Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

DHA Paraffins Standard (11 components)

This standard is produced for refineries performing Detailed Hydrocarbon Analysis (DHA) of crude oil feedstocks and fuels. It helps with calibrating complex hydrocarbon analyses and provides the greatest number of gravimetrically determined values for qualitative calibration to help our customers optimize production and maximize profitability—while fulfilling requirements such as ASTM Methods D6729, D6730, and D6733.

DHA Paraffins Standard (11 components)

Catalog # 30725

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
30725 ea. Neat, 0.15 mL in Autosampler Vial DHA Paraffins Standard Select Deselect

Catalog # 30725

Units
ea.  
Conc. in Solvent and Volume
Neat, 0.15 mL in Autosampler Vial  
Product Name
DHA Paraffins Standard  
Certified Reference Material (CRM)
No  
Shipping Conditions
Ambient  
Storage Temperature
10 °C or colder  

    Compound, Conc (wt/wt%)
    N-Decane, 9.134%
    N-Dodecane, 9.089%
    N-Heptane, 9.066%
    N-Hexane, 9.097%
    N-Nonane, 9.086%
    N-Octane, 9.054%
    N-Pentadecane, 9.123%
    N-Pentane, 9.094%
    N-Tetradecane, 9.128%
    N-Tridecane, 9.064%
    N-Undecane, 9.064%

ASTM Methods D6729, D6730, and D6733 (Determination of Individual Components in Spark Ignition Engine Fuels) are designed for the determination of the individual hydrocarbons present in spark ignition engine fuels, as well as fuel blends containing oxygenates such as methyl tert-butyl ether, ethyl tert-butyl ether, tert-butanol, ethanol, etc.