Rtx-1701 Columns (fused silica)

midpolarity Crossbond phase
  • General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), and fragrance compounds.
  • Equivalent to USP G46 phase.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Rtx-1701 Columns (fused silica)

Catalog # 12023

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
12023 30 m ea. 0.25 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12023

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 122-0732
Grace 13686
Grace 5121859
Phenomenex 7HG-G006-11
Scion/Bruker/Varian CP8712
12009 30 m ea. 0.32 mm Rtx-1701 0.10 µm -20 to 280 °C Select Deselect

Catalog # 12009

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.10 µm  
Temp Limits
-20 to 280 °C  
12011 60 m ea. 0.25 mm Rtx-1701 0.10 µm -20 to 280 °C Select Deselect

Catalog # 12011

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.10 µm  
Temp Limits
-20 to 280 °C  
12020 15 m ea. 0.25 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12020

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 122-0712
Grace 13881
Grace 8635125
Phenomenex 7EG-G006-11
Scion/Bruker/Varian CP8512
12021 15 m ea. 0.32 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12021

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 123-0712
Phenomenex 7EM-G006-11
Scion/Bruker/Varian CP8542
12023-600 30 m 6-pk. 0.25 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12023-600

Length
30 m  
Units
6-pk.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
12024 30 m ea. 0.32 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12024

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 123-0732
Grace 13690
Grace 5121863
Phenomenex 7HM-G006-11
Scion/Bruker/Varian CP8842
12025 30 m ea. 0.53 mm Rtx-1701 0.25 µm -20 to 270/280 °C Select Deselect

Catalog # 12025

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 270/280 °C  
Similar To
Agilent 125-0731
12026 60 m ea. 0.25 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12026

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 122-0762
Phenomenex 7KG-G006-11
Scion/Bruker/Varian CP8722
12027 60 m ea. 0.32 mm Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12027

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 123-0762
Phenomenex 7KM-G006-11
Scion/Bruker/Varian CP8852
12035 15 m ea. 0.25 mm Rtx-1701 0.50 µm -20 to 270/280 °C Select Deselect

Catalog # 12035

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 270/280 °C  
12036 15 m ea. 0.32 mm Rtx-1701 0.50 µm -20 to 270/280 °C Select Deselect

Catalog # 12036

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 270/280 °C  
12037 15 m ea. 0.53 mm Rtx-1701 0.50 µm -20 to 260/270 °C Select Deselect

Catalog # 12037

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 260/270 °C  
Similar To
Agilent 125-0717
Grace 14046
Grace 8635178
Scion/Bruker/Varian CP8663
12038 30 m ea. 0.25 mm Rtx-1701 0.50 µm -20 to 270/280 °C Select Deselect

Catalog # 12038

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 270/280 °C  
12039 30 m ea. 0.32 mm Rtx-1701 0.50 µm -20 to 270/280 °C Select Deselect

Catalog # 12039

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 270/280 °C  
12040 30 m ea. 0.53 mm Rtx-1701 0.50 µm -20 to 260/270 °C Select Deselect

Catalog # 12040

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 260/270 °C  
Similar To
Agilent 125-0737
12041 60 m ea. 0.25 mm Rtx-1701 0.50 µm -20 to 270/280 °C Select Deselect

Catalog # 12041

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 270/280 °C  
Similar To
Agilent 122-0766
12042 60 m ea. 0.32 mm Rtx-1701 0.50 µm -20 to 270/280 °C Select Deselect

Catalog # 12042

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
Temp Limits
-20 to 270/280 °C  
12050 15 m ea. 0.25 mm Rtx-1701 1.00 µm -20 to 260/280 °C Select Deselect

Catalog # 12050

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 260/280 °C  
Similar To
Agilent 122-0713
Grace 13718
Grace 8635120
12051 15 m ea. 0.32 mm Rtx-1701 1.00 µm -20 to 260/280 °C Select Deselect

Catalog # 12051

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 260/280 °C  
Similar To
Agilent 123-0713
Phenomenex 7EM-G006-22
Scion/Bruker/Varian CP8552
12052 15 m ea. 0.53 mm Rtx-1701 1.00 µm -20 to 250/270 °C Select Deselect

Catalog # 12052

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 250/270 °C  
Similar To
Agilent 125-0712
12053 30 m ea. 0.25 mm Rtx-1701 1.00 µm -20 to 260/280 °C Select Deselect

Catalog # 12053

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 260/280 °C  
Similar To
Agilent 122-0733
Phenomenex 7HG-G006-22
Scion/Bruker/Varian CP8562
12054 30 m ea. 0.32 mm Rtx-1701 1.00 µm -20 to 260/280 °C Select Deselect

Catalog # 12054

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 260/280 °C  
Similar To
Agilent 123-0733
Grace 13691
Grace 5121864
Phenomenex 7HM-G006-22
Scion/Bruker/Varian CP8762
12055 30 m ea. 0.53 mm Rtx-1701 1.00 µm -20 to 250/270 °C Select Deselect

Catalog # 12055

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 250/270 °C  
Similar To
Agilent 125-0732
Phenomenex 7HK-G006-22
Scion/Bruker/Varian CP8737
12056 60 m ea. 0.25 mm Rtx-1701 1.00 µm -20 to 260/280 °C Select Deselect

Catalog # 12056

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 260/280 °C  
Similar To
Agilent 122-0763
Scion/Bruker/Varian CP8572
12057 60 m ea. 0.32 mm Rtx-1701 1.00 µm -20 to 260/280 °C Select Deselect

Catalog # 12057

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 260/280 °C  
Similar To
Agilent 123-0763
Scion/Bruker/Varian CP8772
12058 60 m ea. 0.53 mm Rtx-1701 1.00 µm -20 to 240/270 °C Select Deselect

Catalog # 12058

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
Temp Limits
-20 to 240/270 °C  
12066 15 m ea. 0.32 mm Rtx-1701 1.50 µm -20 to 240/260 °C Select Deselect

Catalog # 12066

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.50 µm  
Temp Limits
-20 to 240/260 °C  
12069 30 m ea. 0.32 mm Rtx-1701 1.50 µm -20 to 240/260 °C Select Deselect

Catalog # 12069

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.50 µm  
Temp Limits
-20 to 240/260 °C  
12070 30 m ea. 0.53 mm Rtx-1701 1.50 µm -20 to 240/260 °C Select Deselect

Catalog # 12070

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.50 µm  
Temp Limits
-20 to 240/260 °C  
Similar To
Agilent 125-0733
12072 60 m ea. 0.32 mm Rtx-1701 1.50 µm -20 to 240/260 °C Select Deselect

Catalog # 12072

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.50 µm  
Temp Limits
-20 to 240/260 °C  
12073 60 m ea. 0.53 mm Rtx-1701 1.50 µm -20 to 240/260 °C Select Deselect

Catalog # 12073

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
1.50 µm  
Temp Limits
-20 to 240/260 °C  
Similar To
Agilent 125-0763
12082 15 m ea. 0.53 mm Rtx-1701 3.00 µm -20 to 230/250 °C Select Deselect

Catalog # 12082

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
3.00 µm  
Temp Limits
-20 to 230/250 °C  
12085 30 m ea. 0.53 mm Rtx-1701 3.00 µm -20 to 230/250 °C Select Deselect

Catalog # 12085

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
3.00 µm  
Temp Limits
-20 to 230/250 °C  
12088 60 m ea. 0.53 mm Rtx-1701 3.00 µm -20 to 220/250 °C Select Deselect

Catalog # 12088

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-1701  
df (Film Thickness)
3.00 µm  
Temp Limits
-20 to 220/250 °C  
42001 10 m ea. 0.18 mm Rtx-1701 0.20 µm -20 to 280 °C Select Deselect

Catalog # 42001

Length
10 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.20 µm  
Temp Limits
-20 to 280 °C  
42002 20 m ea. 0.18 mm Rtx-1701 0.20 µm -20 to 280 °C Select Deselect

Catalog # 42002

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.20 µm  
Temp Limits
-20 to 280 °C  
42003 40 m ea. 0.18 mm Rtx-1701 0.20 µm -20 to 280 °C Select Deselect

Catalog # 42003

Length
40 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.20 µm  
Temp Limits
-20 to 280 °C  
42011 20 m ea. 0.18 mm Rtx-1701 0.40 µm -20 to 280 °C Select Deselect

Catalog # 42011

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.40 µm  
Temp Limits
-20 to 280 °C  
Similar To
Agilent 121-0723
42012 40 m ea. 0.18 mm Rtx-1701 0.40 µm -20 to 280 °C Select Deselect

Catalog # 42012

Length
40 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.40 µm  
Temp Limits
-20 to 280 °C  
42201 10 m ea. 0.10 mm Rtx-1701 0.10 µm -20 to 280 °C Select Deselect

Catalog # 42201

Length
10 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.10 µm  
Temp Limits
-20 to 280 °C  
42202 20 m ea. 0.10 mm Rtx-1701 0.10 µm -20 to 270/280 °C Select Deselect

Catalog # 42202

Length
20 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rtx-1701  
df (Film Thickness)
0.10 µm  
Temp Limits
-20 to 270/280 °C  
Similar To
Agilent 127-0722

Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for confirmation analysis in combination with an Rtx-35 or Rtx-5 column. The polymer is fully characterized to ensure long-term reproducibility, column-to-column consistency, and low bleed, even with sensitive detectors such as ECDs and MSDs.
Similar Phases

Agilent: VF-1701 Pesticides, VF-1701ms, CP-Sil 19 CB, DB-1701, DB-1701P

Phenomenex: ZB-1701, ZB-1701P