Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Rtx-1 Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane
  • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates.
  • Long lifetime and very low bleed at high operating temperatures.
  • Equivalent to USP G1, G2, G38 phases.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Rtx-1 Columns (fused silica)

Catalog # 10179

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10179 30 m ea. 0.53 mm Rtx-1 5.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10179

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/290 °C  
Similar To
Agilent 125-1035
Agilent 19095Z-623
Grace 16843
Grace 5122117
Grace 8635306
Phenomenex 7HK-G001-39
Scion/Bruker/Varian CP8775
10105 15 m ea. 0.25 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 10105

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-1011
Agilent 19091Z-331
Grace 13649
Grace 8635121
Phenomenex 7EG-G001-02
Scion/Bruker/Varian CP7700
Scion/Bruker/Varian CP7810
10106 15 m ea. 0.32 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 10106

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-1011
Grace 13673
Grace 8635147
Scion/Bruker/Varian CP7814
10107 15 m ea. 0.53 mm Rtx-1 0.10 µm -60 to 320/340 °C Select Deselect

Catalog # 10107

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 320/340 °C  
10108 30 m ea. 0.25 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 10108

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-1031
Agilent 19091Z-333
Grace 13663
Grace 8635233
Phenomenex 7HG-G001-02
Scion/Bruker/Varian CP7817
Scion/Bruker/Varian CP8710
10109 30 m ea. 0.32 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 10109

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-1031
Agilent 19091Z-313
Grace 13699
Grace 8635252
Scion/Bruker/Varian CP7855
Scion/Bruker/Varian CP8740
10110 30 m ea. 0.53 mm Rtx-1 0.10 µm -60 to 320/340 °C Select Deselect

Catalog # 10110

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 125-1039
Grace 14038
Grace 8635302
Phenomenex 7HK-G001-02
10111 60 m ea. 0.25 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 10111

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-1061
Grace 13672
Grace 8635335
Phenomenex 7KG-G001-02
Scion/Bruker/Varian CP7818
10112 60 m ea. 0.32 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 10112

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-1061
Grace 13700
Grace 8635363
Phenomenex 7KM-G001-02
Scion/Bruker/Varian CP7856
10120 15 m ea. 0.25 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10120

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-1012
Agilent 19091Z-431
Grace 13753
Grace 8635123
Phenomenex 7EG-G001-11
Scion/Bruker/Varian CP7811
Scion/Bruker/Varian CP8510

Products Often Purchased with Rtx-1 Cap. Column 15m, 0.25mm ID, 0.25um

10121 15 m ea. 0.32 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10121

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-1012
Agilent 19091Z-411
Grace 13757
Grace 8635150
Phenomenex 7EM-G001-11
Scion/Bruker/Varian CP7815
Scion/Bruker/Varian CP8530
10122 15 m ea. 0.53 mm Rtx-1 0.25 µm -60 to 320/340 °C Select Deselect

Catalog # 10122

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 125-101K
Grace 13757
Grace 8635185
10123 30 m ea. 0.25 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10123

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-1032
Agilent 19091Z-433
Grace 13638
Grace 19652
Grace 196526
Grace 5121825
Grace 5122227
Grace 5122228
Grace 8635235
Phenomenex 7HG-G001-11
Scion/Bruker/Varian CP7860
Scion/Bruker/Varian CP8741
10123-600 30 m 6-pk. 0.25 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10123-600

Length
30 m  
Units
6-pk.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Grace 196526
Grace 5122228
10124 30 m ea. 0.32 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10124

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-1032
Agilent 19091Z-413
Grace 13640
Grace 19651
Grace 5121827
Grace 5122225
Grace 8635254
Phenomenex 7HM-G001-11
Scion/Bruker/Varian CP7863
Scion/Bruker/Varian CP8742
10125 30 m ea. 0.53 mm Rtx-1 0.25 µm -60 to 320/340 °C Select Deselect

Catalog # 10125

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 125-103K
10126 60 m ea. 0.25 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10126

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-1062
Agilent 19091Z-436
Grace 13666
Grace 8635334
Phenomenex 7KG-G001-11
Scion/Bruker/Varian CP7861
Scion/Bruker/Varian CP8743

Products Often Purchased with Rtx-1 Cap. Column 60m, 0.25mm ID, 0.25um

10127 60 m ea. 0.32 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10127

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-1062
Agilent 19091Z-416
Grace 13668
Grace 8635361
Phenomenex 7KM-G001-11
Scion/Bruker/Varian CP7864
Scion/Bruker/Varian CP8744

Products Often Purchased with Rtx-1 Cap. Column 60m, 0.32mm ID, 0.25um

10128 60 m ea. 0.53 mm Rtx-1 0.25 µm -60 to 320/340 °C Select Deselect

Catalog # 10128

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320/340 °C  
10129 105 m ea. 0.25 mm Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10129

Length
105 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
10135 15 m ea. 0.25 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10135

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-101E
10136 15 m ea. 0.32 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10136

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-101E
10137 15 m ea. 0.53 mm Rtx-1 0.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10137

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-1017
Grace 14030
Grace 8635182
Phenomenex 7EK-G001-17
10138 30 m ea. 0.25 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10138

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-103E
Phenomenex 7HG-G001-17
10139 30 m ea. 0.32 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10139

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-103E
Phenomenex 7HM-G001-17
10140 30 m ea. 0.53 mm Rtx-1 0.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10140

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-1037
Phenomenex 7HK-G001-17
10141 60 m ea. 0.25 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10141

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-106E
10142 60 m ea. 0.32 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10142

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-106E
10143 60 m ea. 0.53 mm Rtx-1 0.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10143

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Grace 13898
Grace 8635389
10144 105 m ea. 0.25 mm Rtx-1 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 10144

Length
105 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091Z-530
Scion/Bruker/Varian CP7530
10150 15 m ea. 0.25 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10150

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 122-1013
Agilent 19091Z-231
Grace 13653
Grace 8635122
Phenomenex 7EG-G001-22
Scion/Bruker/Varian CP7812
Scion/Bruker/Varian CP8520
10151 15 m ea. 0.32 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10151

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 123-1013
Agilent 19091Z-211
Grace 13698
Grace 8635148
Phenomenex 7EM-G001-22
Scion/Bruker/Varian CP7758
Scion/Bruker/Varian CP8540
10152 15 m ea. 0.53 mm Rtx-1 1.00 µm -60 to 310/330 °C Select Deselect

Catalog # 10152

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-101J
Grace 13505
Grace 8635180
Scion/Bruker/Varian CP7625
10153 30 m ea. 0.25 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10153

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 122-1033
Agilent 19091Z-233
Grace 13639
Grace 5121826
Grace 8635236
Phenomenex 7HG-G001-22
Scion/Bruker/Varian CP7670
Scion/Bruker/Varian CP7862
Scion/Bruker/Varian CP8770
10154 30 m ea. 0.32 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10154

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 123-1033
Agilent 19091Z-213
Grace 13641
Grace 5121828
Grace 8635255
Phenomenex 7HM-G001-22
Scion/Bruker/Varian CP7760
Scion/Bruker/Varian CP7865
Scion/Bruker/Varian CP8760
10154-600 30 m 6-pk. 0.32 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10154-600

Length
30 m  
Units
6-pk.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
10155 30 m ea. 0.53 mm Rtx-1 1.00 µm -60 to 310/330 °C Select Deselect

Catalog # 10155

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-103J
Grace 13515
Grace 5121818
Grace 8635304

Products Often Purchased with Rtx-1 Cap. Column 30m, 0.53mm ID, 1.00um

10156 60 m ea. 0.25 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10156

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Agilent 122-1063
Agilent 19091Z-236
Grace 13667
Grace 5121846
Grace 8635336
Phenomenex 7KG-G001-22
Scion/Bruker/Varian CP7857
Scion/Bruker/Varian CP8780
10157 60 m ea. 0.32 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10157

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
Similar To
Grace 13669
Grace 8635362
Phenomenex 7KM-G001-22
Scion/Bruker/Varian CP7866
Scion/Bruker/Varian CP8870
Agilent 123-1063
Agilent 19091Z-216
10158 60 m ea. 0.53 mm Rtx-1 1.00 µm -60 to 310/330 °C Select Deselect

Catalog # 10158

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-106J
Grace 13533
Grace 8635387
10159 105 m ea. 0.25 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10159

Length
105 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
10160 105 m ea. 0.32 mm Rtx-1 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10160

Length
105 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
10166 15 m ea. 0.32 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10166

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
10167 15 m ea. 0.53 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10167

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-1012
Agilent 19095Z-321
Grace 13905
Grace 8635181
Phenomenex 7EK-G001-28
Scion/Bruker/Varian CP8674
10169 30 m ea. 0.32 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10169

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
10170 30 m ea. 0.53 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10170

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-1032
Agilent 19095Z-323
Grace 13908
Grace 5121990
Grace 8635305
Phenomenex 7HK-G001-28
Scion/Bruker/Varian CP8735
10172 60 m ea. 0.32 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10172

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 123-106B
10173 60 m ea. 0.53 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10173

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
Similar To
Agilent 125-1062
Grace 13930
Grace 8635391
Phenomenex 7KK-G001-28
Scion/Bruker/Varian CP8799
10175 105 m ea. 0.32 mm Rtx-1 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10175

Length
105 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
10176 15 m ea. 0.32 mm Rtx-1 5.00 µm -60 to 260/280 °C Select Deselect

Catalog # 10176

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 260/280 °C  
Similar To
Agilent 123-1015
Grace 16836
Grace 8635151
Scion/Bruker/Varian CP8560
10177 15 m ea. 0.53 mm Rtx-1 5.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10177

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/290 °C  
Similar To
Agilent 125-1015
Agilent 19095Z-621
Grace 16851
Grace 8635183
Phenomenex 7EK-G001-39
Scion/Bruker/Varian CP8676
10178 30 m ea. 0.32 mm Rtx-1 5.00 µm -60 to 260/280 °C Select Deselect

Catalog # 10178

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 260/280 °C  
Similar To
Agilent 123-1035
Agilent 19091Z-713
Grace 16838
Grace 5122114
Grace 8635253
Phenomenex 7HM-G001-39
Scion/Bruker/Varian CP7680
Scion/Bruker/Varian CP8688
10179-600 30 m 6-pk. 0.53 mm Rtx-1 5.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10179-600

Length
30 m  
Units
6-pk.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/290 °C  
10180 60 m ea. 0.32 mm Rtx-1 5.00 µm -60 to 260/280 °C Select Deselect

Catalog # 10180

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 260/280 °C  
Similar To
Agilent 123-1065
Agilent 19091Z-716
Grace 13704
Grace 5121876
Grace 8635365
Scion/Bruker/Varian CP8690
10180-600 60 m 6-pk. 0.32 mm Rtx-1 5.00 µm -60 to 260/280 °C Select Deselect

Catalog # 10180-600

Length
60 m  
Units
6-pk.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 260/280 °C  
10181 15 m ea. 0.32 mm Rtx-1 3.00 µm -60 to 280/300 °C Select Deselect

Catalog # 10181

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 280/300 °C  
Similar To
Agilent 123-1014
Grace 13701
Grace 8635149
Scion/Bruker/Varian CP8550
10182 15 m ea. 0.53 mm Rtx-1 3.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10182

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 270/290 °C  
Similar To
Agilent 125-1014
Agilent 19095Z-421
Grace 8635184
Phenomenex 7EK-G001-36
Scion/Bruker/Varian CP8675
Grace 13893
10183 60 m ea. 0.53 mm Rtx-1 5.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10183

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/290 °C  
Similar To
Agilent 125-1065
Agilent 19095Z-626
Grace 13810
Grace 5121944
Grace 8635392
Scion/Bruker/Varian CP8685
10184 30 m ea. 0.32 mm Rtx-1 3.00 µm -60 to 280/300 °C Select Deselect

Catalog # 10184

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 280/300 °C  
Similar To
Agilent 123-1034
Agilent 19091Z-513
Grace 13702
Grace 5121874
Grace 8635256
Scion/Bruker/Varian CP8687
10185 30 m ea. 0.53 mm Rtx-1 3.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10185

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 270/290 °C  
Similar To
Agilent 125-1034
Agilent 19095Z-423
Grace 13897
Grace 8635301
Phenomenex 7HK-G001-36
Scion/Bruker/Varian CP8677
10187 60 m ea. 0.32 mm Rtx-1 3.00 µm -60 to 280/300 °C Select Deselect

Catalog # 10187

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 280/300 °C  
Similar To
Agilent 123-1064
Grace 8635364
Phenomenex 7KM-G001-36
Scion/Bruker/Varian CP8689
Grace 13703
10188 60 m ea. 0.53 mm Rtx-1 3.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10188

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 270/290 °C  
Similar To
Agilent 125-1064
Grace 13902
Grace 8635390
10189 105 m ea. 0.53 mm Rtx-1 3.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10189

Length
105 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 270/290 °C  
10190 105 m ea. 0.32 mm Rtx-1 3.00 µm -60 to 260/280 °C Select Deselect

Catalog # 10190

Length
105 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 260/280 °C  
10191 15 m ea. 0.53 mm Rtx-1 7.00 µm -60 to 240/260 °C Select Deselect

Catalog # 10191

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
7.00 µm  
Temp Limits
-60 to 240/260 °C  
10192 30 m ea. 0.53 mm Rtx-1 7.00 µm -60 to 240/260 °C Select Deselect

Catalog # 10192

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
7.00 µm  
Temp Limits
-60 to 240/260 °C  
10193 60 m ea. 0.53 mm Rtx-1 7.00 µm -60 to 240/260 °C Select Deselect

Catalog # 10193

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
7.00 µm  
Temp Limits
-60 to 240/260 °C  
10194 105 m ea. 0.53 mm Rtx-1 5.00 µm -60 to 240/260 °C Select Deselect

Catalog # 10194

Length
105 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 240/260 °C  
10198 30 m ea. 0.32 mm Rtx-1 4.00 µm -60 to 280/300 °C Select Deselect

Catalog # 10198

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1  
df (Film Thickness)
4.00 µm  
Temp Limits
-60 to 280/300 °C  
Similar To
Agilent 19091Z-613
40101 10 m ea. 0.18 mm Rtx-1 0.20 µm -60 to 330/350 °C Select Deselect

Catalog # 40101

Length
10 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.20 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 121-101A
Grace 13819
Grace 5121945
40102 20 m ea. 0.18 mm Rtx-1 0.20 µm -60 to 330/350 °C Select Deselect

Catalog # 40102

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.20 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 121-102A
40103 40 m ea. 0.18 mm Rtx-1 0.20 µm -60 to 330/350 °C Select Deselect

Catalog # 40103

Length
40 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.20 µm  
Temp Limits
-60 to 330/350 °C  
40110 10 m ea. 0.18 mm Rtx-1 0.40 µm -60 to 330/340 °C Select Deselect

Catalog # 40110

Length
10 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
Temp Limits
-60 to 330/340 °C  
Similar To
Agilent 121-1013
40111 20 m ea. 0.18 mm Rtx-1 0.40 µm -60 to 330/340 °C Select Deselect

Catalog # 40111

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
Temp Limits
-60 to 330/340 °C  
Similar To
Agilent 121-1023
40112 40 m ea. 0.18 mm Rtx-1 0.40 µm -60 to 330/340 °C Select Deselect

Catalog # 40112

Length
40 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
Temp Limits
-60 to 330/340 °C  
Similar To
Agilent 121-1043
41101 10 m ea. 0.10 mm Rtx-1 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 41101

Length
10 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 127-1012
41102 20 m ea. 0.10 mm Rtx-1 0.10 µm -60 to 330/360 °C Select Deselect

Catalog # 41102

Length
20 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/360 °C  
Similar To
Agilent 127-1022
41103 10 m ea. 0.10 mm Rtx-1 0.40 µm -60 to 330/340 °C Select Deselect

Catalog # 41103

Length
10 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
Temp Limits
-60 to 330/340 °C  
Similar To
Agilent 127-1013
41104 20 m ea. 0.10 mm Rtx-1 0.40 µm -60 to 330/350 °C Select Deselect

Catalog # 41104

Length
20 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 127-1023

Similar Phases

Phenomenex: ZB-1

Agilent: CP-Sil 5 CB, DB-1, HP-1