Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.
Share:

Raptor ARC-18 LC Columns (USP L1)

  • Ideal for high-throughput LC-MS/MS applications with minimal sample preparation.
  • Well-balanced retention profile for better detection and integration of large, multiclass analyte lists.
  • Sterically protected to endure low-pH mobile phases without sacrificing retention or peak quality.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.
Ordering Notes
Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.
Documentation and Instructions Sheets

Raptor ARC-18 LC Columns (USP L1)

Select Catalog # below
Catalog # 9314A62
Availability:
Price:
Total:
Find a Distributor

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
9314212 100 mm ea. 2.1 mm 1.8 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
1.8 µm  
Pore Size
90 Å  
931421E 100 mm ea. 3.0 mm 1.8 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
1.8 µm  
Pore Size
90 Å  
9314232 30 mm ea. 2.1 mm 1.8 µm Select Deselect
Length
30 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
1.8 µm  
Pore Size
90 Å  
9314252 50 mm ea. 2.1 mm 1.8 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
1.8 µm  
Pore Size
90 Å  
931425E 50 mm ea. 3.0 mm 1.8 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
1.8 µm  
Pore Size
90 Å  
9314262 150 mm ea. 2.1 mm 1.8 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
1.8 µm  
Pore Size
90 Å  
9314512 100 mm ea. 2.1 mm 5 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314515 100 mm ea. 4.6 mm 5 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
931451E 100 mm ea. 3.0 mm 5 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
931453E 30 mm ea. 3.0 mm 5 µm Select Deselect
Length
30 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314552 50 mm ea. 2.1 mm 5 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314555 50 mm ea. 4.6 mm 5 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
931455E 50 mm ea. 3.0 mm 5 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314562 150 mm ea. 2.1 mm 5 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314565 150 mm ea. 4.6 mm 5 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
931456E 150 mm ea. 3.0 mm 5 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314575 250 mm ea. 4.6 mm 5 µm Select Deselect
Length
250 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
5 µm  
Pore Size
90 Å  
9314A12 100 mm ea. 2.1 mm 2.7 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A15 100 mm ea. 4.6 mm 2.7 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A1E 100 mm ea. 3.0 mm 2.7 µm Select Deselect
Length
100 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A32 30 mm ea. 2.1 mm 2.7 µm Select Deselect
Length
30 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A35 30 mm ea. 4.6 mm 2.7 µm Select Deselect
Length
30 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A3E 30 mm ea. 3.0 mm 2.7 µm Select Deselect
Length
30 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A52 50 mm ea. 2.1 mm 2.7 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A55 50 mm ea. 4.6 mm 2.7 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A5E 50 mm ea. 3.0 mm 2.7 µm Select Deselect
Length
50 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A62 150 mm ea. 2.1 mm 2.7 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
2.1 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A65 150 mm ea. 4.6 mm 2.7 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
4.6 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  
9314A6E 150 mm ea. 3.0 mm 2.7 µm Select Deselect
Length
150 mm  
Units
ea.  
ID
3.0 mm  
Product Name
Raptor ARC-18  
Particle Size
2.7 µm  
Pore Size
90 Å  

Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or "core-shell" particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times with existing HPLC and UHPLC instrumentation. Learn more about Raptor LC columns at www.restek.com/raptor

Designed and intended specifically for use on LC-MS/MS systems, the Raptor ARC-18 column offers a well-balanced retention profile without the drawbacks of using an ordinary C18 in the harsh, acidic mobile phases needed for mass spectrometry (MS). Even after extended use in these low-pH (≤ 2.0) conditions, the sterically protected ARC-18 offers consistent retention, peak shape, and response for charged bases, neutral acids, small polar compounds, and more. For the rapid analysis of large, multiclass assays by LC-MS/MS, the acid-resistant Raptor ARC-18 truly is ahead of the curve.

Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: Sterically protected C18
Particle: 1.8 µm, 2.7 µm, or 5 µm superficially porous silica (SPP or "core-shell")
Pore Size: 90 Å
Carbon Load: 7% (1.8 µm), 7% (2.7 μm), 5% (5 μm)
End-Cap: no
Surface Area: 125 m2/g (1.8 µm), 130 m2/g (2.7 µm), or 100 m2/g (5 µm)
Recommended Usage:
pH Range: 1.0–8.0
Maximum Temperature: 80 °C
Maximum Pressure: 1034 bar/15000 psi* (1.8 μm), 600 bar/8700 psi (2.7 μm); 400 bar/5800 psi (5 μm)

* For maximum lifetime, recommended maximum pressure for 1.8 μm particles is 830 bar/12000 psi.

Properties:

  • Well-balanced retention profile.
  • Sterically protected and acid resistant to resist harsh, low-pH mobile phases.
  • Ideal for use with sensitive detectors like mass spec.

Switch to an ARC-18 when:

  • You are analyzing large, multiclass lists by LC-MS/MS.
  • Strongly acidic (pH 1–3) mobile phases are required.
Similar Phases

Thermo Fisher Scientific: Accucore XL C18

Supelco/Millipore Sigma: Ascentis Express Peptide ES-C18

Phenomenex: Kinetex XB-C18

Agilent: Poroshell 120 SB-C18