Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Innovative Integra-Guard Columns

Get the protection without the connection!

  • These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems!
  • The guard column section is marked separately from the analytical column, using high-temperature string.
  • A wide variety of our Integra-Guard capillary columns are available.
  • Analyzing residual solvents in pharmaceutical products? Use cat.# 16085-126 or 10279-126 below.
Documentation and Instructions Sheets

Innovative Integra-Guard Columns

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10120-124 15 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10120-124

Length
15 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-1 Cap. Column 15m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

10123-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10123-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-1 Cap. Column 30m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

10126-127 60 m ea. 0.25 mm w/10 m Integra-Guard Column Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10126-127

Length
60 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-1 Cap. Column 60m, 0.25mm ID, 0.25um with 10m Integra-Guard Column

10127-125 60 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-1 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10127-125

Length
60 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-1 Cap. Column 60m, 0.32mm ID, 0.25um w/ 5m, 0.32mm ID Integra-Guard

10155-126 30 m ea. 0.53 mm w/5 m Integra-Guard Column Rtx-1 1.00 µm -60 to 310/330 °C Select Deselect

Catalog # 10155-126

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 310/330 °C  

Products Often Purchased with Rtx-1 Cap. Column 30m, 0.53mm ID, 1.00um with 5m Integra-Guard Column

10179-126 30 m ea. 0.53 mm w/5 m Integra-Guard Column Rtx-1 5.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10179-126

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/290 °C  

Products Often Purchased with Rtx-1 Cap. Column 30m, 0.53mm ID, 5.00um with 5m Integra-Guard Column

10220-124 15 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10220-124

Length
15 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5 Cap. Column 15m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

10223-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10223-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5 Cap. Column 30m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

10223-127 30 m ea. 0.25 mm w/10 m Integra-Guard Column Rtx-5 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10223-127

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5 Cap. Column 30m, 0.25mm ID, 0.25um with 10m Integra-Guard Column

10224-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-5 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10224-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5 Cap. Column 30m, 0.32mm ID, 0.25um with 5m Integra-Guard Column

10227-125 60 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-5 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 10227-125

Length
60 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5 Cap. Column 60m, 0.32mm ID, 0.25um with 5m Integra-Guard Column

10240-129 30 m ea. 0.53 mm w/10 m Integra-Guard Column Rtx-5 0.50 µm -60 to 310/330 °C Select Deselect

Catalog # 10240-129

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 310/330 °C  

Products Often Purchased with Rtx-5 Cap. Column 30m, 0.53mm ID, 0.50um with 10m Integra-Guard Column

10253-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 10253-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  

Products Often Purchased with Rtx-5 Cap. Column 30m, 0.25mm ID, 1.00um with 5m Integra-Guard Column

10254-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-5 1.00 µm -60 to 330/350 °C Select Deselect

Catalog # 10254-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5 Cap. Column 30m, 0.32mm ID, 1.00um with 5m Integra-Guard Column

10279-126 30 m ea. 0.53 mm w/5 m Integra-Guard Column Rtx-5/Rtx-G27 5.00 µm -60 to 270/290 °C Select Deselect

Catalog # 10279-126

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/5 m Integra-Guard Column  
Note
Application-specific column for residual solvents in pharmaceutical products.  
Product Name
Rtx-5/Rtx-G27  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/290 °C  

Products Often Purchased with Rtx-5/Rtx-G27 Cap. Column 30m, 0.53mm ID, 5.00um with 5m Integra-Guard Column

10623-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Stabilwax 0.25 µm 40 to 250 °C Select Deselect

Catalog # 10623-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
Temp Limits
40 to 250 °C  

Products Often Purchased with Stabilwax Cap. Column 30m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

10654-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10654-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  

Products Often Purchased with Stabilwax Cap. Column 30m, 0.32mm ID, 1.00um with 5m Integra-Guard Column

10655-126 30 m ea. 0.53 mm w/5 m Integra-Guard Column Stabilwax 1.00 µm 40 to 240/250 °C Select Deselect

Catalog # 10655-126

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/250 °C  

Products Often Purchased with Stabilwax Cap. Column 30m, 0.53mm ID, 1.00um with 5m Integra-Guard Column

10655-129 30 m ea. 0.53 mm w/10 m Integra-Guard Column Stabilwax 1.00 µm 40 to 240/260 °C Select Deselect

Catalog # 10655-129

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
Temp Limits
40 to 240/260 °C  

Products Often Purchased with Stabilwax Cap. Column 30m, 0.53mm ID, 1.00um with 10m Integra-Guard Column

10968-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-624 1.40 µm -20 to 240 °C Select Deselect

Catalog # 10968-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-624  
df (Film Thickness)
1.40 µm  
Temp Limits
-20 to 240 °C  
10970-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-624 1.80 µm -20 to 240 °C Select Deselect

Catalog # 10970-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-624  
df (Film Thickness)
1.80 µm  
Temp Limits
-20 to 240 °C  

Products Often Purchased with Rtx-624 Cap. Column 30m, 0.32mm ID, 1.80um with 5m Integra-Guard Column

10971-126 30 m ea. 0.53 mm w/5 m Integra-Guard Column Rtx-624 3.00 µm -20 to 240 °C Select Deselect

Catalog # 10971-126

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-624  
df (Film Thickness)
3.00 µm  
Temp Limits
-20 to 240 °C  

Products Often Purchased with Rtx-624 Cap. Column 30m, 0.53mm ID, 3.00um with 5m Integra-Guard Column

12023-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-1701 0.25 µm -20 to 280 °C Select Deselect

Catalog # 12023-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
Temp Limits
-20 to 280 °C  

Products Often Purchased with Rtx-1701 Cap. Column 30m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

12608-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5MS 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 12608-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.25mm ID, 0.10um with 5m Integra-Guard Column

12620-124 15 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12620-124

Length
15 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 15m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

12620-124600 15 m 6-pk. 0.25 mm w/5 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12620-124600

Length
15 m  
Units
6-pk.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 15m, 0.25mm ID, 0.25um with 5m Integra-Guard Column, 6-pk.

12623-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12623-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

12623-127 30 m ea. 0.25 mm w/10 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12623-127

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.25mm ID, 0.25um with 10m Integra-Guard Column

12624-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12624-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.32mm ID, 0.25um with 5m Integra-Guard Column

12626-124 60 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12626-124

Length
60 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 60m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

12626-127 60 m ea. 0.25 mm w/10 m Integra-Guard Column Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12626-127

Length
60 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 60m, 0.25mm ID, 0.25um with 10m Integra-Guard Column

12635-127 15 m ea. 0.25 mm w/10 m Integra-Guard Column Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12635-127

Length
15 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 15m, 0.25mm ID, 0.50um with 10m Integra-Guard Column

12638-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12638-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.25mm ID, 0.50um with 5m Integra-Guard Column

12638-127 30 m ea. 0.25 mm w/10 m Integra-Guard Column Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12638-127

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.25mm ID, 0.50um with 10m Integra-Guard Column

12654-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rtx-5MS 1.00 µm -60 to 325/350 °C Select Deselect

Catalog # 12654-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 325/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.32mm ID, 1.00um with 5m Integra-Guard Column

13620-127 15 m ea. 0.25 mm w/10 m Integra-Guard Column Rxi-5Sil MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 13620-127

Length
15 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rxi-5Sil MS Cap. Column 15m, 0.25mm ID, 0.25um with 10m Integra-Guard Column

13623-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rxi-5Sil MS 0.25 µm -60 to 320/350 °C Select Deselect

Catalog # 13623-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320/350 °C  
Similar To
Agilent 122-5631G5
Phenomenex 7HG-G010-11-GGA

Products Often Purchased with Rxi-5Sil MS Cap. Column 30m, 0.25mm ID, 0.25um with 5m Integra-Guard Column

13623-127 30 m ea. 0.25 mm w/10 m Integra-Guard Column Rxi-5Sil MS 0.25 µm -60 to 320/350 °C Select Deselect

Catalog # 13623-127

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320/350 °C  
Similar To
Agilent 122-5532G
Phenomenex 7HG-G010-11-GGC

Products Often Purchased with Rxi-5Sil MS Cap. Column 30m, 0.25mm ID, 0.25um with 10m Integra-Guard Column

13635-124 15 m ea. 0.25 mm w/5 m Integra-Guard Column Rxi-5Sil MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 13635-124

Length
15 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rxi-5Sil MS Cap. Column 15m, 0.25mm ID, 0.50um with 5m ID Integra-Guard Column

13638-124 30 m ea. 0.25 mm w/5 m Integra-Guard Column Rxi-5Sil MS 0.50 µm -60 to 320/350 °C Select Deselect

Catalog # 13638-124

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 320/350 °C  

Products Often Purchased with Rxi-5Sil MS Cap. Column 30m, 0.25mm ID, 0.50um with 5m Integra-Guard Column

13638-127 30 m ea. 0.25 mm w/10 m Integra-Guard Column Rxi-5Sil MS 0.50 µm -60 to 320/350 °C Select Deselect

Catalog # 13638-127

Length
30 m  
Units
ea.  
ID
0.25 mm  
Modification
w/10 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 320/350 °C  
Similar To
Agilent 122-5536G

Products Often Purchased with Rxi-5Sil MS Cap. Column 30m, 0.25mm ID, 0.50um with 10m Integra-Guard Column

13639-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rxi-5Sil MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 13639-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rxi-5Sil MS Cap. Column 30m, 0.32mm ID, 0.50um with 5m Integra-Guard Column

13654-125 30 m ea. 0.32 mm w/5 m Integra-Guard Column Rxi-5Sil MS 1.00 µm -60 to 325/350 °C Select Deselect

Catalog # 13654-125

Length
30 m  
Units
ea.  
ID
0.32 mm  
Modification
w/5 m Integra-Guard Column  
Product Name
Rxi-5Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 325/350 °C  

Products Often Purchased with Rxi-5Sil MS Cap. Column 30m, 0.32mm ID, 1.00um with 5m Integra-Guard Column

16085-126 30 m ea. 0.53 mm w/5 m Integra-Guard Column Rtx-1301/Rtx-G43 3.00 µm -20 to 240 °C Select Deselect

Catalog # 16085-126

Length
30 m  
Units
ea.  
ID
0.53 mm  
Modification
w/5 m Integra-Guard Column  
Note
Application-specific column for residual solvents in pharmaceutical products. Meets all requirements of USP <467>.  
Product Name
Rtx-1301/Rtx-G43  
df (Film Thickness)
3.00 µm  
Temp Limits
-20 to 240 °C  

Products Often Purchased with Rtx-1301 Cap. Column 30m, 0.53mm ID, 3.00um with 5m Integra-Guard Column (Rtx-G43)

  • No leaks for a more robust method.
  • No column connections for easier, faster maintenance.
  • No peak distortions due to connector dead volume and thermal capacity.

For analysts who find it inconvenient to make a leak-free connection between the guard column and the analytical column, we offer Integra-Guard columns. These innovative columns incorporate both a guard column and an analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! The guard column section is marked separately from the analytical column using high-temperature string.

A wide variety of our Integra-Guard capillary columns are listed here. The Integra-Guard column is so economical that we challenge you to compare our price against that of a conventional connection, even if you assemble it yourself. If you are currently using a guard column, or are considering using one, call today and ask about Integra-Guard columns.

Integra-Guard columns are available for all phases listed for columns with 0.25, 0.32, or 0.53 mm ID. If you don’t see what you need here, contact Customer Service.

Rtx-1
Rtx-5
Rtx-5MS
Rxi-5Sil MS
Rtx-624
Rtx-1301
Rtx-1701
Stabilwax

Similar Phases

Alltech/MEGA S.r.l.: DuraGuard

Agilent: EZ-Guard

Phenomenex: Guardian