PLEASE NOTE: Due to a planned systems upgrade, purchase orders submitted after 10:00 a.m. ET, Friday, April 23, will not be processed until 8:00 a.m. ET, Monday, April 26. We apologize for the inconvenience.
Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.
Share:

Rxi-1ms Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane
  • General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G1, G2, and G38 phases.
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Rxi-1ms Columns (fused silica)

Select Catalog # below
Catalog # 13301
Availability:
Price:
Total:
Find a Distributor

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
13301 10 m ea. 0.10 mm Rxi-1ms 0.10 µm -60 to 330/350 °C Select Deselect
Length
10 m  
Units
ea.  
ID
0.10 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 127-0112
Phenomenex 7CB-G011-02
13302 20 m ea. 0.18 mm Rxi-1ms 0.18 µm -60 to 330/350 °C Select Deselect
Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.18 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 121-0122
Agilent 19091s-677
Phenomenex 7FD-G011-08
13311 20 m ea. 0.18 mm Rxi-1ms 0.36 µm -60 to 330/350 °C Select Deselect
Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.36 µm  
Temp Limits
-60 to 330/350 °C  
13320 15 m ea. 0.25 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-0112
Agilent 19091s-931
Grace 15880
Grace 8635141
Phenomenex 7EG-G011-11
13320-600 15 m 6-pk. 0.25 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
6-pk.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
13321 15 m ea. 0.32 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-0112
Agilent 19091s-911
Grace 15882
Grace 8635154
Phenomenex 7EM-G011-11
13323 30 m ea. 0.25 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-0132
Agilent 19091s-933
Grace 15897
Grace 5122102
Grace 8635244
Phenomenex 7HG-G011-11
13324 30 m ea. 0.32 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-0132
Agilent 19091s-913
Grace 15938
Grace 8635273
Phenomenex 7HM-G011-11
13326 60 m ea. 0.25 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 122-0162
Agilent 19091s-936
Grace 15941
Grace 8635354
Phenomenex 7KG-G011-11
13327 60 m ea. 0.32 mm Rxi-1ms 0.25 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 123-0162
Agilent 19091s-916
Grace 15944
Grace 8635377
13335 15 m ea. 0.25 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13336 15 m ea. 0.32 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13337 15 m ea. 0.53 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13338 30 m ea. 0.25 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091s-633
Phenomenex 7HG-G011-17
13339 30 m ea. 0.32 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13340 30 m ea. 0.53 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13341 60 m ea. 0.25 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13342 60 m ea. 0.32 mm Rxi-1ms 0.50 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
13350 15 m ea. 0.25 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
13352 15 m ea. 0.53 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
13353 30 m ea. 0.25 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091s-733
Phenomenex 7HG-G011-22
13354 30 m ea. 0.32 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091s-713
Phenomenex 7HM-G011-22
13355 30 m ea. 0.53 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
13356 60 m ea. 0.25 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Phenomenex 7KG-G011-22
13357 60 m ea. 0.32 mm Rxi-1ms 1.00 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Phenomenex 7KM-G011-22
13367 15 m ea. 0.53 mm Rxi-1ms 1.50 µm -60 to 330/350 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 330/350 °C  
13370 30 m ea. 0.53 mm Rxi-1ms 1.50 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 330/350 °C  
13373 60 m ea. 0.53 mm Rxi-1ms 1.50 µm -60 to 330/350 °C Select Deselect
Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 330/350 °C  
13396 30 m ea. 0.32 mm Rxi-1ms 4.00 µm -60 to 330/350 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
4.00 µm  
Temp Limits
-60 to 330/350 °C  
13397 12 m ea. 0.20 mm Rxi-1ms 0.33 µm -60 to 330/350 °C Select Deselect
Length
12 m  
Units
ea.  
ID
0.20 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 128-0112
Phenomenex 7DE-G011-14
13397-600 12 m 6-pk. 0.20 mm Rxi-1ms 0.33 µm -60 to 330/350 °C Select Deselect
Length
12 m  
Units
6-pk.  
ID
0.20 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
Temp Limits
-60 to 330/350 °C  
13398 25 m ea. 0.20 mm Rxi-1ms 0.33 µm -60 to 330/350 °C Select Deselect
Length
25 m  
Units
ea.  
ID
0.20 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 128-0122
Agilent 19091s-602
Phenomenex 7GE-G011-14
13399 50 m ea. 0.20 mm Rxi-1ms 0.33 µm -60 to 330/350 °C Select Deselect
Length
50 m  
Units
ea.  
ID
0.20 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
Temp Limits
-60 to 330/350 °C  
43800 10 m ea. 0.15 mm Rxi-1ms 0.15 µm -60 to 330/350 °C Select Deselect
Length
10 m  
Units
ea.  
ID
0.15 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.15 µm  
Temp Limits
-60 to 330/350 °C  
43801 20 m ea. 0.15 mm Rxi-1ms 0.15 µm -60 to 330/350 °C Select Deselect
Length
20 m  
Units
ea.  
ID
0.15 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
0.15 µm  
Temp Limits
-60 to 330/350 °C  
43802 20 m ea. 0.15 mm Rxi-1ms 2.0 µm -60 to 330/350 °C Select Deselect
Length
20 m  
Units
ea.  
ID
0.15 mm  
Product Name
Rxi-1ms  
df (Film Thickness)
2.0 µm  
Temp Limits
-60 to 330/350 °C  

What do Rxi columns mean to you? Three things:

  • Ultra-low bleed.
  • Exceptional inertness.
  • Reproducible performance, column after column.

Rxi fused silica capillary GC columns were designed specifically to be the best columns available for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column characteristics assures Rxi columns will have long lifetimes. Restek chemists have also developed a stable, reproducible manufacturing process so that Rxi columns will meet your needs every time you install a new column.

Similar Phases

Agilent: Ultra-1, VF-1ms, DB-1ms, DB-1msUI, HP-1ms, HP-1msUI

Phenomenex: ZB-1ms