Welcome to the New Restek.com! Take a tour of the new site and feel free to send us your feedback.
Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.
Share:

Q-sep QuEChERS dSPE Tubes for Extract Cleanup

Fast, Simple Sample Prep for Multiresidue Pesticide Analysis

  • Packaged in foil subpacks of 10 for enhanced protection and storage stability.
  • Ready-to-use tubes, no glassware required.
  • Pre-weighed, ultra-pure sorbents.
  • Support original unbuffered, AOAC (2007.01), European (EN 15662), and mini-multiresidue QuEChERS methods.
Ordering Notes

Certificates of analysis for this product are provided electronically. To view and download your certificate, simply visit www.restek.com/documentation

Documentation and Instructions Sheets

Q-sep QuEChERS dSPE Tubes for Extract Cleanup

Catalog # 26215

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
26215 150 mg MgSO4, 25 mg PSA 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes Original unbuffered, EN 15662, mini-multiresidue General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon) Select Deselect

Catalog # 26215

Material
150 mg MgSO4, 25 mg PSA  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
Original unbuffered, EN 15662, mini-multiresidue  
Sample Type
General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon)  
Similar To
Agilent 5982-5021
26123 150 mg MgSO4, 50 mg PSA, 50 mg GCB 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes) Select Deselect

Catalog # 26123

Material
150 mg MgSO4, 50 mg PSA, 50 mg GCB  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes)  
26124 150 mg MgSO4, 50 mg PSA 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon) Select Deselect

Catalog # 26124

Material
150 mg MgSO4, 50 mg PSA  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon)  
26125 150 mg MgSO4, 50 mg PSA, 50 mg C18-EC 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy) Select Deselect

Catalog # 26125

Material
150 mg MgSO4, 50 mg PSA, 50 mg C18-EC  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy)  
26126 900 mg MgSO4, 300 mg PSA, 150 mg GCB 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries) Select Deselect

Catalog # 26126

Material
900 mg MgSO4, 300 mg PSA, 150 mg GCB  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
—  
Sample Type
Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries)  
26216 150 mg MgSO4, 25 mg PSA, 25 mg C18-EC 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes Mini-multiresidue Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy) Select Deselect

Catalog # 26216

Material
150 mg MgSO4, 25 mg PSA, 25 mg C18-EC  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
Mini-multiresidue  
Sample Type
Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy)  
Similar To
Agilent 5982-5121
26217 150 mg MgSO4, 25 mg PSA, 2.5 mg GCB 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes Mini-multiresidue, EN 15662 Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes) Select Deselect

Catalog # 26217

Material
150 mg MgSO4, 25 mg PSA, 2.5 mg GCB  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
Mini-multiresidue, EN 15662  
Sample Type
Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes)  
26218 150 mg MgSO4, 25 mg PSA, 7.5 mg GCB 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes Mini-multiresidue, EN 15662 Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries) Select Deselect

Catalog # 26218

Material
150 mg MgSO4, 25 mg PSA, 7.5 mg GCB  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
Mini-multiresidue, EN 15662  
Sample Type
Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries)  
26219 150 mg MgSO4, 50 mg PSA, 50 mg C18-EC, 50 mg GCB 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries) Select Deselect

Catalog # 26219

Material
150 mg MgSO4, 50 mg PSA, 50 mg C18-EC, 50 mg GCB  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries)  
26220 1200 mg MgSO4, 400 mg PSA 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon) Select Deselect

Catalog # 26220

Material
1200 mg MgSO4, 400 mg PSA  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon)  
26221 1200 mg MgSO4, 400 mg PSA, 400 mg C18-EC 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy) Select Deselect

Catalog # 26221

Material
1200 mg MgSO4, 400 mg PSA, 400 mg C18-EC  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy)  
Similar To
Agilent 5982-5158
26222 1200 mg MgSO4, 400 mg PSA, 400 mg C18-EC, 400 mg GCB 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes AOAC 2007.01 Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes) Select Deselect

Catalog # 26222

Material
1200 mg MgSO4, 400 mg PSA, 400 mg C18-EC, 400 mg GCB  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
AOAC 2007.01  
Sample Type
Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes)  
26223 900 mg MgSO4, 150 mg PSA 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes Original unbuffered, EN 15662 General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon) Select Deselect

Catalog # 26223

Material
900 mg MgSO4, 150 mg PSA  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
Original unbuffered, EN 15662  
Sample Type
General fruits and vegetables (e.g., celery, head lettuce, cucumber, melon)  
Similar To
Agilent 5982-5056
26224 900 mg MgSO4, 150 mg PSA, 15 mg GCB 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes EN 15662 Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes) Select Deselect

Catalog # 26224

Material
900 mg MgSO4, 150 mg PSA, 15 mg GCB  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
EN 15662  
Sample Type
Pigmented fruits and vegetables (e.g., strawberries, sweet potatoes, and tomatoes)  
26225 900 mg MgSO4, 150 mg PSA, 45 mg GCB 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes EN 15662 Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries) Select Deselect

Catalog # 26225

Material
900 mg MgSO4, 150 mg PSA, 45 mg GCB  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
EN 15662  
Sample Type
Highly pigmented fruits and vegetables (e.g., red peppers, spinach, blueberries)  
26226 900 mg MgSO4, 150 mg PSA, 150 mg C18-EC 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy) Select Deselect

Catalog # 26226

Material
900 mg MgSO4, 150 mg PSA, 150 mg C18-EC  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
—  
Sample Type
Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy)  
26242 150 mg MgSO4, 50 mg C18-EC 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy) Select Deselect

Catalog # 26242

Material
150 mg MgSO4, 50 mg C18-EC  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
—  
Sample Type
Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy)  
26243 150 mg MgSO4, 50 mg PSA, 50 mg C18-EC, 7.5 mg GCB 100-pk. 2 mL Q-sep QuEChERS dSPE Tubes General purpose (wide variety of sample types, including fatty and pigmented fruits and vegetables) Select Deselect

Catalog # 26243

Material
150 mg MgSO4, 50 mg PSA, 50 mg C18-EC, 7.5 mg GCB  
Type
2 mL Micro-Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (1 mL Extract)  
Units
100-pk.  
Volume
2 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
—  
Sample Type
General purpose (wide variety of sample types, including fatty and pigmented fruits and vegetables)  
26244 1200 mg MgSO4, 400 mg C18-EC 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy) Select Deselect

Catalog # 26244

Material
1200 mg MgSO4, 400 mg C18-EC  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
—  
Sample Type
Foodstuffs with fats and waxes (e.g., cereals, avocado, nuts, seeds, and dairy)  
26245 900 mg MgSO4, 300 mg PSA, 300 mg C18-EC, 45 mg GCB 50-pk. 15 mL Q-sep QuEChERS dSPE Tubes General purpose (wide variety of sample types, including fatty and pigmented fruits and vegetables) Select Deselect

Catalog # 26245

Material
900 mg MgSO4, 300 mg PSA, 300 mg C18-EC, 45 mg GCB  
Type
15 mL Centrifuge Tubes Prefilled with dSPE Materials for Cleanup (6 mL and 8 mL Extract)  
Units
50-pk.  
Volume
15 mL  
Product Name
Q-sep QuEChERS dSPE Tubes  
Method
—  
Sample Type
General purpose (wide variety of sample types, including fatty and pigmented fruits and vegetables)  

QuEChERS methods are fast, easy, and cost-effective, and Restek Q-sep products make QuEChERS procedures even simpler. All extraction salts, sorbents, and sample tubes are included—no specialized equipment or glassware is required. Prepare samples more efficiently with a complete line of QuEChERS supplies from Restek.

Multiple sorbents are used to extract different types of interferences.
MgSO4—removes excess water.
PSA (primary and secondary amine)—removes sugars, fatty acids, organic acids, and anthocyanine pigments.
C18-EC (end-capped)—removes nonpolar interferences.
GCB (graphitized carbon black)—removes pigments, sterols, and nonpolar interferences.

Note: No entry in the Method column refers to dSPE formulations not specifically included in one of the cited references. These products can be used to accommodate the various needs of specific matrices not directly met by the cited references.