Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul
  1. Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul

Restek

Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul

Katalognummer 36027
Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul

Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul

Überblick

Funktionen & Vorteile
  • Formulated for cannabis labs following Michigan or Missouri state-specific residual solvents methods.
  • High analyte concentrations allow for flexible calibration curves.
  • Our proprietary manufacturing process was optimized to ensure standards are accurate, reproducible, and stable.
  • Second independent lots available to ensure you can meet your requirements without needing to source another supplier.
  • Verified composition and stability.
Beschreibung
Compound CAS Concentration
Benzene 71-43-2 500 µg/mL
1,2-Dichloroethane 107-06-2 500 µg/mL
Chloroform 67-66-3 500 µg/mL
Trichloroethylene (1,1,2-Trichloroethylene) 79-01-6 500 µg/mL
n-Hexane 110-54-3 5000 µg/mL
2-methylpentane 107-83-5 5000 µg/mL
3-methylpentane 96-14-0 5000 µg/mL
2,2-dimethylbutane 75-83-2 5000 µg/mL
2,3-dimethylbutane 79-29-8 5000 µg/mL
Acetonitrile 75-05-8 5000 µg/mL
Dichloromethane (Methylene chloride) 75-09-2 5000 µg/mL
Toluene 108-88-3 5000 µg/mL
1,2-dimethylbenzene (ortho-) 95-47-6 5000 µg/mL
1,3-dimethylbenzene (meta-) 108-38-3 5000 µg/mL
1,4-dimethylbenzene (para-) 106-43-3 5000 µg/mL
Methanol (Methyl Alcohol) 67-56-1 5000 µg/mL
Ethyl Acetate (Acetic Acid Ethyl Ester) 141-78-6 5000 µg/mL
Heptane (n-Heptane) 142-82-5 5000 µg/mL
Isopropyl Alcohol (2-Propanol, Isopropanol, IPA) 67-63-0 5000 µg/mL
Ethyl Ether (Diethyl Ether, 1,1'-Oxybisethane) 60-29-7 5000 µg/mL
Acetone 67-64-1 5000 µg/mL
n-Pentane 109-66-0 5000 µg/mL
iso-Pentane 78-78-4 5000 µg/mL
Ethanol (Ethyl Alcohol) 64-17-5 5000 µg/mL

Spezifikationen

Produktspezifikationen
Katalognummer
36027
Produktname
Michigan/Missouri Residual Solvents Standard, 500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul