Restek PAL SPME Fibers

  • Suitable for a wide range of analyte chemistries and sample matrices.
  • Reliable performance meets or exceeds other brands.
  • Robust aluminum hub is more durable than plastic.
  • Optimized for PAL system autosamplers and compatible with most GC inlets.
  • SPME automated sample preparation reduces sample handling and solvent consumption.
Documentation and Instructions Sheets

Restek PAL SPME Fibers

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
27478.1 85 µm Polyacrylate (PA) Fiber, Polar ea. Gray 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27478.1

Material
85 µm Polyacrylate (PA) Fiber, Polar  
Units
ea.  
Color
Gray  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–White
27478.3 85 µm Polyacrylate (PA) Fiber, Polar 3-pk. Gray 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27478.3

Material
85 µm Polyacrylate (PA) Fiber, Polar  
Units
3-pk.  
Color
Gray  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–White
27478.5 85 µm Polyacrylate (PA) Fiber, Polar 5-pk. Gray 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27478.5

Material
85 µm Polyacrylate (PA) Fiber, Polar  
Units
5-pk.  
Color
Gray  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–White
27479.1 95 µm Carbon Wide Range (WR)/PDMS Fiber ea. Dark Blue 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27479.1

Material
95 µm Carbon Wide Range (WR)/PDMS Fiber  
Units
ea.  
Color
Dark Blue  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Black
27479.3 95 µm Carbon Wide Range (WR)/PDMS Fiber 3-pk. Dark Blue 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27479.3

Material
95 µm Carbon Wide Range (WR)/PDMS Fiber  
Units
3-pk.  
Color
Dark Blue  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Black
27479.5 95 µm Carbon Wide Range (WR)/PDMS Fiber 5-pk. Dark Blue 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27479.5

Material
95 µm Carbon Wide Range (WR)/PDMS Fiber  
Units
5-pk.  
Color
Dark Blue  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Black
27480.1 100 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar ea. Red 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27480.1

Material
100 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
ea.  
Color
Red  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Red
27480.3 100 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar 3-pk. Red 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27480.3

Material
100 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
3-pk.  
Color
Red  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Red
27480.5 100 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar 5-pk. Red 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27480.5

Material
100 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
5-pk.  
Color
Red  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Red
27481.1 30 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar ea. Golden 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27481.1

Material
30 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
ea.  
Color
Golden  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Yellow
27481.3 30 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar 3-pk. Golden 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27481.3

Material
30 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
3-pk.  
Color
Golden  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Yellow
27481.5 30 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar 5-pk. Golden 280 °C SPME Fiber 200–280 °C Select Deselect

Catalog # 27481.5

Material
30 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
5-pk.  
Color
Golden  
Max Temp
280 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–280 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Yellow
27482.1 7 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar ea. Green 340 °C SPME Fiber 200–340 °C Select Deselect

Catalog # 27482.1

Material
7 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
ea.  
Color
Green  
Max Temp
340 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–340 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Green
27482.3 7 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar 3-pk. Green 340 °C SPME Fiber 200–340 °C Select Deselect

Catalog # 27482.3

Material
7 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
3-pk.  
Color
Green  
Max Temp
340 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–340 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Green
27482.5 7 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar 5-pk. Green 340 °C SPME Fiber 200–340 °C Select Deselect

Catalog # 27482.5

Material
7 µm Polydimethylsiloxane (PDMS) Fiber, Nonpolar  
Units
5-pk.  
Color
Green  
Max Temp
340 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
200–340 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Green
27483 Set of 5 Method Development SPME Fiber Kit Select Deselect

Catalog # 27483

Units
Set of 5  
Includes
one SPME fiber each: PDMS 7 µm, PDMS 30 µm, PDMS 100 µm, PA 85 µm, Carbon WR/PDMS 95 µm  
Product Name
Method Development SPME Fiber Kit  
27873.1 80 µm (50 DVB / 30 Carbon WR)/PDMS Fiber ea. Dark Gray 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27873.1

Material
80 µm (50 DVB / 30 Carbon WR)/PDMS Fiber  
Units
ea.  
Color
Dark Gray  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Gray
27873.3 80 µm (50 DVB / 30 Carbon WR)/PDMS Fiber 3-pk. Dark Gray 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27873.3

Material
80 µm (50 DVB / 30 Carbon WR)/PDMS Fiber  
Units
3-pk.  
Color
Dark Gray  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Gray
27873.5 80 µm (50 DVB / 30 Carbon WR)/PDMS Fiber 5-pk. Dark Gray 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27873.5

Material
80 µm (50 DVB / 30 Carbon WR)/PDMS Fiber  
Units
5-pk.  
Color
Dark Gray  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Gray
27874.1 65 µm Divinylbenzene (DVB)/PDMS Fiber ea. Violet 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27874.1

Material
65 µm Divinylbenzene (DVB)/PDMS Fiber  
Units
ea.  
Color
Violet  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Blue
27874.3 65 µm Divinylbenzene (DVB)/PDMS Fiber 3-pk. Violet 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27874.3

Material
65 µm Divinylbenzene (DVB)/PDMS Fiber  
Units
3-pk.  
Color
Violet  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Blue
27874.5 65 µm Divinylbenzene (DVB)/PDMS Fiber 5-pk. Violet 300 °C SPME Fiber 220–300 °C Select Deselect

Catalog # 27874.5

Material
65 µm Divinylbenzene (DVB)/PDMS Fiber  
Units
5-pk.  
Color
Violet  
Max Temp
300 °C  
Product Name
SPME Fiber  
Recommended Operating Temp
220–300 °C  
Similar To
Supelco/Millipore Sigma Hub Color–Blue

Solid phase microextraction (SPME) is an automated sample preparation technique that reduces sample handling and solvent consumption. SPME technology has many applications in environmental, food, clinical, and other industries. Restek PAL SPME fibers are high-performing fibers that meet or exceed the performance of other brands. Our reliable SPME fibers are optimized for PAL system autosamplers and are compatible with most GC inlets. Restek SPME fibers are suitable for a wide range of analyte chemistries and sample matrices.

Our SPME product line is continually expanding, and our current products and recommended uses include the following.

  • 7 µm PDMS fibers are recommended for nonpolar, high molecular weight analytes (125–600 Da).
  • 30 µm PDMS fibers are recommended for nonpolar, semivolatile analytes (80–500 Da).
  • 100 µm PDMS fibers are recommended for volatile analytes (60–275 Da).
  • 85 µm Polyacrylate fibers are recommended for polar, semivolatile analytes (80–300 Da).
  • 95 µm Carbon Wide Range (WR)/PDMS fibers are recommended for gases and highly volatile low molecular weight analytes (30–225).
  • 65 μm Divinylbenzene (DVB)/PDMS fibers are recommended for aromatic semivolatile analytes (50–300 Da).
  • 80 μm DVB/Carbon WR/PDMS fibers are recommended for volatile and semivolatile analytes (40–275 Da).

Recommended maximum GC inlet pressure is 50 psi or less.

All Restek PAL SPME fibers are 10 mm in length and are housed in a 23-gauge needle. The phase is bonded onto a fused silica fiber core.