27355 |
|
|
kit |
|
|
for Shimadzu GC-2010 Split/Splitless Injector (not compatible with SE or Plus models) |
|
Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Shimadzu GC-2010 Split/Splitless Injector (not compatible with SE or Plus models)
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23279); 1.1 mm Microseal (cat.# 23232); Port Weldment (cat.# 27500 ); Adaptor Cup (cat.# 27497); Adaptor Kit (cat.# 23229)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal
|
27356 |
|
|
kit |
|
|
for Agilent 6890 Split/Splitless Injector (for canister-type filters) |
|
Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Agilent 6890 Split/Splitless Injector (for canister-type filters)
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23280); 1.1 mm Microseal (cat.# 23232); Split/Splitless Weldment; Large Canister Type Filter (cat.# 27502 ); Adaptor Cup (cat.# 27496); Nut (cat.# 23228)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal
|
27357 |
|
|
kit |
|
|
for Agilent 7890 Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Agilent 7890 Split/Splitless Injector
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23280); 1.1 mm Microseal (cat.# 23232); Agilent Weldment (cat.# 27504); Adaptor Cup (cat.# 27496); Nut (cat.# 23228)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal
|
27358 |
|
|
kit |
|
|
for Thermo TRACE 1300/1310 Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Thermo TRACE 1300/1310 Split/Splitless Injector
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23278); 1.1 mm Microseal (cat.# 23232); Liner Cap/Septum Holder (cat.# 27506); Adaptor Cup (cat.# 27498); Nut (cat.# 23230)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal
|
27359 |
|
|
kit |
|
|
for Thermo TRACE Ultra Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Thermo TRACE Ultra Split/Splitless Injector
- Includes
- 2.0 mm ID straight inlet liner, 5-pk. (cat.# 22267); 1.1 mm Microseal (cat.# 23232); Liner Cap (cat.# 27508); Adaptor Cup (cat.# 27499); Adaptor Kit (cat.# 23231)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.1 mm Merlin Microseal
|
27360 |
|
|
kit |
|
|
for Shimadzu GC-2010 Split/Splitless Injector (not compatible with SE or Plus models) |
|
Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Shimadzu GC-2010 Split/Splitless Injector (not compatible with SE or Plus models)
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23279); 1.5 mm Microseal (cat.# 23233); Port Weldment (cat.# 27500); Adaptor Cup (cat.# 27497); Adaptor Kit (cat.# 23229)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal
|
27361 |
|
|
kit |
|
|
for Agilent 6890 Split/Splitless Injector (for canister-type filters) |
|
Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Agilent 6890 Split/Splitless Injector (for canister-type filters)
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23280); 1.5 mm Microseal (cat.# 23233); Split/Splitless Weldment and Large Canister Type Filter (cat.# 27502); Adaptor Cup (cat.# 27496); Nut (cat.# 23228)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal
|
27362 |
|
|
kit |
|
|
for Agilent 7890 Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Agilent 7890 Split/Splitless Injector
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23280); 1.5 mm Microseal (cat.# 23233); Agilent Weldment (cat.# 27504); Adaptor Cup (cat.# 27496); Nut (cat.# 23228)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal
|
27363 |
|
|
kit |
|
|
for Thermo TRACE 1300/1310 Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Thermo TRACE 1300/1310 Split/Splitless Injector
- Includes
- Topaz 1.8 mm ID Straight/SPME inlet liner, 5-pk. (cat.# 23278); 1.5 mm Microseal (cat.# 23233); Liner Cap/Septum Holder (cat.# 27506); Adaptor Cup (cat.# 27498); Adaptor Kit (cat.# 23230)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal
|
27364 |
|
|
kit |
|
|
for Thermo TRACE Ultra Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Thermo TRACE Ultra Split/Splitless Injector
- Includes
- 2.0 mm ID straight inlet liner, 5-pk. (cat.# 22267); 1.5 mm Microseal (cat.# 23233); Liner Cap (cat.# 27508); Adaptor Cup (cat.# 27499); Adaptor Kit (cat.# 23231)
- Product Name
- Restek PAL SPME Arrow Conversion Kit with 1.5 mm Merlin Microseal
|
27491 |
|
|
kit |
|
|
for Shimadzu GC-2010 Split/Splitless Injector (not compatible with SE or Plus models) |
|
Restek PAL SPME Arrow Conversion Kit |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Shimadzu GC-2010 Split/Splitless Injector (not compatible with SE or Plus models)
- Includes
- Topaz 1.8 mm ID straight/SPME inlet liner, 5-pk. (cat.# 23279); Thermolite Plus septa, 3 pk. (cat.# 23872); Injection port weldment (cat.# 27500); Needle guide/septum nut (cat.# 27501); Injector adaptor cup (cat.# 27497)
- Product Name
- Restek PAL SPME Arrow Conversion Kit
|
27492 |
|
|
kit |
|
|
for Agilent 6890 Split/Splitless Injector (for canister-type filters) |
|
Restek PAL SPME Arrow Conversion Kit |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Agilent 6890 Split/Splitless Injector (for canister-type filters)
- Includes
- Topaz 1.8 mm ID straight/SPME inlet liner, 5-pk. (cat.# 23280); Thermolite Plus septa, 3-pk. (cat.# 23864); Split/splitless weldment; large, canister-type filter (cat.# 27502); Septum nut for 6890 split/splitless weldments (cat.# 27503); Injector adaptor cup (cat.# 27496)
- Product Name
- Restek PAL SPME Arrow Conversion Kit
|
27493 |
|
|
kit |
|
|
for Agilent 7890 Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Agilent 7890 Split/Splitless Injector
- Includes
- Topaz 1.8 mm ID straight/SPME inlet liner, 5-pk. (cat.# 23280); Thermolite Plus septa, 3-pk. (cat.# 23864); Agilent split/splitless weldment and septum nut (cat.# 27504); Injector adaptor cup (cat.# 27496)
- Product Name
- Restek PAL SPME Arrow Conversion Kit
|
27494 |
|
|
kit |
|
|
for Thermo TRACE 1300/1310 Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Thermo TRACE 1300/1310 Split/Splitless Injector
- Includes
- Topaz 1.8 mm ID straight/SPME inlet liner, 5-pk. (cat.# 23278); Premium nonstick BTO septa, 3-pk. (cat.# 27090); Septum cap (cat.# 27505); Liner cap/septum holder (cat.# 27506); Injector adaptor cup (cat.# 27498)
- Product Name
- Restek PAL SPME Arrow Conversion Kit
|
27495 |
|
|
kit |
|
|
for Thermo TRACE Ultra Split/Splitless Injector |
|
Restek PAL SPME Arrow Conversion Kit |
|
|
Select
Deselect
|
- Units
- kit
- Instrument
- for Thermo TRACE Ultra Split/Splitless Injector
- Includes
- 2.0 mm ID straight inlet liner, 5-pk. (cat.# 22267); Premium nonstick BTO septa, 3-pk. (cat.# 27096); Septum holder and support (cat.# 27507); Liner cap (cat.# 27508); Injector adaptor cup (cat.# 27499)
- Product Name
- Restek PAL SPME Arrow Conversion Kit
|