Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Rtx-5MS—Low-Bleed GC-MS Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane
  • General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Column specifically tested for low-bleed performance.
  • Temperature range: -60 °C to 350 °C.
  • Equivalent to USP G27 and G36 phases.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

Rtx-5MS—Low-Bleed GC-MS Columns (fused silica)

Catalog # 12608

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
12608 30 m ea. 0.25 mm Rtx-5MS 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 12608

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-333
Scion/Bruker/Varian CP5870

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.25mm ID, 0.10um

12605 15 m ea. 0.25 mm Rtx-5MS 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 12605

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-331
Scion/Bruker/Varian CP5867
12606 15 m ea. 0.32 mm Rtx-5MS 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 12606

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-311
Scion/Bruker/Varian CP5873
12609 30 m ea. 0.32 mm Rtx-5MS 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 12609

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-313
Scion/Bruker/Varian CP5877
12611 60 m ea. 0.25 mm Rtx-5MS 0.10 µm -60 to 330/350 °C Select Deselect

Catalog # 12611

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-336
Scion/Bruker/Varian CP5872
12620 15 m ea. 0.25 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12620

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-431
Scion/Bruker/Varian CP5868
12620-600 15 m 6-pk. 0.25 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12620-600

Length
15 m  
Units
6-pk.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
12621 15 m ea. 0.32 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12621

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-411
12623 30 m ea. 0.25 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12623

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-433
Scion/Bruker/Varian CP5860
12623-600 30 m 6-pk. 0.25 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12623-600

Length
30 m  
Units
6-pk.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
12624 30 m ea. 0.32 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12624

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-413
Scion/Bruker/Varian CP5863

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.32mm ID, 0.25um

12626 60 m ea. 0.25 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12626

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-436
Scion/Bruker/Varian CP5861
12627 60 m ea. 0.32 mm Rtx-5MS 0.25 µm -60 to 330/350 °C Select Deselect

Catalog # 12627

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-416
Scion/Bruker/Varian CP5864
12635 15 m ea. 0.25 mm Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12635

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  

Products Often Purchased with Rtx-5MS Cap. Column 15m, 0.25mm ID, 0.50um

12637 15 m ea. 0.53 mm Rtx-5MS 0.50 µm -60 to 320/340 °C Select Deselect

Catalog # 12637

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 320/340 °C  
12638 30 m ea. 0.25 mm Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12638

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-133
Scion/Bruker/Varian CP5871
12639 30 m ea. 0.32 mm Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12639

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
Similar To
Agilent 19091S-113
Scion/Bruker/Varian CP5880
12640 30 m ea. 0.53 mm Rtx-5MS 0.50 µm -60 to 320/340 °C Select Deselect

Catalog # 12640

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 320/340 °C  
12641 60 m ea. 0.25 mm Rtx-5MS 0.50 µm -60 to 320/350 °C Select Deselect

Catalog # 12641

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 320/350 °C  
12642 60 m ea. 0.32 mm Rtx-5MS 0.50 µm -60 to 330/350 °C Select Deselect

Catalog # 12642

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/350 °C  
12650 15 m ea. 0.25 mm Rtx-5MS 1.00 µm -60 to 325/350 °C Select Deselect

Catalog # 12650

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 325/350 °C  
Similar To
Agilent 19091S-231
Scion/Bruker/Varian CP5869
12652 15 m ea. 0.53 mm Rtx-5MS 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 12652

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
12653 30 m ea. 0.25 mm Rtx-5MS 1.00 µm -60 to 325/350 °C Select Deselect

Catalog # 12653

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 325/350 °C  
Similar To
Agilent 19091S-233
Scion/Bruker/Varian CP5862
12654 30 m ea. 0.32 mm Rtx-5MS 1.00 µm -60 to 325/350 °C Select Deselect

Catalog # 12654

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 325/350 °C  
Similar To
Agilent 19091S-213
Scion/Bruker/Varian CP5865

Products Often Purchased with Rtx-5MS Cap. Column 30m, 0.32mm ID, 1.00um

12655 30 m ea. 0.53 mm Rtx-5MS 1.00 µm -60 to 320/340 °C Select Deselect

Catalog # 12655

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/340 °C  
12667 15 m ea. 0.53 mm Rtx-5MS 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 12667

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  
12670 30 m ea. 0.53 mm Rtx-5MS 1.50 µm -60 to 310/330 °C Select Deselect

Catalog # 12670

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rtx-5MS  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/330 °C  

Rtx-5MS columns are coated with a 5% diphenyl/95% dimethyl polysiloxane phase and are tested to rigorous specifications for low bleed and high inertness. They have polarity identical to Rtx-5 columns, but exhibit lower bleed.

Rxi-5Sil MS columns are coated with a silarylene phase that exhibits polarity very similar to a 5% diphenyl/95% dimethyl polysiloxane phase, but the phenyl rings in the polymer chain of the silarylene phase impart improved thermal stability and lower bleed. The Rxi-5Sil MS column is an ideal choice for analyzing EPA Method 8270 semivolatile pollutants. The slight difference in the selectivity of Rxi-5Sil MS columns also improves separation of polycyclic aromatic hydrocarbons (PAH), such as benzo[b]- and benzo[k]- fluoranthene isomers.

Note: The DB-5MS is a silarylene-based polymer equivalent to the Rxi-5Sil MS.
Similar Phases

Supelco/Millipore Sigma: SPB-5