D3606 Application Column Set (packed, 2 column set)

  • Accurate quantification of toluene and benzene—including benzene in gasoline containing ethanol or butanol blends.
  • Complete resolution of benzene from ethanol—no compromising coelutions.
  • Enhanced formulation with improved support material and polymers—more robust and reproducible.
  • Column sets are individually tested for D3606 method applicability.
  • QC test chromatogram includes approximate backflush times.
  • Listed in the ASTM Method D3606—attain better separation of benzene and ethanol while following ASTM method requirements.
  • Includes: Column 1: Backflush column, 6' (1.8 m), 1/8" OD, 2.0 mm ID; Column 2: proprietary packing, 15.5' (4.7 m), 1/8" OD, 2.0 mm ID
Ordering Notes
See Description below for column configuration key.

Custom packed and micropacked columns also available by request.
Documentation and Instructions Sheets

D3606 Application Column Set (packed, 2 column set)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
83606A-800 2 column set D3606 Application Column (2 column set) General up to 140 °C Select Deselect

Catalog # 83606A-800

Units
2 column set  
Product Name
D3606 Application Column (2 column set)  
Column Configuration
General  
Temp Limits
up to 140 °C  
Similar To
Restek 83606-800
83606A-810 2 column set D3606 Application Column (2 column set) Agilent up to 140 °C Select Deselect

Catalog # 83606A-810

Units
2 column set  
Product Name
D3606 Application Column (2 column set)  
Column Configuration
Agilent  
Temp Limits
up to 140 °C  
Similar To
Restek 83606-810
83606A-811 2 column set D3606 Application Column (2 column set) Agilent 6850 up to 140 °C Select Deselect

Catalog # 83606A-811

Units
2 column set  
Product Name
D3606 Application Column (2 column set)  
Column Configuration
Agilent 6850  
Temp Limits
up to 140 °C  
83606A-821 2 column set D3606 Application Column (2 column set) Bruker 430, 450, Varian 3800 up to 140 °C Select Deselect

Catalog # 83606A-821

Units
2 column set  
Product Name
D3606 Application Column (2 column set)  
Column Configuration
Bruker 430, 450, Varian 3800  
Temp Limits
up to 140 °C  
83606A-840 2 column set D3606 Application Column (2 column set) PE Auto Sys up to 140 °C Select Deselect

Catalog # 83606A-840

Units
2 column set  
Product Name
D3606 Application Column (2 column set)  
Column Configuration
PE Auto Sys  
Temp Limits
up to 140 °C  
Similar To
Restek 83606-840
83606A-850 2 column set D3606 Application Column (2 column set) Shimadzu 14A up to 140 °C Select Deselect

Catalog # 83606A-850

Units
2 column set  
Product Name
D3606 Application Column (2 column set)  
Column Configuration
Shimadzu 14A  
Temp Limits
up to 140 °C  
Similar To
Restek 83606-850

Conforms to the specifications established in the current ASTM method D3606 for the quantitation of benzene and toluene in spark ignition fuel containing ethanol.

The inlet is identified on both column 1 and column 2. Note: The inlet of column 2 is identified for proper orientation for connection to the valve.

Column Configuration Key:
-800 General—General Configuration
-810 Agilent—(HP) 5880, 5890, 5987, 6890, 7980
-811 Agilent 6850
-821 Bruker 430, 450, Varian 3800
-840 PE Auto Sys—PE Auto System 8300/8400/8700, Clarus 500
-850 Shimadzu 14A—Shimadzu 14A, 2014

Other column configurations available.