Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Stabilwax Columns (fused silica)

polar phase; Crossbond polyethylene glycol
  • Low-bleed PEG column ensures long column lifetimes.
  • Temperature range: 40 °C to 260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Stabilwax Columns (fused silica)

Catalog # 10655

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10655 30 m ea. 0.53 mm Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10655

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 125-7332
Grace 13907
Grace 5121989
10605 15 m ea. 0.25 mm Stabilwax 0.10 µm 40 to 250/260 °C Select Deselect

Catalog # 10605

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
10608 30 m ea. 0.25 mm Stabilwax 0.10 µm 40 to 250/260 °C Select Deselect

Catalog # 10608

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
10611 60 m ea. 0.25 mm Stabilwax 0.10 µm 40 to 250/260 °C Select Deselect

Catalog # 10611

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
10620 15 m ea. 0.25 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10620

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-7312
Agilent 19091N-131
Grace 13777
Grace 8635118
Scion/Bruker/Varian CP8513
10621 15 m ea. 0.32 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10621

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Grace 13779
Grace 8635165
Scion/Bruker/Varian CP8543
Agilent 123-7312
Agilent 19091N-111
10622 15 m ea. 0.53 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10622

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
10623 30 m ea. 0.25 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10623

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-7332
Agilent 19091N-133
Grace 12437
Grace 19655
Grace 136462
Grace 5121748
Grace 5121833
Grace 5122232
Grace 8635044
Grace 8635230
Scion/Bruker/Varian CP8713
10623-600 30 m 6-pk. 0.25 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10623-600

Length
30 m  
Units
6-pk.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Grace 196556
Grace 5122233
10624 30 m ea. 0.32 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10624

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-7332
Agilent 19091N-113
Grace 12439
Grace 19654
Grace 136482
Grace 5121750
Grace 5121835
Grace 5122230
Grace 8635053
Grace 8635275
Scion/Bruker/Varian CP8843
10625 30 m ea. 0.53 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10625

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
10626 60 m ea. 0.25 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10626

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-7362
Agilent 19091N-136
Grace 12447
Grace 12605
Grace 136942
Grace 5121751
Grace 5121768
Grace 5121867
Grace 8635350
Grace 8635356
Scion/Bruker/Varian CP8723
10627 60 m ea. 0.32 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10627

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-7362
Agilent 19091N-116
Grace 12449
Grace 136962
Grace 5121752
Grace 8635372
Scion/Bruker/Varian CP8853
10628 60 m ea. 0.53 mm Stabilwax 0.25 µm 40 to 250/260 °C Select Deselect

Catalog # 10628

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
10635 15 m ea. 0.25 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10635

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-7313
Agilent 19091N-231
Grace 137302
Grace 8635116
Scion/Bruker/Varian CP8523
10636 15 m ea. 0.32 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10636

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-7313
Agilent 19091N-211
Grace 137352
Grace 8635162
Scion/Bruker/Varian CP8553
10637 15 m ea. 0.53 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10637

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Grace 14109
Grace 8635174
10638 30 m ea. 0.25 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10638

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-7333
Agilent 19091N-233
Grace 136472
Grace 5121834
Scion/Bruker/Varian CP8746
10639 30 m ea. 0.32 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10639

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-7333
Agilent 19091N-213
Grace 136522
Grace 5121837
Scion/Bruker/Varian CP8763
10640 30 m ea. 0.53 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10640

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Grace 14111
Grace 5122051
10641 60 m ea. 0.25 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10641

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-7363
Agilent 19091N-236
Grace 13916
Grace 8635348
Scion/Bruker/Varian CP8748
10642 60 m ea. 0.32 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10642

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-7363
Agilent 19091N-216
Grace 13901
Grace 136972
Grace 5121869
Grace 8635382
Scion/Bruker/Varian CP8773
10643 60 m ea. 0.53 mm Stabilwax 0.50 µm 40 to 250/260 °C Select Deselect

Catalog # 10643

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
10651 15 m ea. 0.32 mm Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10651

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 123-7314
Grace 137312
Grace 8635117
10652 15 m ea. 0.53 mm Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10652

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 125-7312
Grace 13904
Grace 137362
Grace 5121986
Grace 8635163
10654 30 m ea. 0.32 mm Stabilwax 1.00 µm 40 to 240/260 °C Select Deselect

Catalog # 10654

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/260 °C  
Similar To
Agilent 123-7334
Grace 137382
Grace 5121900

Products Often Purchased with Stabilwax Cap. Column 30m, 0.32mm ID, 1.00um

10655-600 30 m 6-pk. 0.53 mm Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10655-600

Length
30 m  
Units
6-pk.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
10657 60 m ea. 0.32 mm Stabilwax 1.00 µm 40 to 240/260 °C Select Deselect

Catalog # 10657

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/260 °C  
Similar To
Agilent 123-7364
10658 60 m ea. 0.53 mm Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10658

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 125-7362
Grace 13929
Grace 5121995
10666 15 m ea. 0.53 mm Stabilwax 1.50 µm 40 to 230/240 °C Select Deselect

Catalog # 10666

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.50 µm  
Temp Limits
40 to 230/240 °C  
Similar To
Grace 13215
Grace 8635173
10667 15 m ea. 0.53 mm Stabilwax 2.00 µm 40 to 220/230 °C Select Deselect

Catalog # 10667

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
2.00 µm  
Temp Limits
40 to 220/230 °C  
Similar To
Agilent 125-7314
10669 30 m ea. 0.53 mm Stabilwax 1.50 µm 40 to 230/240 °C Select Deselect

Catalog # 10669

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.50 µm  
Temp Limits
40 to 230/240 °C  
Similar To
Agilent 125-7333
Grace 13109
Grace 8635286
10670 30 m ea. 0.53 mm Stabilwax 2.00 µm 40 to 220/230 °C Select Deselect

Catalog # 10670

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
2.00 µm  
Temp Limits
40 to 220/230 °C  
Similar To
Agilent 125-7334
10672 60 m ea. 0.53 mm Stabilwax 1.50 µm 40 to 230/240 °C Select Deselect

Catalog # 10672

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax  
df (Film Thickness)
1.50 µm  
Temp Limits
40 to 230/240 °C  
Similar To
Agilent 125-7363
Grace 13243
Grace 8635380
40602 20 m ea. 0.18 mm Stabilwax 0.18 µm 40 to 250 °C Select Deselect

Catalog # 40602

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.18 µm  
Temp Limits
40 to 250 °C  
42601 10 m ea. 0.10 mm Stabilwax 0.10 µm 40 to 250/260 °C Select Deselect

Catalog # 42601

Length
10 m  
Units
ea.  
ID
0.10 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
43830 10 m ea. 0.15 mm Stabilwax 0.15 µm 40 to 250/260 °C Select Deselect

Catalog # 43830

Length
10 m  
Units
ea.  
ID
0.15 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.15 µm  
Temp Limits
40 to 250/260 °C  
43831 20 m ea. 0.15 mm Stabilwax 0.15 µm 40 to 250/260 °C Select Deselect

Catalog # 43831

Length
20 m  
Units
ea.  
ID
0.15 mm  
Product Name
Stabilwax  
df (Film Thickness)
0.15 µm  
Temp Limits
40 to 250/260 °C  

Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column lifetimes, even when programming repeatedly up to 260 °C. The bonding mechanism of the column also produces polar compound retention times that do not shift, as is often observed on other wax-type columns. In addition, this bonding mechanism produces a column that can be rejuvenated by solvent washing. Stabilwax columns are used for a wide range of compounds and matrices including FAMEs, flavor compounds, essential oils, solvents, aromatics (including xylene isomers), acrolein/acrylonitrile (EPA 603), and oxygenated compounds. Also used for purity testing of chemicals and analyzing alcoholic beverages.
Similar Phases

Agilent: VF-WAX MS, CP-Wax 52 CB, HP-INNOWax

Phenomenex: ZB-WAXplus