Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.

Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Tedlar Sampling Bags

  • Find the bags you need—we offer sizes from 0.5 L to 100 L.
  • Lightweight and easy to use.
  • Available with polypropylene or stainless-steel valve; choose bags with a septum fitting for syringe sampling or standard spiking.
  • Maximum operating temperature: 82 °C (180 °F) with polypropylene valves or 202 °C (397 °F) with stainless steel valves.

Note: Use only Point Style 5 or H syringe needles.

Tedlar Sampling Bags

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
22049 10-pk. 0.5 L 6" x 6" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22049

Units
10-pk.  
Volume
0.5 L  
Dimensions
6" x 6"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22050 10-pk. 1 L 7" x 7" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22050

Units
10-pk.  
Volume
1 L  
Dimensions
7" x 7"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22051 10-pk. 3 L 9.5" x 10" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22051

Units
10-pk.  
Volume
3 L  
Dimensions
9.5" x 10"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22052 10-pk. 5 L 12" x 12.5" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22052

Units
10-pk.  
Volume
5 L  
Dimensions
12" x 12.5"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22053 10-pk. 10 L 11.75" x 22" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22053

Units
10-pk.  
Volume
10 L  
Dimensions
11.75" x 22"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22054 10-pk. 12 L 13" x 24" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22054

Units
10-pk.  
Volume
12 L  
Dimensions
13" x 24"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22055 5-pk. 25 L 17.5" x 24" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22055

Units
5-pk.  
Volume
25 L  
Dimensions
17.5" x 24"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22056 5-pk. 40 L 24" x 24.25" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22056

Units
5-pk.  
Volume
40 L  
Dimensions
24" x 24.25"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22057 5-pk. 80 L 28.25" x 30.5" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22057

Units
5-pk.  
Volume
80 L  
Dimensions
28.25" x 30.5"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
22058 3-pk. 100 L 28" x 36" Polypropylene Valve and Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 22058

Units
3-pk.  
Volume
100 L  
Dimensions
28" x 36"  
Modification
Polypropylene Valve and Septum Fitting  
Product Name
Tedlar Sampling Bag  
27380 10-pk. 0.5 L 6" x 6" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27380

Units
10-pk.  
Volume
0.5 L  
Dimensions
6" x 6"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22038
27381 10-pk. 1 L 7" x 7" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27381

Units
10-pk.  
Volume
1 L  
Dimensions
7" x 7"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
27382 10-pk. 3 L 9.5" x 10" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27382

Units
10-pk.  
Volume
3 L  
Dimensions
9.5" x 10"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
27383 10-pk. 5 L 12" x 12.5" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27383

Units
10-pk.  
Volume
5 L  
Dimensions
12" x 12.5"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
27384 10-pk. 10 L 11.75" x 22" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27384

Units
10-pk.  
Volume
10 L  
Dimensions
11.75" x 22"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22042
27385 10-pk. 12 L 13" x 24" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27385

Units
10-pk.  
Volume
12 L  
Dimensions
13" x 24"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22043
27386 5-pk. 25 L 17.5" x 24" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27386

Units
5-pk.  
Volume
25 L  
Dimensions
17.5" x 24"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22044
27387 5-pk. 40 L 24" x 24.25" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27387

Units
5-pk.  
Volume
40 L  
Dimensions
24" x 24.25"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
27388 3-pk. 80 L 28.25" x 30.5" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27388

Units
3-pk.  
Volume
80 L  
Dimensions
28.25" x 30.5"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
27389 3-pk. 100 L 28" x 36" Stainless Steel Push/Pull Valve & Septum Fitting Tedlar Sampling Bag Select Deselect

Catalog # 27389

Units
3-pk.  
Volume
100 L  
Dimensions
28" x 36"  
Modification
Stainless Steel Push/Pull Valve & Septum Fitting  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22047
27390 10-pk. 0.5 L 6" x 6" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27390

Units
10-pk.  
Volume
0.5 L  
Dimensions
6" x 6"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22038
27391 10-pk. 1 L 7" x 7" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27391

Units
10-pk.  
Volume
1 L  
Dimensions
7" x 7"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
27392 10-pk. 3 L 9.5" x 10" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27392

Units
10-pk.  
Volume
3 L  
Dimensions
9.5" x 10"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
27393 10-pk. 5 L 12" x 12.5" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27393

Units
10-pk.  
Volume
5 L  
Dimensions
12" x 12.5"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
27394 5-pk. 10 L 11.75" x 22" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27394

Units
5-pk.  
Volume
10 L  
Dimensions
11.75" x 22"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22042
27395 5-pk. 12 L 13" x 24" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27395

Units
5-pk.  
Volume
12 L  
Dimensions
13" x 24"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22043
27396 5-pk. 25 L 17.5" x 24" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27396

Units
5-pk.  
Volume
25 L  
Dimensions
17.5" x 24"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22044
27397 5-pk. 40 L 24" x 24.25" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27397

Units
5-pk.  
Volume
40 L  
Dimensions
24" x 24.25"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
27398 3-pk. 80 L 28.25" x 30.5" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27398

Units
3-pk.  
Volume
80 L  
Dimensions
28.25" x 30.5"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
27399 3-pk. 100 L 28" x 36" Stainless Steel Push/Pull Valve Only Tedlar Sampling Bag Select Deselect

Catalog # 27399

Units
3-pk.  
Volume
100 L  
Dimensions
28" x 36"  
Modification
Stainless Steel Push/Pull Valve Only  
Product Name
Tedlar Sampling Bag  
Similar To
Restek (Discontinued) 22047

Sampling bags are low-cost, whole-air sampling devices for VOCs and permanent gases. Several EPA, NIOSH, and OSHA methods exist for bag sampling for a variety of applications: stationary sources emissions; workplace atmospheres; ambient, indoor air quality; and breath analysis. Choose the valve type appropriate for your application. A single eyelet provides handling convenience.
Physical Specifications
Composition: polyvinyl fluoride (PVF) polymer resin
Thickness: 0.002"
Tensile Strength: 8,000 psi
Max. Operating Temp.: 82 °C (180 °F) with polypropylene valves or 202 °C (397 °F) with stainless steel valves
Specific Gravity: 1.7 g/mL
Oxygen Permeability: 50 cc/m2/day
Water Vapor Permeability: 9–57 g/m2/day
Carbon Dioxide Permeability: 172 cc/m2/day