![Restek](/file/general/restek-logo.png)
![Restek](/file/general/restek-logo.png)
![Kit di standard per l’analisi multiresiduale LC dei pesticidi Kit di standard per l’analisi multiresiduale LC dei pesticidi](/ccstore/v1/images/?source=/file/v7018015082888859837/products/31971.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
![Kit di standard per l’analisi multiresiduale LC dei pesticidi Kit di standard per l’analisi multiresiduale LC dei pesticidi](/ccstore/v1/images/?source=/file/v6460347190350358431/products/31971_v2.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
![Kit di standard per l’analisi multiresiduale LC dei pesticidi Kit di standard per l’analisi multiresiduale LC dei pesticidi](/ccstore/v1/images/?source=/file/v9078904579779751542/products/31971_v3.jpg&height=475&width=475&quality=0.8&outputFormat=JPEG)
Kit di standard per l’analisi multiresiduale LC dei pesticidi
![Kit di standard per l’analisi multiresiduale LC dei pesticidi](/ccstore/v1/images/?source=/file/v7018015082888859837/products/31971.jpg&height=200&width=200)
Kit di standard per l’analisi multiresiduale LC dei pesticidi
Panoramica
- Rileva e quantifica con precisione i pesticidi di interesse globale per la sicurezza alimentare in una vasta gamma di frutta, verdura e altri prodotti con il sistema LC-MS/MS.
- Il kit completo contiene 204 composti di interesse e copre molti pesticidi determinati mediante analisi LC, presenti nelle liste delle agenzie governative; le ampolle singole sono vendute anche separatamente.
- I composti sono formulati e raggruppati per garantire la massima stabilità a lungo termine.
- Il kit è sottoposto a test quantitativi per confermare la composizione (dettagliata documentazione di supporto acclusa).
- Il metodo ottimizzato per l’analisi di pesticidi multiresiduali è offerto gratuitamente; il file XLS scaricabile include le condizioni e le tabelle di transizione.
- Restek è il tuo fornitore globale per la migliore analisi multiresiduale LC-MS/MS dei pesticidi: standard interni e di riferimento, colonne LC, prodotti per la preparazione dei campioni Q-sep QuEChERS, accessori e molto altro!
* Nota: Quando si combinano numerosi composti con funzionalità chimiche diverse, la stabilità della miscela può diventare un problema. Nel formulare questi standard abbiamo studiato approfonditamente i 204 composti presi in esame e li abbiamo poi raggruppati nel minor numero di miscele possibile, pur garantendo la massima stabilità e affidabilità a lungo termine. Per le analisi quantitative consigliamo di analizzare separatamente ogni miscela per ottenere risultati precisi per ciascun composto.
Contiene una ampolla di ogni componente qui di seguito elencato.
31972: Standard di pesticidi per analisi multiresiduale LC n 1
composti organofosforici
100 µg/mL, acetonitrile, 1 mL/ampolla
Acephate (30560-19-1)
Carbaryl (Sevin) (63-25-2)
Dicrotophos (141-66-2)
Dimethoate (60-51-5)
Dimethomorph (110488-70-5)
Isocarbophos (24353-61-5)
Methamidophos (10265-92-6)
Mevinphos (7786-34-7)
Monocrotophos (6923-22-4)
Omethoate (1113-02-6)
Temephos (Abate) (3383-96-8)
Trichlorfon (Dylox) (52-68-6)
Vamidothion (Vamidoate) (2275-23-2)
31973: Standard di pesticidi per analisi multiresiduale LC n 2
composti carbammati/uronici
100 µg/mL, acetonitrile, 1 mL/ampolla
Alanycarb (83130-01-2)
Aldicarb (116-06-3)
Aldicarb sulfone (1646-88-4)
Aldicarb sulfoxide (1646-87-3)
Benfuracarb (82560-54-1)
Butocarboxim (34681-10-2)
Butoxycarboxim (34681-23-7)
Ethiofencarb (29973-13-5)
Furathiocarb (65907-30-4)
Methabenzthiazuron (18691-97-9)
Methiocarb (2032-65-7)
Methomyl (16752-77-5)
Oxamyl (23135-22-0)
Tebuthiuron (34014-18-1)
Thidiazuron (51707-55-2)
Thiophanate-methyl (23564-05-8)
31974: Standard di pesticidi per analisi multiresiduale LC n 3
composti carbammati/uronici
100 µg/mL, acetonitrile, 1 mL/ampolla
Bendiocarb (22781-23-3)
Bifenazate (149877-41-8)
Carbofuran (1563-66-2)
Chlorfluazuron (71422-67-8)
Chloroxuron (1982-47-4)
Chlortoluron (15545-48-9)
Cycluron (2163-69-1)
Diethofencarb (87130-20-9)
Diflubenzuron (35367-38-5)
Dioxacarb (6988-21-2)
Diuron (330-54-1)
Fenobucarb (BPMC) (3766-81-2)
Fenoxycarb (72490-01-8)
Fenuron (101-42-8)
Flufenoxuron (101463-69-8)
Fluometuron (2164-17-2)
Forchlorfenuron (68157-60-8)
Hexaflumuron (86479-06-3)
3-Hydroxycarbofuran (16655-82-6)
Indoxacarb (173584-44-6)
Iprovalicarb (140923-17-7)
Isoprocarb (2631-40-5)
Isoproturon (34123-59-6)
Linuron (330-55-2)
Lufenuron (103055-07-8)
Metobromuron (3060-89-7)
Monolinuron (1746-81-2)
Neburon (555-37-3)
Novaluron (116714-46-6)
Pirimicarb (23103-98-2)
Promecarb (2631-37-0)
Propham (122-42-9)
Propoxur (Baygon) (114-26-1)
Pyraclostrobin (175013-18-0)
Siduron (1982-49-6)
Teflubenzuron (83121-18-0)
Thiobencarb (28249-77-6)
Triflumuron (64628-44-0)
31975: Standard di pesticidi per analisi multiresiduale LC n 4
composti organici azotati
100 g/mL, acetonitrile, 1 mL/ampolla
Abamectin (71751-41-2)
Acetamiprid (135410-20-7)
Ametryn (834-12-8)
Amitraz (33089-61-1)
Azoxystrobin (131860-33-8)
Benalaxyl (71626-11-4)
Benzoximate (29104-30-1)
Boscalid (188425-85-6)
Butafenacil (134605-64-4)
Carbetamide (16118-49-3)
Carfentrazone ethyl (128639-02-1)
Chlorantraniliprole (500008-45-7)
Clofentezine (74115-24-5)
Cymoxanil (57966-95-7)
Cyprodinil (121552-61-2)
Cyromazine (66215-27-8)
Dimoxystrobin (149961-52-4)
Dinotefuran (165252-70-0)
Doramectin (117704-25-3)
Eprinomectin (123997-26-2)
Famoxadon (131807-57-3)
Fenazaquin (120928-09-8)
Fenhexamid (126833-17-8)
(E)-Fenpyroximate (134098-61-6)
Flonicamid (158062-67-0)
Fluazinam (79622-59-6)*
Fludioxonil (131341-86-1)
Fluoxastrobin (361377-29-9)
Flutolanil (66332-96-5)
Furalaxyl (57646-30-7)
Halofenozide (112226-61-6)
Imazalil (35554-44-0)
Imidacloprid (138261-41-3)
Ivermectin (70288-86-7)
Kresoxim methyl (143390-89-0)
Mandipropamid (374726-62-2)
Mepanipyrim (110235-47-7)
Mepronil (55814-41-0)
Metaflumizone (139968-49-3)
Metalaxyl (57837-19-1)
Methoxyfenozide (161050-58-4)
Moxidectin (113507-06-5)
Myclobutanil (88671-89-0)
Nitenpyram (120738-89-8)
Oxadixyl (77732-09-3)
Picoxystrobin (117428-22-5)
Piperonyl butoxide (51-03-6)
Prochloraz (67747-09-5)
Prometon (1610-18-0)
Pymetrozine (123312-89-0)
Pyracarbolid (24691-76-7)
Pyrimethanil (53112-28-0)
Pyriproxyfen (95737-68-1)
Quinoxyfen (124495-18-7)
Rotenone (83-79-4)
Secbumeton (26259-45-0)
Spiroxamine (118134-30-8)
Tebufenozide (112410-23-8)
Tebufenpyrad (119168-77-3)
Terbumeton (33693-04-8)
Triadimefon (43121-43-3)
Trifloxystrobin (141517-21-7)
Zoxamide (156052-68-5)
31976: Standard di pesticidi per analisi multiresiduale LC n 5
composti organici azotati
100 g/mL, acetonitrile, 1 mL/ampolla
Acibenzolar-S-methyl (135158-54-2)
Bupirimate (41483-43-6)
Buprofezin (69327-76-0)
Carboxin (5234-68-4)
Clethodim (99129-21-2)
Clothianidin (210880-92-5)
Cyazofamid (120116-88-3)
Ethiprole (181587-01-9)
Ethofumesate (26225-79-6)
Fenamidone (161326-34-7)
Fipronil (120068-37-3)
Flubendiamide (272451-65-7)
Flufenacet (Fluthiamide) (142459-58-3)
Hexythiazox (78587-05-0)
Mefenacet (73250-68-7)
Mesotrione (104206-82-8)
Methoprotryne (841-06-5)
Metribuzin (21087-64-9)
Prometryne (7287-19-6)
Propargite (2312-35-8)
Prothioconazole (178928-70-6)
Pyridaben (96489-71-3)
Simetryn (1014-70-6)
Sulfentrazone (122836-35-5)
Terbutryn (886-50-0)
Thiabendazole (148-79-8)
Thiacloprid (111988-49-9)
Thiamethoxam (153719-23-4)
Thiofanox (39196-18-4)
Tricyclazole (Beam) (41814-78-2)
31977: Standard di pesticidi per analisi multiresiduale LC n 6
composti organici azotati
100 g/mL, acetonitrile, 1 mL/ampolla
Baycor (Bitertanol) (55179-31-2)
Bromuconazole (116255-48-2)
Cyproconazole (94361-06-5)
Diclobutrazol (75736-33-3)
Difenoconazole (119446-68-3)
Diniconazole (83657-24-3)
Epoxiconazole (133855-98-8)
Etaconazole (60207-93-4)
Ethirimol (23947-60-6)
Etoxazole (153233-91-1)
Fenarimol (60168-88-9)
Fenbuconazole (114369-43-6)
Fluquinconazole (136426-54-5)
Flusilazole (85509-19-9)
Flutriafol (76674-21-0)
Fuberidazole (3878-19-1)
Hexaconazole (79983-71-4)
Ipconazole (125225-28-7)
Metconazole (125116-23-6)
Nuarimol (63284-71-9)
Paclobutrazol (76738-62-0)
Penconazole (66246-88-6)
Propiconazole (Tilt) (60207-90-1)
Tebuconazole (107534-96-3)
Tetraconazole (112281-77-3)
Triadimenol (55219-65-3)
Triflumizole (68694-11-1)
Triticonazole (131983-72-7)
31978: Standard di pesticidi per analisi multiresiduale LC n 7
composti organici azotati
100 g/mL, acetonitrile, 1 mL/ampolla
Emamectin-benzoate (155569-91-8)
Fenpropimorph (67564-91-4)
Spinetoram (J&L) (935545-74-7)**
Spinosad (A&D) (168316-95-8)†
Spirodiclofen (148477-71-8)
Spiromesifen (283594-90-1)
Spirotetramat (203313-25-1)
31979: Standard di pesticidi per analisi multiresiduale LC n° 8 (idrametilnone)
composti organici azotati
100 µg/mL, acetronitrile, 1mL/ampolla
Hydramethylnon (67485-29-4)
31980: Standard di pesticidi per analisi multiresiduale LC n 9
composti carbammati/uronici
100 µg/mL, acetonitrile, 1 mL/ampolla
Aminocarb (2032-59-9)
Desmedipham (13684-56-5)
Formetanate HCL (23422-53-9)
Mexacarbate (Zectran) (315-18-4)
Monceren (Pencycuron) (66063-05-6)
Phenmedipham (13684-63-4)
Propamocarb free base (24579-73-5)
31981: Standard di pesticidi per analisi multiresiduale LC n° 10 (carbendazim)
composti carbammati/uronici
100 µg/mL, metanolo 1 mL/ampolla
Carbendazim (10605-21-7)
* In questo standard, utilizzare il fluazinam solo per le analisi qualitative.
**Questo materiale di riferimento contiene sia l'isomero Spinetoram J che l'isomero L (187166-40-1 e 187166-15-0);Tuttavia, il n° CAS 935545-74-7 è riportato sul certificato in quanto si tratta del materiale puro disciolto nella soluzione. Il n° CAS 935545-74-7 è una miscela di Spinetoram J e L, e il rapporto di ciascun isomero del materiale è riportato sul certificato di analisi.
†Questo materiale di riferimento contiene gli isomeri di Spinosad A e D (131929-60-7 e 131929-63-0); tuttavia, il numero CAS 168316-95-8 è riportato sul certificato in quanto si tratta del materiale puro disciolto nella soluzione. Il numero CAS 168316-95-8 è una miscela di Spinosad A e D e il rapporto di ciascun isomero del materiale è indicato nel certificato di analisi.