MXT-1 Columns (Siltek-treated stainless steel)

nonpolar phase; Crossbond dimethyl polysiloxane
  • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, and oxygenates.
  • Equivalent to USP G1, G2, G38 phases.
  • 4.5" standard coil diameter.
  • Performing high-temperature simulated distillation (SimDist) analysis? Use cat.# 70101 below.
Ordering Notes
Custom lengths and film thicknesses available. Call Technical Service at 800-356-1688 or 814-353-1300, ext. 4, or contact your Restek representative.

SAVE MONEY! Get six columns for the price of five. Call 800-356-1688, ext. 3, or your Restek representative for details!
Documentation and Instructions Sheets

MXT-1 Columns (Siltek-treated stainless steel)

Catalog # 70179

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
70179 30 m ea. 0.53 mm 5.00 µm -60 to 270/360 °C Select Deselect

Catalog # 70179

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/360 °C  
Similar To
Agilent 145-1035
70101 6 m ea. 0.53 mm 0.15 µm -60 to 400/430 °C Select Deselect

Catalog # 70101

Length
6 m  
Units
ea.  
ID
0.53 mm  
Note
Meets temperature and resolution criteria for high-temperature simulated distillation (SimDist), including ASTM Method D2887 Extended and D6352. Methyl silicone polymer gives the correct retention time/boiling point curve.  
Product Name
MXT-1 SimDist  
df (Film Thickness)
0.15 µm  
Temp Limits
-60 to 400/430 °C  
Similar To
Agilent 145-1001
Agilent 19095Z-220
70102 6 m ea. 0.28 mm 0.10 µm -60 to 400/430 °C Select Deselect

Catalog # 70102

Length
6 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 400/430 °C  
70105 15 m ea. 0.25 mm 0.10 µm -60 to 360/430 °C Select Deselect

Catalog # 70105

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 360/430 °C  
70106 15 m ea. 0.28 mm 0.10 µm -60 to 360/430 °C Select Deselect

Catalog # 70106

Length
15 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 360/430 °C  
70107 15 m ea. 0.53 mm 0.15 µm -60 to 360/430 °C Select Deselect

Catalog # 70107

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.15 µm  
Temp Limits
-60 to 360/430 °C  
70109 30 m ea. 0.28 mm 0.10 µm -60 to 360/430 °C Select Deselect

Catalog # 70109

Length
30 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 360/430 °C  
70116 30 m ea. 0.25 mm 0.10 µm -60 to 330/430 °C Select Deselect

Catalog # 70116

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.10 µm  
Temp Limits
-60 to 330/430 °C  
70120 15 m ea. 0.25 mm 0.25 µm -60 to 360/430 °C Select Deselect

Catalog # 70120

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 360/430 °C  
70121 15 m ea. 0.28 mm 0.25 µm -60 to 360/430 °C Select Deselect

Catalog # 70121

Length
15 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 360/430 °C  
70122 15 m ea. 0.53 mm 0.25 µm -60 to 360/430 °C Select Deselect

Catalog # 70122

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 360/430 °C  
70123 30 m ea. 0.25 mm 0.25 µm -60 to 330/430 °C Select Deselect

Catalog # 70123

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 330/430 °C  
70124 30 m ea. 0.28 mm 0.25 µm -60 to 360/430 °C Select Deselect

Catalog # 70124

Length
30 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 360/430 °C  
70125 30 m ea. 0.53 mm 0.25 µm -60 to 360/430 °C Select Deselect

Catalog # 70125

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 360/430 °C  
70126 60 m ea. 0.25 mm 0.25 µm -60 to 340/430 °C Select Deselect

Catalog # 70126

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 340/430 °C  
70128 60 m ea. 0.53 mm 0.25 µm -60 to 340/430 °C Select Deselect

Catalog # 70128

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 340/430 °C  
70129 105 m ea. 0.25 mm 0.25 µm -60 to 340/430 °C Select Deselect

Catalog # 70129

Length
105 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 340/430 °C  
70135 15 m ea. 0.25 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70135

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
70137 15 m ea. 0.53 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70137

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
Similar To
Agilent 145-1017
Scion/Bruker/Varian CP7125
70138 30 m ea. 0.25 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70138

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
70139 30 m ea. 0.28 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70139

Length
30 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
70139-273 30 m ea. 0.28 mm 3.5" Coil 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70139-273

Length
30 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
Column Configuration
3.5" Coil  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
70140 30 m ea. 0.53 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70140

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
Similar To
Agilent 145-1037
Scion/Bruker/Varian CP7135
70142 60 m ea. 0.28 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70142

Length
60 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
70143 60 m ea. 0.53 mm 0.50 µm -60 to 330/400 °C Select Deselect

Catalog # 70143

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
0.50 µm  
Temp Limits
-60 to 330/400 °C  
70150 15 m ea. 0.25 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70150

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70151 15 m ea. 0.28 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70151

Length
15 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70152 15 m ea. 0.53 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70152

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70153 30 m ea. 0.25 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70153

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70154 30 m ea. 0.28 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70154

Length
30 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70154-600 30 m 6-pk. 0.28 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70154-600

Length
30 m  
Units
6-pk.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70155 30 m ea. 0.53 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70155

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70155-271 30 m ea. 0.53 mm 6" Coil 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70155-271

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
Column Configuration
6" Coil  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70156 60 m ea. 0.25 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70156

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70157 60 m ea. 0.28 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70157

Length
60 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70158 60 m ea. 0.53 mm 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70158

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70158-271 60 m ea. 0.53 mm 6" Coil 1.00 µm -60 to 320/360 °C Select Deselect

Catalog # 70158-271

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
Column Configuration
6" Coil  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320/360 °C  
70159 105 m ea. 0.25 mm 1.00 µm -60 to 310/360 °C Select Deselect

Catalog # 70159

Length
105 m  
Units
ea.  
ID
0.25 mm  
Product Name
MXT-1  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 310/360 °C  
70167 15 m ea. 0.53 mm 1.50 µm -60 to 310/360 °C Select Deselect

Catalog # 70167

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/360 °C  
Similar To
Agilent 145-1012
70170 30 m ea. 0.53 mm 1.50 µm -60 to 310/360 °C Select Deselect

Catalog # 70170

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/360 °C  
Similar To
Agilent 145-1032
70173 60 m ea. 0.53 mm 1.50 µm -60 to 310/360 °C Select Deselect

Catalog # 70173

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 310/360 °C  
70177 15 m ea. 0.53 mm 5.00 µm -60 to 270/360 °C Select Deselect

Catalog # 70177

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/360 °C  
70177-273 15 m ea. 0.53 mm 3.5" Coil 5.00 µm -60 to 270/360 °C Select Deselect

Catalog # 70177-273

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
Column Configuration
3.5" Coil  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/360 °C  
70179-273 30 m ea. 0.53 mm 3.5" Coil 5.00 µm -60 to 270/360 °C Select Deselect

Catalog # 70179-273

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
Column Configuration
3.5" Coil  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/360 °C  
70181 15 m ea. 0.28 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70181

Length
15 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
70182 15 m ea. 0.53 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70182

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
70183 60 m ea. 0.53 mm 5.00 µm -60 to 270/360 °C Select Deselect

Catalog # 70183

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/360 °C  
70183-273 60 m ea. 0.53 mm 3.5" Coil 5.00 µm -60 to 270/360 °C Select Deselect

Catalog # 70183-273

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
Column Configuration
3.5" Coil  
df (Film Thickness)
5.00 µm  
Temp Limits
-60 to 270/360 °C  
70184 30 m ea. 0.28 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70184

Length
30 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
70185 30 m ea. 0.53 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70185

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
Similar To
Agilent 145-1034
70187 60 m ea. 0.28 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70187

Length
60 m  
Units
ea.  
ID
0.28 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
70188 60 m ea. 0.53 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70188

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
70189 105 m ea. 0.53 mm 3.00 µm -60 to 285/360 °C Select Deselect

Catalog # 70189

Length
105 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 285/360 °C  
70191 15 m ea. 0.53 mm 7.00 µm -60 to 240/360 °C Select Deselect

Catalog # 70191

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
7.00 µm  
Temp Limits
-60 to 240/360 °C  
70192 30 m ea. 0.53 mm 7.00 µm -60 to 250/360 °C Select Deselect

Catalog # 70192

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
7.00 µm  
Temp Limits
-60 to 250/360 °C  
70193 60 m ea. 0.53 mm 7.00 µm -60 to 250/360 °C Select Deselect

Catalog # 70193

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
MXT-1  
df (Film Thickness)
7.00 µm  
Temp Limits
-60 to 250/360 °C  
71811 10 m ea. 0.18 mm 0.20 µm -60 to 330/430 °C Select Deselect

Catalog # 71811

Length
10 m  
Units
ea.  
ID
0.18 mm  
Product Name
MXT-1  
df (Film Thickness)
0.20 µm  
Temp Limits
-60 to 330/430 °C  
71812 20 m ea. 0.18 mm 0.20 µm -60 to 330/430 °C Select Deselect

Catalog # 71812

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
MXT-1  
df (Film Thickness)
0.20 µm  
Temp Limits
-60 to 330/430 °C  
71815 20 m ea. 0.18 mm 0.40 µm -60 to 320/400 °C Select Deselect

Catalog # 71815

Length
20 m  
Units
ea.  
ID
0.18 mm  
Product Name
MXT-1  
df (Film Thickness)
0.40 µm  
Temp Limits
-60 to 320/400 °C  

MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed.
Similar Phases

Quadrex: UAC-1, UAC-1MS

Agilent: DB-PS1