bioanalytical testing applications like drug and metabolite analyses, especially those that require a mass spectrometer (MS). Increasing retention of early-eluting compounds can limit ionization suppression, and the heightened selectivity helps eliminate the need for complex mobile phases that are not well suited for MS detection.

Stationary Phase Category: Phenyl (L11)
Ligand Type: Biphenyl
Particle: 1.8 µm, 2.7 µm, or 5 µm superficially porous silica (SPP or "core-shell")
Pore Size: 90 Å
Carbon Load: 7% (1.8 µm), 7% (2.7 μm), 5% (5 μm)
End-Cap: yes
Surface Area: 125 m2/g (1.8 µm), 130 m2/g (2.7 µm), or 100 m2/g (5 µm)
Recommended Usage:
pH Range: 2.0 to 8.0
Maximum Temperature: 80 °C
Maximum Pressure: 1,034 bar/15,000 psi* (1.8 μm), 600 bar/8,700 psi (2.7 μm); 400 bar/5,800 psi (5 μm)

* For maximum lifetime, recommended maximum pressure for 1.8 μm particles is 830 bar/12,000 psi.

Properties:

  • Increased retention for dipolar, unsaturated, or conjugated solutes.
  • Enhanced selectivity when used with methanolic mobile phase.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.

Switch to a Biphenyl when:

  • Limited selectivity is observed on a C18.
  • You need to increase retention of hydrophilic aromatics.
Similar Phases

Supelco/Millipore Sigma: Ascentis Express Biphenyl (2.7 µm)

Phenomenex: Kinetex Biphenyl