Rtx-Mineral Oil Columns (fused silica)

  • Application specific columns meet DIN EN ISO 9377-2:2000 requirements.
  • Optimized column dimensions for fast mineral oil screening.
  • Surface linked phase guarantees long lifetime, robustness, and stability to 400 °C.
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Rtx-Mineral Oil Columns (fused silica)

Catalog # 18074

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
18074 15 m ea. 0.32 mm Rtx-Mineral Oil 0.15 µm -60 to 380/400 °C Select Deselect

Catalog # 18074

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-Mineral Oil  
df (Film Thickness)
0.15 µm  
Temp Limits
-60 to 380/400 °C  
18075 15 m ea. 0.32 mm Rtx-Mineral Oil 0.30 µm -60 to 380/400 °C Select Deselect

Catalog # 18075

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-Mineral Oil  
df (Film Thickness)
0.30 µm  
Temp Limits
-60 to 380/400 °C  
18079 15 m ea. 0.32 mm Rtx-Mineral Oil 0.10 µm -60 to 380/400 °C Select Deselect

Catalog # 18079

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-Mineral Oil  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 380/400 °C  

The Rtx-Mineral Oil stationary phase and column dimensions were optimized for the fast screening of mineral oils in extracts from solids and water samples according to DIN EN ISO 9377-2:2000. The 0.10 µm column is the gold standard for the method, whereas the 0.15 µm column provides more complete separation of C10 from the solvent peak when large injection volumes are used. Compared with common industry solutions, the unique surface bonding of the Rtx-Mineral Oil column ensures long column lifetime, even at higher temperatures. These unique columns can be used at temperatures ranging from 380 °C (isothermal) to 400 °C (programmable), and each column is tested individually for bleed to ensure exceptional performance at these extreme conditions.