PLEASE NOTE: Due to a planned systems upgrade, purchase orders submitted after 10:00 a.m. ET, Friday, April 23, will not be processed until 8:00 a.m. ET, Monday, April 26. We apologize for the inconvenience.
Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.
Share:

Rt-S-BOND Columns (fused silica PLOT)

porous divinylbenzene homopolymer
  • Midpolarity porous polymer PLOT column, incorporating high 4-vinylpyridine.
  • Use for the analysis of nonpolar and polar compounds.
  • Temperature range: -60 to 250 °C.
A GC column phase cross-reference is also available.
Documentation and Instructions Sheets

Rt-S-BOND Columns (fused silica PLOT)

Select Catalog # below
Catalog # 19745
Availability:
Price:
Total:
Find a Distributor

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
19745 15 m ea. 0.53 mm 20 µm -60 to 250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rt-S-BOND  
df (Film Thickness)
20 µm  
Temp Limits
-60 to 250 °C  
19746 30 m ea. 0.53 mm 20 µm -60 to 250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rt-S-BOND  
df (Film Thickness)
20 µm  
Temp Limits
-60 to 250 °C  
19748 30 m ea. 0.32 mm 10 µm -60 to 250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rt-S-BOND  
df (Film Thickness)
10 µm  
Temp Limits
-60 to 250 °C  
19769 15 m ea. 0.25 mm 8 µm -60 to 250 °C Select Deselect
Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rt-S-BOND  
df (Film Thickness)
8 µm  
Temp Limits
-60 to 250 °C  
19770 30 m ea. 0.25 mm 8 µm -60 to 250 °C Select Deselect
Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rt-S-BOND  
df (Film Thickness)
8 µm  
Temp Limits
-60 to 250 °C  

Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The Q-BOND is our most nonpolar and widely used porous polymer column; functional groups can be added to increase polarity (i.e., QS-, S-, and U-BOND). The process used to manufacture porous polymer PLOT columns causes the particles to adhere strongly to the walls of the tubing, so there is virtually no particle generation. You get reproducible performance from column to column, including selectivity and flow.

We do not recommend recoiling PLOT columns as this may cause particles to dislodge from the side of the tubing.
Similar Phases

Agilent: CP-PoraPLOT S