Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.
Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.
Share:

CLP VOA CAL2000 MegaMix Standard (28 components)

CLP VOA CAL2000 MegaMix Standard (28 components)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
30632 ea. 2,000 µg/mL each in P&T methanol, 1 mL/ampul CLP VOA CAL2000 MegaMix Select Deselect

Catalog # 30632

Units
ea.  
Conc. in Solvent and Volume
2,000 µg/mL each in P&T methanol, 1 mL/ampul  
Product Name
CLP VOA CAL2000 MegaMix  
Certified Reference Material (CRM)
Yes  
Max Shelf Life on Ship Date
60 months  
Min Shelf Life on Ship Date*
6 months  
Shipping Conditions
Ambient  
Storage Temperature
0 °C or colder  

    Benzene (71-43-2)
    Bromodichloromethane (75-27-4)
    Bromoform (75-25-2)
    Carbon disulfide (75-15-0)
    Carbon tetrachloride (56-23-5)
    Chlorobenzene (108-90-7)
    Chloroform (67-66-3)
    Dibromochloromethane (124-48-1)
    1,1-Dichloroethane (75-34-3)
    1,2-Dichloroethane (107-06-2)
    1,1-Dichloroethene (75-35-4)
    cis-1,2-Dichloroethene (156-59-2)
    trans-1,2-Dichloroethene (156-60-5)
    1,2-Dichloropropane (78-87-5)
    cis-1,3-Dichloropropene (10061-01-5)
    trans-1,3-Dichloropropene (10061-02-6)
    Ethylbenzene (100-41-4)
    Methylene chloride (dichloromethane) (75-09-2)
    Styrene (100-42-5)
    1,1,2,2-Tetrachloroethane (79-34-5)
    Tetrachloroethene (127-18-4)
    Toluene (108-88-3)
    1,1,1-Trichloroethane (71-55-6)
    1,1,2-Trichloroethane (79-00-5)
    Trichloroethene (79-01-6)
    m-Xylene (108-38-3)
    o-Xylene (95-47-6)
    p-Xylene (106-42-3)

Why don’t MegaMix mixtures contain ketones required by the methods?
In methanol solution, ketones can interact with other compounds, resulting in a methoxy addition to the ketone.[1] The presence of halogenated compounds greatly speeds the reaction, limiting shelf-life to less than two months. Because none of eighteen preservatives (including water) was successful at inhibiting the reaction, we do not combine ketones with halogenated compounds in any of our calibration mixtures.
[1] A comparison of ketone stability in calibration mixes for EPA Method 524.2 Revision 4.0, Christopher Cox, et. al., 1997 Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, poster number 467P.