502.2 MegaMix Standard (54 components)

Includes all target analytes except the six gases, which are available separately as 502.2 Calibration Mix #1.

502.2 MegaMix Standard (54 components)

Select Catalog # below
Catalog # 30431
Availability:
Price:
Total:
Find a Distributor

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog #
30431 ea. 2,000 µg/mL each in P&T methanol, 1 mL/ampul 502.2 CAL2000 MegaMix Mixture Select Deselect
Units
ea.  
Conc. in Solvent and Volume
2,000 µg/mL each in P&T methanol, 1 mL/ampul  
Product Name
502.2 CAL2000 MegaMix Mixture  
Certified Reference Material (CRM)
Yes  
Max Shelf Life on Ship Date
24 months  
Min Shelf Life on Ship Date*
6 months  
Shipping Conditions
Ambient  
Storage Temperature
0 °C or colder  
30432 ea. 200 µg/mL each in P&T methanol, 1 mL/ampul 502.2 CAL200 MegaMix Mixture Select Deselect
Units
ea.  
Conc. in Solvent and Volume
200 µg/mL each in P&T methanol, 1 mL/ampul  
Product Name
502.2 CAL200 MegaMix Mixture  
Certified Reference Material (CRM)
Yes  
Max Shelf Life on Ship Date
24 months  
Min Shelf Life on Ship Date*
6 months  
Shipping Conditions
Ambient  
Storage Temperature
0 °C or colder  

    Benzene (71-43-2)
    Bromobenzene (108-86-1)
    Bromochloromethane (74-97-5)
    Bromodichloromethane (75-27-4)
    Bromoform (75-25-2)
    n-Butylbenzene (104-51-8)
    sec-Butylbenzene (135-98-8)
    tert-Butylbenzene (98-06-6)
    Carbon tetrachloride (56-23-5)
    Chlorobenzene (108-90-7)
    Chloroform (67-66-3)
    2-Chlorotoluene (95-49-8)
    4-Chlorotoluene (106-43-4)
    Dibromochloromethane (124-48-1)
    1,2-Dibromo-3-chloropropane (DBCP) (96-12-8)
    1,2-Dibromoethane (EDB) (106-93-4)
    Dibromomethane (74-95-3)
    1,2-Dichlorobenzene (95-50-1)
    1,3-Dichlorobenzene (541-73-1)
    1,4-Dichlorobenzene (106-46-7)
    1,1-Dichloroethane (75-34-3)
    1,2-Dichloroethane (107-06-2)
    1,1-Dichloroethene (75-35-4)
    cis-1,2-Dichloroethene (156-59-2)
    trans-1,2-Dichloroethene (156-60-5)
    1,2-Dichloropropane (78-87-5)
    1,3-Dichloropropane (142-28-9)
    2,2-Dichloropropane (594-20-7)
    1,1-Dichloropropene (563-58-6)
    cis-1,3-Dichloropropene (10061-01-5)
    trans-1,3-Dichloropropene (10061-02-6)
    Ethylbenzene (100-41-4)
    Hexachloro-1,3-butadiene (hexachlorobutadiene) (87-68-3)
    Isopropylbenzene (cumene) (98-82-8)
    4-Isopropyltoluene (p-cymene) (99-87-6)
    Methylene chloride (dichloromethane) (75-09-2)
    Naphthalene (91-20-3)
    n-Propylbenzene (103-65-1)
    Styrene (100-42-5)
    1,1,1,2-Tetrachloroethane (630-20-6)
    1,1,2,2-Tetrachloroethane (79-34-5)
    Tetrachloroethene (127-18-4)
    Toluene (108-88-3)
    1,2,3-Trichlorobenzene (87-61-6)
    1,2,4-Trichlorobenzene (120-82-1)
    1,1,1-Trichloroethane (71-55-6)
    1,1,2-Trichloroethane (79-00-5)
    Trichloroethene (79-01-6)
    1,2,3-Trichloropropane (96-18-4)
    1,2,4-Trimethylbenzene (95-63-6)
    1,3,5-Trimethylbenzene (108-67-8)
    m-Xylene (108-38-3)
    o-Xylene (95-47-6)
    p-Xylene (106-42-3)