Stabilwax-DA Columns (fused silica)

polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds
  • Application-specific columns for free (underivatized) acids, some inorganic acids.
  • Resistant to oxidative damage.
  • Equivalent to USP G25, G35 phases.
  • Ideal for analyzing distilled liquor and other alcoholic beverages.
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Stabilwax-DA Columns (fused silica)

Select Catalog # below
Catalog # 11005
Availability:
Price:
Total:
Find a Distributor

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
11005 15 m ea. 0.25 mm Stabilwax-DA 0.10 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
11007 15 m ea. 0.53 mm Stabilwax-DA 0.10 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
11008 30 m ea. 0.25 mm Stabilwax-DA 0.10 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
11009 30 m ea. 0.32 mm Stabilwax-DA 0.10 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.10 µm  
Temp Limits
40 to 250/260 °C  
11020 15 m ea. 0.25 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-3212
Agilent 19091F-431
Grace 13782
Grace 8635135
Phenomenex 7EG-G009-11
11021 15 m ea. 0.32 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-3212
Agilent 19091F-411
Grace 13886
Grace 8635170
Phenomenex 7EM-G009-11
11022 15 m ea. 0.53 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
11023 30 m ea. 0.25 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-3232
Agilent 19019F-433
Grace 13783
Grace 14537
Grace 5121925
Grace 5122065
Grace 8635247
Phenomenex 7HG-G009-11
Scion/Bruker/Varian CP7717
11024 30 m ea. 0.32 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-3232
Agilent 19091F-413
Grace 13785
Grace 14539
Grace 5122066
Grace 8635266
Phenomenex 7HM-G009-11
11025 30 m ea. 0.53 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 125-3231
11026 60 m ea. 0.25 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-3262
Grace 13784
Grace 14547
Grace 5122068
Grace 8635345
Phenomenex 7KG-G009-11
Scion/Bruker/Varian CP7727
11027 60 m ea. 0.32 mm Stabilwax-DA 0.25 µm 40 to 250/260 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-3262
Grace 13786
Grace 8635359
11035 15 m ea. 0.25 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
11036 15 m ea. 0.32 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
11037 15 m ea. 0.53 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 125-3217
11038 30 m ea. 0.25 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-3233
11039 30 m ea. 0.32 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-3233
Phenomenex 7HM-G009-17
11040 30 m ea. 0.53 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 125-3237
11041 60 m ea. 0.25 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 122-3263
11042 60 m ea. 0.32 mm Stabilwax-DA 0.50 µm 40 to 250/260 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
0.50 µm  
Temp Limits
40 to 250/260 °C  
Similar To
Agilent 123-3263
11051 15 m ea. 0.32 mm Stabilwax-DA 1.00 µm 40 to 240/250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 123-3214
11052 15 m ea. 0.53 mm Stabilwax-DA 1.00 µm 40 to 240/250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 125-3212
Agilent 19095F-120
Grace 13873
Grace 5121962
Grace 8635191
Phenomenex 7EK-G009-22
11054 30 m ea. 0.32 mm Stabilwax-DA 1.00 µm 40 to 240/250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 123-3234
Scion/Bruker/Varian CP7767
11055 30 m ea. 0.53 mm Stabilwax-DA 1.00 µm 40 to 240/250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 125-3232
Agilent 19095F-123
Grace 14543
Grace 5121965
Grace 5122067
Grace 8635284
Phenomenex 7HK-G009-22
Scion/Bruker/Varian CP7486
Scion/Bruker/Varian CP7614
Grace 13877
11057 60 m ea. 0.32 mm Stabilwax-DA 1.00 µm 40 to 240/250 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 123-3264
Grace 13276
Grace 8635358
Scion/Bruker/Varian CP7777
11058 60 m ea. 0.53 mm Stabilwax-DA 1.00 µm 40 to 240/250 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  
Similar To
Agilent 125-3262
Grace 13879
Grace 5121967
Grace 8635402
Scion/Bruker/Varian CP7624
11062 15 m ea. 0.53 mm Stabilwax-DA 1.50 µm 40 to 230/240 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.50 µm  
Temp Limits
40 to 230/240 °C  
11065 30 m ea. 0.53 mm Stabilwax-DA 1.50 µm 40 to 230/240 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.50 µm  
Temp Limits
40 to 230/240 °C  
Similar To
Agilent 125-3233
Scion/Bruker/Varian CP7654
11068 60 m ea. 0.53 mm Stabilwax-DA 1.50 µm 40 to 230/240 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Stabilwax-DA  
df (Film Thickness)
1.50 µm  
Temp Limits
40 to 230/240 °C  

Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces adsorption of acids, and increases sample capacity for volatile free acids. Stabilwax-DA columns last longer and give better peak shapes for high molecular weight acids.

Some inorganic acids also chromatograph well on a Stabilwax-DA column; the limitation is the volatility of the acidic compound.

Stabilwax-DA columns should not be rinsed with water.
Similar Phases

Phenomenex: ZB-FFAP

Agilent: CP-WAX 58 FFAP CB, DB-FFAP, HP-FFAP

Supelco/Millipore Sigma: NUKOL