Rocker 300 Vacuum Pump, 21 L/min, AC110 V, 60 Hz
Rocker 300 Vacuum Pump, 21 L/min, AC110 V, 60 Hz
概要
- Oil-free vacuum pumps are piston powered, so they do not pollute the air and require minimal maintenance.
- Quiet, low-vibration units keep disturbances to a minimum.
- Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the unit is cool.
- Inlet filter traps particles and removes moisture, prolonging pump life.
- International CE and CSA certification.
- Applications include filtration for air sampling, microbiology, suspended solid test, vacuum oven, thermal desorption (TD) tubes, sampling bags (regulator recommended for TD tubes and sampling bags), and general use. (Not intended to evacuate air canisters.)
- Two-year pump warranty.
Specifications for Rocker Vacuum Pumps
Model |
Rocker 300 |
Rocker 300DC |
Rocker 400 |
Rocker 410 |
Rocker 500 |
Rocker 600 |
Rocker 610 |
||||||
Voltage |
110 V, 60 Hz |
220 V, 50 Hz |
DC |
110 V, 60 Hz |
220 V, 50 Hz |
110 V, 60 Hz |
220 V, 50 Hz |
110 V, 60 Hz |
220 V, 50 Hz |
110 V, 60 Hz |
220 V, 50 Hz |
110 V, 60 Hz |
220 V, 50 Hz |
Max. power (W) |
65 |
60 |
35 |
100 |
80 |
100 |
80 |
100 |
100 |
190 |
180 |
190 |
180 |
Max. current (A) |
0.7 |
0.3 |
3 |
1.0 |
0.4 |
1.0 |
0.4 |
0.8 |
0.5 |
1.7 |
1 |
1.7 |
1 |
Max. vacuum |
-670 mm Hg |
-650 mm Hg |
-670 mm Hg |
-730 mm Hg |
-650 mm Hg |
-650 mm Hg |
-730 mm Hg |
||||||
Max. flow rate |
21 L/min |
18 L/min |
25 L/min |
37 L/min |
34 L/min |
23 L/min |
20 L/min |
28 L/min |
23 L/min |
65 L/min |
62 L/min |
41 L/min |
36 L/min |
Moisture trap / vacuum regulator |
Yes |
Yes |
Yes |
Yes |
- |
- |
Yes |
Yes |
|||||
Overflow protection |
Yes |
Yes |
Yes |
Yes |
- |
- |
Yes |
Yes |
|||||
Motor rotation |
1700 rpm |
1450 rpm |
1800 rpm |
1750 rpm |
1450 rpm |
1750 rpm |
1450 rpm |
3200 rpm |
3000 rpm |
1700 rpm |
1450 rpm |
1700 rpm |
1450 rpm |
Horsepower |
1/8 HP |
1/8 HP |
1/6 HP |
1/6 HP |
1/8 HP |
1/4 HP |
1/4 HP |
||||||
Noise level |
50 dB |
50 dB |
52 dB |
52 dB |
60 dB |
62 dB |
62 dB |
||||||
Port thread |
5/16 inch |
5/16 inch |
5/16 inch |
5/16 inch |
5/16 inch |
5/16 inch |
5/16 inch |
||||||
Net weight |
4.1 kg |
3.5 kg |
5.2 kg |
5.2 kg |
4.1 kg |
7.6 kg |
7.6 kg |
||||||
Dimensions |
27.2 x |
27.2 x |
29.8 x |
29.8 x |
29.8 x |
- |
34.1 x |
34.1 x |