Rt-QS-BOND Columns (fused silica PLOT)

porous divinylbenzene homopolymer
  • Intermediate polarity porous polymer PLOT column incorporating low 4-vinylpyridine.
  • Separates ethane, ethylene, and acetylene to baseline.
  • Temperature range: -60 to 250 °C.
A GC column phase cross-reference is also available.
Documentation and Instructions Sheets

Rt-QS-BOND Columns (fused silica PLOT)

Select Catalog # below
Catalog # 19737
Availability:
Price:
Total:
Find a Distributor

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
19737 15 m ea. 0.53 mm 20 µm -60 to 250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rt-QS-BOND  
df (Film Thickness)
20 µm  
Temp Limits
-60 to 250 °C  
19738 30 m ea. 0.53 mm 20 µm -60 to 250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rt-QS-BOND  
df (Film Thickness)
20 µm  
Temp Limits
-60 to 250 °C  
19739 15 m ea. 0.32 mm 10 µm -60 to 250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rt-QS-BOND  
df (Film Thickness)
10 µm  
Temp Limits
-60 to 250 °C  
19740 30 m ea. 0.32 mm 10 µm -60 to 250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rt-QS-BOND  
df (Film Thickness)
10 µm  
Temp Limits
-60 to 250 °C  
19767 15 m ea. 0.25 mm 8 µm -60 to 250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rt-QS-BOND  
df (Film Thickness)
8 µm  
Temp Limits
-60 to 250 °C  
19768 30 m ea. 0.25 mm 8 µm -60 to 250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rt-QS-BOND  
df (Film Thickness)
8 µm  
Temp Limits
-60 to 250 °C  

Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The Q-BOND is our most nonpolar and widely used porous polymer column; functional groups can be added to increase polarity (i.e., QS-, S-, and U-BOND). The process used to manufacture porous polymer PLOT columns causes the particles to adhere strongly to the walls of the tubing, so there is virtually no particle generation. You get reproducible performance from column to column, including selectivity and flow.

We do not recommend recoiling PLOT columns as this may cause particles to dislodge from the side of the tubing.