RAVEqc Quick-Connect Air Valves

  • Simplify your workflow—tool-free design makes it fast and easy for anyone to make consistent, quality connections.
  • Extend air canister and valve lifetime—no wrenches mean no overtightening or cross-threading damage.
  • Stand-alone or supporting roles—use alone or pair with a bellows/diaphragm valve for the ultimate in sample security and convenience.
  • Check status at a glance—if the parts are connected, the valve is open; if they’re apart, it’s closed. (Open-position valves also available.*)
  • Standard compression or tube end fittings accommodate a wide variety of air canisters and related devices.
  • Leak-free performance—each and every valve is helium leak tested to 1x10-6 mL/sec.
  • Compatible with Entech Micro-QT valves.

Note: A RAVEqc valve bracket is required for use with Restek 1, 3, 6, and 15 L air sampling canisters when using the compression fitting mounted directly on the 1/4" canister tube stub. This bracket is not needed when using Restek miniature canisters or Entech canisters.

Documentation and Instructions Sheets

RAVEqc Quick-Connect Air Valves

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
27341 Stainless Steel ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/16" Male Compression Fitting Select Deselect

Catalog # 27341

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/16" Male Compression Fitting  
Similar To
Entech FQT-100

Products Often Purchased with Female RAVEqc Valve to 1/16” Male Compression Fitting

27342 Siltek Treated ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/16" Male Compression Fitting Select Deselect

Catalog # 27342

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/16" Male Compression Fitting  
Similar To
Entech FQT-100S

Products Often Purchased with Female RAVEqc Valve to 1/16” Male Compression Fitting, Siltek treated

27343 Stainless Steel ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/8" Male Compression Fitting Select Deselect

Catalog # 27343

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/8" Male Compression Fitting  
Similar To
Entech FQT-200

Products Often Purchased with Female RAVEqc Valve to 1/8” Male Compression Fitting

27344 Siltek Treated ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/8" Male Compression Fitting Select Deselect

Catalog # 27344

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/8" Male Compression Fitting  
Similar To
Entech FQT-200S

Products Often Purchased with Female RAVEqc Valve to 1/8” Male Compression Fitting, Siltek treated

27345 Stainless Steel ea. 3,850 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position Select Deselect

Catalog # 27345

Material
Stainless Steel  
Units
ea.  
Flow Capacity
3,850 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position  

Products Often Purchased with Female RAVEqc Valve to 1/4” Male Compression Fitting - High Flow, Open position

27346 Siltek Treated ea. 3,850 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position Select Deselect

Catalog # 27346

Material
Siltek Treated  
Units
ea.  
Flow Capacity
3,850 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position  

Products Often Purchased with Female RAVEqc Valve to 1/4” Male Compression Fitting - High Flow, Open position, Siltek Treated

27347 Stainless Steel ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" Tube-End Fitting Select Deselect

Catalog # 27347

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" Tube-End Fitting  
Similar To
Entech FQT-T400

Products Often Purchased with Female RAVEqc Valve to ¼” male Tube fitting

27348 Siltek Treated ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" Tube-End Fitting Select Deselect

Catalog # 27348

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" Tube-End Fitting  
Similar To
Entech FQT-T400S

Products Often Purchased with Female RAVEqc Valve to ¼” male Tube fitting - Siltek Treated

27349 Stainless Steel ea. 2,500 mL/min @ 29" Hg Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge Select Deselect

Catalog # 27349

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge  
Similar To
Entech MQT-400L-D

Products Often Purchased with Male RAVEqc 3 Port Valve to ¼” Male Compression fitting without Gauge

27350 Siltek Treated ea. 2,500 mL/min @ 29" Hg Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge Select Deselect

Catalog # 27350

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge  
Similar To
Entech MQT-400L-DS

Products Often Purchased with Male RAVEqc 3 Port Valve to ¼” Male Compression fitting without Gauge, Siltek Treated

27351 Stainless Steel ea. 2,500 mL/min @ 29" Hg Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge Select Deselect

Catalog # 27351

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge  
Similar To
Entech MQT-400L-G

Products Often Purchased with Male RAVEqc 3 Port Valve to ¼” Male Compression fitting with Gauge

27352 Siltek Treated ea. 2,500 mL/min @ 29" Hg Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge Select Deselect

Catalog # 27352

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge  
Similar To
Entech MQT-400L-GS

Products Often Purchased with Male RAVEqc 3 Port Valve to ¼” Male Compression fitting with Gauge, Siltek Treated

27365 Stainless Steel ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" NPT Fitting Select Deselect

Catalog # 27365

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" NPT Fitting  

Products Often Purchased with Female RAVEqc Valve to 1/4" NPT Fitting, Stainless Steel

27366 Siltek Treated ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" NPT Fitting Select Deselect

Catalog # 27366

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" NPT Fitting  

Products Often Purchased with Female RAVEqc Valve to 1/4" NPT Fitting, Siltek Treated

27367 Stainless Steel ea. 2,500 mL/min @ 29" Hg Male RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27367

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Male RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Restek (Discontinued) 24185
Entech MQT-400

Products Often Purchased with Male RAVEqc Valve to 1/4" Male Compression Fitting

27368 Siltek Treated ea. 2,500 mL/min @ 29" Hg Male RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27368

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Male RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Restek (Discontinued) 24186
Entech MQT-400S

Products Often Purchased with Male RAVEqc Valve to 1/4" Male Compression Fitting, Siltek Treated

27369 Stainless Steel ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27369

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Restek (Discontinued) 24187
Entech FQT-400

Products Often Purchased with Female RAVEqc Valve to 1/4" Male Compression Fitting

27370 Siltek Treated ea. 2,500 mL/min @ 29" Hg Female RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27370

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Entech FQT-400S

Products Often Purchased with Female RAVEqc Valve to 1/4" Male Compression Fitting, Siltek Treated

27371 Stainless Steel ea. 2,500 mL/min @ 29" Hg Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58") Select Deselect

Catalog # 27371

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58")  
Similar To
Entech MQT-T400
27372 Siltek Treated ea. 2,500 mL/min @ 29" Hg Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58") Select Deselect

Catalog # 27372

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58")  
Similar To
Entech MQT-T400S

Products Often Purchased with Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58"), Siltek Treated

27373 Stainless Steel ea. 2,500 mL/min @ 29" Hg Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23") Select Deselect

Catalog # 27373

Material
Stainless Steel  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23")  
Similar To
Entech MQT-ST400
27374 Siltek Treated ea. 2,500 mL/min @ 29" Hg Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23") Select Deselect

Catalog # 27374

Material
Siltek Treated  
Units
ea.  
Flow Capacity
2,500 mL/min @ 29" Hg  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23")  
Similar To
Entech MQT-ST400S

Products Often Purchased with Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23"), Siltek Treated

  • RAVEqc Quick-Connect air valves are a fast, easy, tool-free way to attach air canisters to the wide variety of devices used to sample and analyze air samples.
  • Restek Air Valve Excellence (RAVE) is a great family of products that upgrade your existing air canisters to improve reliability and performance.
  • Made in the U.S.A.
Valve Max Flow @ 29" Hg (mL/min)** 6 L Grab Sample Time (sec)
RAVEqc quick-connect air valve 2500 240
RAVEqc high-flow quick-connect air valve 3850 120
RAVE diaphragm valve 40,000 10
** Flow rates calculated on a 1/4" platform.

* Open-position option available to prevent vacuum/pressure from being trapped by the valve when desired (e.g., when using a vacuum/pressure gauge). High flow facilitates use with canister-cleaning ovens.