TO-15 65 Component Mix (65 components)

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)—meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

Ordering Notes

Gas standards are subject to hazardous materials shipping fees by most freight carriers. All calibration gas standards are nonreturnable due to DOT hazardous shipping requirements.

Certificates of analysis for this product are provided electronically. To view and download your certificate, simply visit www.restek.com/documentation

TO-15 65 Component Mix (65 components)

Catalog # 34436

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
34436 ea. 1 ppm in nitrogen, 104 liters @ 1,800 psig TO-15 65 Component Mix Select Deselect

Catalog # 34436

Units
ea.  
Conc. in Solvent and Volume
1 ppm in nitrogen, 104 liters @ 1,800 psig  
Product Name
TO-15 65 Component Mix  
Product Grade
Blend tolerance: ±10%; Analytical accuracy: ±5%  
Shelf Life
1 yr  
26359 ea. 1 ppm in nitrogen, 110 liters @ 1,800 psig TO-15 65 Component Mix Select Deselect

Catalog # 26359

Units
ea.  
Conc. in Solvent and Volume
1 ppm in nitrogen, 110 liters @ 1,800 psig  
Product Name
TO-15 65 Component Mix  
Product Grade
Blend tolerance: ±10%; Analytical accuracy: ±5%  
Shelf Life
1 yr  
26360 ea. 100 ppb in nitrogen, 110 liters @ 1,800 psig TO-15 65 Component Mix Select Deselect

Catalog # 26360

Units
ea.  
Conc. in Solvent and Volume
100 ppb in nitrogen, 110 liters @ 1,800 psig  
Product Name
TO-15 65 Component Mix  
Product Grade
Blend tolerance: ±20%; Analytical accuracy: ±10%  
Shelf Life
1 yr  
34436-PI ea. TPED (Pi) compliant 1 ppm in nitrogen, 110 liters @ 1,800 psig TO-15 65 Component Mix Select Deselect

Catalog # 34436-PI

Units
ea.  
Certification/Compliance
TPED (Pi) compliant  
Conc. in Solvent and Volume
1 ppm in nitrogen, 110 liters @ 1,800 psig  
Product Name
TO-15 65 Component Mix  
Product Grade
Blend tolerance: ±10%; Analytical accuracy: ±5%  
Shelf Life
1 yr  
34437-PI ea. TPED (Pi) compliant 100 ppb in nitrogen, 110 liters @ 1,800 psig TO-15 65 Component Mix Select Deselect

Catalog # 34437-PI

Units
ea.  
Certification/Compliance
TPED (Pi) compliant  
Conc. in Solvent and Volume
100 ppb in nitrogen, 110 liters @ 1,800 psig  
Product Name
TO-15 65 Component Mix  
Product Grade
Blend tolerance: ±20%; Analytical accuracy: ±10%  
Shelf Life
1 yr  

Each of these gas standards comes with a certificate of analysis and unique serial number. All cylinders are disposable and do not require rental or demurrage fees. Recertification of cylinders is available directly with our suppliers. All cylinders are drop-shipped from our suppliers to provide fast delivery and the "freshest" standard possible. Minimum 12-month stability on all cylinders.

Acetone
Acrolein
Benzene
Benzyl chloride*
Bromodichloromethane
Bromoform
Bromomethane
1,3-Butadiene
2-Butanone (MEK)
Carbon disulfide*
Carbon tetrachloride
Chlorobenzene
Chloroethane
Chloroform
Chloromethane
Cyclohexane
Dibromochloromethane
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
1,1-Dichloroethane
1,2-Dichloroethane
1,1-Dichloroethene
cis-1,2-Dichloroethene
trans-1,2-Dichloroethene
1,2-Dichloropropane
cis-1,3-Dichloropropene
trans-1,3-Dichloropropene
1,4-Dioxane
Ethanol*
Ethyl acetate
Ethylbenzene
Ethylene dibromide (1,2-dibromoethane)
4-Ethyltoluene
Trichlorofluoromethane (Freon 11)
Dichlorodifluoromethane (Freon 12 )
1,1,2-Trichloro-1,2,2-trifluoroethane (Freon 113)
1,2-Dichlorotetrafluoroethane (Freon 114)
Heptane
Hexachloro-1,3-butadiene
Hexane
2-Hexanone (MBK)
4-Methyl-2-pentanone (MIBK)
Methylene chloride
Methyl tert-butyl ether (MTBE)
Methyl methacrylate
Naphthalene
2-Propanol
Propylene
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethene
Tetrahydrofuran
Toluene
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethene
1,2,4-Trimethylbenzene
1,3,5-Trimethylbenzene
Vinyl acetate
Vinyl chloride
m-Xylene
o-Xylene
p-Xylene

Spectra (Linde) 104 L Cylinders:
Aluminum construction
Size: 8 x 24 cm
Volume/Pressure: 104 liters of gas @ 1800 psig (124 bar)
Outlet Fitting: CGA-180
Weight: 1.5 lb/0.7 kg

Airgas 110 L Cylinders (PI-marked Cylinders for EU Regulations):
Aluminum construction
Size: 8.3 x 29.5 cm
Volume/Pressure: 110 liters of gas @ 1800 psig (124 bar)
Outlet Fitting: CGA-180
Weight: 2.2 lb/1 kg
U.S. DOT Specs: 3AL2216

*Stability of this compound cannot be guaranteed.