This kit contains one ampul of each of the following:
Arizona Pesticide Standard #1 (cat.# 32601)
Arizona Pesticide Standard #2 (cat.# 32602)
Arizona Pesticide Standard #3 (cat.# 32603)
Arizona Pesticide Standard #4 (cat.# 32604)
Contains 1 ampul of each of the following. 1 mL/ampul
Cat.# 32601: Arizona Pesticide Standard #1
Acephate (30560-19-1), 160 µg/mL
Aldicarb (116-06-3), 160 µg/mL
Bifenazate (149877-41-8), 80 µg/mL
Carbaryl (sevin) (63-25-2), 80 µg/mL
Carbofuran (1563-66-2), 80 µg/mL
Chlorpyrifos (2921-88-2), 80 µg/mL
Dichlorvos (62-73-7), 40 µg/mL
Diazinon (333-41-5), 80 µg/mL
Dimethoate (60-51-5), 80 µg/mL
Ethoprophos (13194-48-4), 80 µg/mL
Fenoxycarb (72490-01-8), 80 µg/mL
Malathion (121-75-5), 80 µg/mL
Methiocarb (2032-65-7), 80 µg/mL
Methomyl (16752-77-5), 160 µg/mL
Naled (300-76-5), 200 µg/mL
Oxamyl (23135-22-0), 400 µg/mL
Phosmet (732-11-6), 80 µg/mL
Propoxur (114-26-1), 80 µg/mL
Cat.# 32602: Arizona Pesticide Standard #2
Abamectin (71751-41-2), 200 µg/mL
Acequinocyl (57960-19-7), 800 µg/mL
Bifenthrin (82657-04-3), 80 µg/mL
Cyfluthrin (68359-37-5), 400 µg/mL
Cypermethrin (52315-07-8), 400 µg/mL
Etofenprox (80844-07-1), 160 µg/mL
Permethrin (cis & trans) (52645-53-1), 80 µg/mL
Prallethrin (23031-36-9), 80 µg/mL
Pyrethrins (8003-34-7), 400 µg/mL
Spinosad (A&D) (168316-95-8)*, 120 µg/mL
Cat.# 32603: Arizona Pesticide Standard #3
Acetamiprid (135410-20-7), 80 µg/mL
Clofentezine (74115-24-5), 80 µg/mL
Etoxazole (153233-91-1), 80 µg/mL
Fipronil (120068-37-3), 160 µg/mL
Fludioxonil (131341-86-1), 160 µg/mL
Imazalil (35554-44-0), 80 µg/mL
Imidacloprid (138261-41-3), 160 µg/mL
Myclobutanil (88671-89-0), 80 µg/mL
Paclobutrazol (76738-62-0), 160 µg/mL
Pendimethalin (40487-42-1), 40 µg/mL
Propiconazole (Tilt) (60207-90-1), 160 µg/mL
Tebuconazole (107534-96-3), 160 µg/mL
Thiacloprid (111988-49-9), 80 µg/mL
Thiamethoxam (153719-23-4), 80 µg/mL
Cat.# 32604: Arizona Pesticide Standard #4
Azoxystrobin (131860-33-8), 80 µg/mL
Boscalid (188425-85-6), 160 µg/mL
Chlorantraniliprole (500008-45-7), 80 µg/mL
Chlorfenapyr (122453-73-0), 400 µg/mL
Daminozide (1596-84-5), 400 µg/mL
(E)-Fenpyroximate (134098-61-6), 160 µg/mL
Flonicamid (158062-67-0), 400 µg/mL
Hexythiazox (78587-05-0), 400 µg/mL
Kresoxim methyl (143390-89-0), 160 µg/mL
Metalaxyl (57837-19-1), 80 µg/mL
Piperonyl butoxide (51-03-6), 800 µg/mL
Pyridaben (96489-71-3), 80 µg/mL
Spiromesifen (283594-90-1), 80 µg/mL
Spirotetramat (203313-25-1), 80 µg/mL
Spiroxamine (118134-30-8), 160 µg/mL
Trifloxystrobin (141517-21-7), 80 µg/mL
*This reference material contains Spinosad A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of Spinosad A and D and the ratio of each material isomer are displayed your certificate of analysis.