Revive In-Line Sample Preparation (ILSP)

  • Automated, in-line sample extract cleanup dramatically reduces sample preparation time.
  • Simultaneous analysis and ILSP cartridge wash eliminate downtime between samples.
  • Fast, simple alternative to QuEChERS or SPE for multiresidue pesticides analysis in foods.
  • Minimizes money spent on disposable sample preparation products and associated waste.
  • Reduces sources of error and variability related to manual cleanup.

Revive In-Line Sample Preparation (ILSP)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
27880 ea. Revive ILSP holder for 5 mm cartridge Select Deselect

Catalog # 27880

Units
ea.  
Product Name
Revive ILSP holder for 5 mm cartridge  
27881 ea. Revive ILSP Pesticides cartridge (5 x 2.1 mm) Select Deselect

Catalog # 27881

Units
ea.  
Product Name
Revive ILSP Pesticides cartridge (5 x 2.1 mm)  
27882 kit Revive ILSP holder and Revive ILSP Pesticides cartridge (5 x 2.1 mm) Select Deselect

Catalog # 27882

Units
kit  
Product Name
Revive ILSP holder and Revive ILSP Pesticides cartridge (5 x 2.1 mm)  
27883 3-pk. Revive ILSP Pesticides cartridges (5 x 2.1 mm) Select Deselect

Catalog # 27883

Units
3-pk.  
Product Name
Revive ILSP Pesticides cartridges (5 x 2.1 mm)  

In-line sample preparation (ILSP) uses the power of an LC-MS/MS to streamline and automate sample extract cleanup. Restek’s Revive ILSP Pesticides cartridges are an ideal sample preparation alternative for food safety labs seeking to spend less time and money on multiresidue pesticides samples without sacrificing performance. Revive ILSP Pesticides cartridges separate analytes from potentially interfering matrix components just like conventional QuEChERS and SPE methods do, but they replace time-consuming manual procedures with a faster automated cleanup process that occurs on the instrument concurrently with sample analysis.

With a Revive ILSP Pesticides cartridge, six-port valve, and an independent isocratic pump, your instrument can be transformed into an analytical workhorse, combining sample cleanup and analysis in a single, efficient method. Significantly decrease sample preparation time, cut the costs associated with disposable sample prep products, and reduce errors related to manual procedures by integrating Revive ILSP into your current methods for multiresidue pesticides analysis in foods.