DHA PONA Standard (188 components)

This standard is a qualitative mixture of various gasoline and refinery materials prepared to provide nearly every component that may be encountered in feedstock and finished gasolines. Some oxygenates have been added to allow this blend to be used by refineries for Detailed Hydrocarbon Analysis (DHA) method setup and to fulfill requirements such as ASTM Methods D6729, D6730, and D6733.

DHA PONA Standard (188 components)

Catalog # 30731

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
30731 ea. Neat, 0.15 mL in Autosampler Vial DHA PONA Standard Select Deselect

Catalog # 30731

Units
ea.  
Conc. in Solvent and Volume
Neat, 0.15 mL in Autosampler Vial  
Product Name
DHA PONA Standard  
Certified Reference Material (CRM)
No  
Shipping Conditions
Ambient  
Storage Temperature
10 °C or colder  

    Compound, Conc (wt/wt%)
    Paraffins
    N-Butane, 2.086%
    N-Decane, 0.966%
    N-Dodecane, 0.943%
    N-Heptane, 2.479%
    N-Hexane, 3.882%
    N-Nonane, 1.048%
    N-Octane, 1.403%
    N-Pentadecane, 0.947%
    N-Pentane, 4.093%
    Propane, 0.251%
    N-Tetradecane, 0.947%
    N-Tridecane, 0.941%
    N-Undecane, 0.941%
    Isoparaffins
    C8 Isoparaffin, 0.004%
    C8 Isoparaffin, 0.007%
    C8 Isoparaffin, 0.009%
    C8 Isoparaffin, 0.018%
    C8 Isoparaffin, 0.029%
    C9 Isoparaffin, 0.018%
    C11 Isoparaffin, 0.004%
    C12 Isoparaffin, 0.008%
    C15 Isoparaffin, 0.007%
    3,3-Diethylpentane, 0.378%
    2,2-Dimethylbutane, 0.233%
    2,3-Dimethylbutane, 0.985%
    2,2-Dimethylheptane, 0.042%
    2,3-Dimethylheptane, 0.242%
    2,4-Dimethylheptane, 0.058%
    2,5-Dimethylheptane, 0.813%
    3,3-Dimethylheptane, 0.355%
    3,4-Dimethylheptane, 0.166%
    3,5-Dimethylheptane, 0.463%
    2,2-Dimethylhexane, 0.155%
    2,3-Dimethylhexane, 0.041%
    2,4-Dimethylhexane, 0.287%
    2,5-Dimethylhexane, 1.156%
    2,2-Dimethyloctane, 0.416%
    2,5-Dimethyloctane, 0.004%
    3,3-Dimethyloctane, 0.158%
    2,2-Dimethylpentane, 0.623%
    2,3-Dimethylpentane, 1.129%
    2,4-Dimethylpentane, 1.356%
    3,3-Dimethylpentane, 0.528%
    2,2-Dimethylpropane, 0.02%
    3-Ethylhexane, 0.103%
    3-Ethyloctane, 0.211%
    3-Ethylpentane, 0.374%
    I9, 0.005%
    I15, 0.004%
    I20, 0.01%
    I24, 0.003%
    I45, 0.007%
    Isobutane, 0.7%
    Isopentane, 3.249%
    2-Methylheptane, 1.286%
    3-Methylheptane, 1.455%
    4-Methylheptane, 0.411%
    2-Methylhexane, 1.909%
    3-Methylhexane, 1.36%
    2-Methylnonane, 0.32%
    3-Methylnonane, 1.047%
    2-Methyloctane, 0.308%
    3-Methyloctane, 1.432%
    2-Methylpentane, 3.408%
    3-Methylpentane, 3.369%
    2,2,3-Trimethylbutane, 0.158%
    2,2,3-Trimethylhexane, 0.064%
    2,2,4-Trimethylhexane, 0.006%
    2,2,3-Trimethylpentane, 0.825%
    Olefins
    1-Decene, 0.197%
    1-Heptene, 0.59%
    cis-2-Heptene, 0.297%
    trans-2-Heptene, 0.046%
    cis-3-Heptene, 0.088%
    trans-3-Heptene, 0.326%
    1-Hexene, 0.978%
    cis-2-Hexene, 0.254%
    trans-2-Hexene, 0.141%
    cis-Hexene-3, 0.008%
    trans-Hexene-3, 0.026%
    2-Methyl-1,3-Butadiene, 0.32%
    2-Methyl-1-Butene, 0.193%
    3-Methyl-1-Butene, 0.133%
    2-Methyl-1-Nonene, 0.297%
    2-Methyl-2-Pentene, 0.299%
    3-Methyl-t-Pentene-2, 0.009%
    4-Methyl-1-Pentene, 0.295%
    1-Nonene, 0.601%
    trans-2-Nonene, 0.199%
    cis-3-Nonene, 0.263%
    trans-3-Nonene, 0.202%
    cis-4-Nonene, 0.379%
    1-Octene, 0.986%
    cis-2-Octene, 0.201%
    trans-2-Octene, 0.3%
    1,4-Pentadiene, 0.004%
    1-Pentene, 0.763%
    cis-2-Pentene, 0.096%
    trans-2-Pentene, 0.248%
    Naphthenes
    N-Butylcyclopentane, 0.008%
    Cyclohexane, 1.422%
    Cyclopentane, 0.532%
    cis-1,2-Dimethylcyclohexane, 0.599%
    trans-1,2-Dimethylcyclohexane, 0.152%
    1c,3-Dimethylcyclohexane, 0.007%
    1c,4-Dimethylcyclohexane, 0.003%
    trans-1,4-Dimethylcyclohexane, 0.344%
    1,1-Dimethylcyclopentane, 0.099%
    trans-1,2-Dimethylcyclopentane, 0.43%
    cis-1,3-Dimethylcyclopentane, 0.174%
    trans-1,3-Dimethylcyclopentane, 0.326%
    Ethylcyclopentane, 0.592%
    1-Ethyl-1-Methylcyclopentane, 0.082%
    2t-Ethylmethylcyclopentane, 0.036%
    Isobutylcyclohexane, 0.207%
    Isobutylcyclopentane, 0.075%
    Isopropylcyclopentane, 0.076%
    Methylcyclohexane, 1.968%
    Methylcyclopentane, 1.238%
    t-1-Methyl-2(4-Methylphenyl)cyclopentane, 0.203%
    t-1-Methyl-2-N-Propylcyclohexane, 0.263%
    N3, 0.004%
    N14, 0.04%
    N26, 0.007%
    N29, 0.004%
    N30, 0.008%
    N37, 0.011%
    N-Propylcyclopentane, 0.25%
    1,1,2-Trimethylcyclohexane, 0.103%
    1,1,4-Trimethylcyclohexane, 0.376%
    ctc-1,2,3-Trimethylcyclohexane, 0.207%
    ctc-1,2,4-Trimethylcyclohexane, 0.06%
    ctt-1,2,4-Trimethylcyclohexane, 0.103%
    ccc-1,3,5-Trimethylcyclohexane, 0.131%
    1,1,2-Trimethylcyclopentane, 0.018%
    1,1,3-Trimethylcyclopentane, 0.044%
    ccc-1,2,3-Trimethylcyclopentane, 0.045%
    ctc-1,2,3-Trimethylcyclopentane, 0.211%
    tcc-1,2,3-Trimethylcyclopentane, 0.032%
    ctc-1,2,4-Trimethylcyclopentane, 0.04%
    Aromatics
    Benzene, 1.752%
    N-Butylbenzene, 0.349%
    sec-Butylbenzene, 0.519%
    tert-Butylbenzene, 0.345%
    tert-1-Butyl-4-Ethylbenzene, 0.348%
    tert-1-Butyl-2-Methylbenzene, 0.349%
    tert-1-Butyl-3,4,5-Trimethylbenzene, 0.563%
    1,4-Diethylbenzene, 0.005%
    1,2-Dimethyl-3-Ethylbenzene, 0.361%
    1,2-Dimethyl-4-Ethylbenzene, 0.153%
    1,3-Dimethyl-2-Ethylbenzene, 0.134%
    1,3-Dimethyl-5-Ethylbenzene, 0.068%
    1,4-Dimethyl-2-Ethylbenzene, 0.348%
    Ethylbenzene, 1.425%
    Hexylbenzene, 0.865%
    Isobutylbenzene, 0.52%
    Isopropylbenzene, 0.353%
    1,2-Di-isopropylbenzene, 0.012%
    2-Methylbutylbenzene, 0.02%
    1,4-Methyl-t-Butylbenzene, 0.004%
    1-Methyl-2-Ethylbenzene, 0.264%
    1-Methyl-3-Ethylbenzene, 0.48%
    1-Methyl-4-Ethylbenzene, 0.357%
    1-Methyl-2-Isopropylbenzene, 0.47%
    1-Methyl-3-Isopropylbenzene, 0.179%
    1-Methyl-4-Isopropylbenzene, 0.692%
    1,4-Methyl-n-Pentylbenzene, 0.006%
    1-Methyl-2-n-Propylbenzene, 0.36%
    1-Methyl-3-n-Propylbenzene, 0.35%
    1-Methyl-4-n-Propylbenzene, 0.348%
    Pentylbenzene, 0.345%
    N-Propylbenzene, 0.519%
    1,2,4,5-Tetramethylbenzene, 0.144%
    Toluene, 3.031%
    1,2,4-Triethylbenzene, 0.171%
    1,3,5-Triethylbenzene, 0.35%
    1,2,4-Trimethylbenzene, 0.362%
    1,3,5-Trimethylbenzene, 0.092%
    m-Xylene, 0.756%
    o-Xylene, 0.57%
    p-Xylene, 0.248%
    Oxygenates
    tert-Butanol, 0.886%
    Ethanol, 5.761%
    Isopropanol, 0.048%
    Methanol, 0.953%
    Methyl Decanoate, 0.019%
    MTBE, 0.476%
    TAME, 1.332%

ASTM Methods D6729, D6730, and D6733 (Determination of Individual Components in Spark Ignition Engine Fuels) are designed for the determination of the individual hydrocarbons present in spark ignition engine fuels, as well as fuel blends containing oxygenates such as methyl tert-butyl ether, ethyl tert-butyl ether, tert-butanol, ethanol, etc.