Restek
ホーム / ガスクロマトグラフィー / ガス精製&発生装置 / ガスフィルタキット / Click-On インラインフィルタ / Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass
Restek
Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass
  1. Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass

Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass

カタログ番号 22470
Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass

Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass

概要

特徴&利点
  • High-purity output ensures 99.9999% pure gas.
  • Click-On fittings for easy, leak-tight cartridge changes; brass or stainless steel, 1/4" or 1/8".
  • Triple gas trap is ideal for purifying carrier gas—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
  • Fuel gas trap is ideal for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons.
  • Helium-specific triple gas trap is ideal for GC-MS—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
製品詳細

Specifications for Click-On Inline Super-Clean Purification Gas Traps

Click-On Traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2 cm)

-----Capacity------
Type of Filter Gas Quality
at Outlet
Maximum Pressure Maximum Flow
(L/min.)
Use for: H20 (g) O2 (mL) Hydrocarbons (g)
(as n-butane)
Estimated Lifetime
(years)
Moisture
cat.# 22467
>99.9999 11 bar
160 psi
25 Inert carrier gas
Helium
Air
Hydrogen
15 NA NA >3
Oxygen
cat.# 22468
>99.9999 11 bar
160 psi
25 Inert carrier gas
Hydrogen
NA 2000 NA >3
Hydrocarbon
cat.# 22466
>99.9999 11 bar
160 psi
25 Inert carrier gas
Helium
Air
Hydrogen
NA NA 24 >3
Fuel Gas1
cat.# 22465
>99.9999 11 bar
160 psi
25 Inert carrier gas
Helium
Air
Hydrogen
7 NA 12 >2
Triple2
cat.# 22464
>99.9999 11 bar
160 psi
25 Inert carrier gas
Hydrogen
4 1000 8 >2
Helium-Specific Triple2
cat.# 22473
>99.9999 11 bar
160 psi
25 Helium 4 1000 8 >2

1 Removes hydrocarbons, moisture.
2 Removes hydrocarbons, moisture, oxygen.

Note:
Super-Clean Gas Filters are recommended for purifying noncorrosive gases with low concentrations of contaminants. The maximum concentration of oxygen in the incoming gas stream for oxygen purifiers is 0.5%.

Did you know?
Trap replacement depends on the quality of the incoming gas. Use the double connector and install an indicating cartridge after a trap to indicate when the trap should be replaced.

To prevent settling of desiccant, mount vertically, not horizontally.

仕様

製品仕様
カタログ番号
22470
製品名
Click-On In-Line Super Clean Helium-Specific Carrier Gas Cleaning Kit, 1/8" Brass