SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
Also available: SVOC MegaMix 100 kit (cat.# 31908) contains 100 of the most frequently analyzed semivolatiles (does not contain Appendix IX mixes or methapyrilene).
U.S. DEA-exempted formulation—no additional customer permits or licensing are required to purchase within the U.S.

SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
概要
- Streamline operations: kit contains 150 of the most frequently analyzed semivolatiles.
- Designed to make it easy to construct a 200 µg/mL working standard, allowing for wider calibration ranges, and reducing the need for sample dilution.
- Formulated for greater stability to ensure more accurate data.
- Available in two independently manufactured lots with verified lot-to-lot agreement, reducing uncertainty and improving quality.
このキットには、以下のものが各1アンプル入っています。
Cat.# 31850: 8270 MegaMix1000 µg/mL each in methylene chloride (3-methylphenol and 4-methylphenol at 500 µg/mL), 1 mL/ampul
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Aniline (62-53-3)
Anthracene (120-12-7)
Azobenzene (103-33-3)*
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl alcohol (100-51-6)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)adipate (103-23-1)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
Carbazole (86-74-8)
4-Chloroaniline (106-47-8)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Dibenzofuran (132-64-9)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
1,2-Dinitrobenzene (528-29-0)
1,3-Dinitrobenzene (99-65-0)
1,4-Dinitrobenzene (100-25-4)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)†
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
Naphthalene (91-20-3)
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
Pyridine (110-86-1)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,3,5,6-Tetrachlorophenol (935-95-5)
1,2,4-Trichlorobenzene (120-82-1)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)
Cat.# 31909: SVOC Additions
1000 µg/mL each in methylene chloride, 1 mL/ampul
Acrylamide (79-06-1)
Benzidine (92-87-5)
n-Decane (C10) (124-18-5)
Dibenz(a,h)acridine (226-36-8)
2,3-Dichloroaniline (608-27-5)
3,3'-Dichlorobenzidine (91-94-1)
Dimethoate (60-51-5)
Dinoseb (88-85-7)
Disulfoton (298-04-4)
Famphur (52-85-7)
n-Hexadecane (C16) (544-76-3)
Indene (95-13-6)
Methyl parathion (298-00-0)
6-Methylchrysene (1705-85-7)
4,4'-Methylene-bis(2-chloroaniline) (101-14-4)
n-Octadecane (C18) (593-45-3)
Parathion (ethyl parathion) (56-38-2)
Phorate (298-02-2)
Quinoline (91-22-5)
Sulfotepp (3689-24-5)
α-Terpineol (98-55-5)
o,o,o-Triethyl phosphorothioate (126-68-1)
Zalophus (thionazine) (297-97-2)
Cat.# 32459: Appendix IX mix #1, revised
2000 µg/mL each in methylene chloride, 1 mL/ampul
2-Acetylaminofluorene (53-96-3)
4-Aminobiphenyl (92-67-1)
p-Dimethylaminoazobenzene (60-11-7)
3,3'-Dimethylbenzidine (o-tolidine) (119-93-7)
α,α-Dimethylphenethylamine (phentermine) (122-09-8)
1-Naphthylamine (1-aminonaphthalene) (134-32-7)
2-Naphthylamine (2-aminonaphthalene) (91-59-8)
N-Nitrosodibutylamine (924-16-3)
N-Nitrosodiethylamine (55-18-5)
N-Nitrosomethylethylamine (10595-95-6)
N-Nitrosomorpholine (59-89-2)
N-Nitrosopiperidine (100-75-4)
N-Nitrosopyrrolidine (930-55-2)
5-Nitro-o-toluidine (99-55-8)
1,4-Phenylenediamine (106-50-3)
2-Picoline (109-06-8)
o-Toluidine (95-53-4)
Cat.# 32460: Methapyrilene
2000 µg/mL in methylene chloride, 1 mL/ampul
Methapyrilene hydrochloride (135-23-9)
Cat.# 31806: Appendix IX mix #2
1000 µg/mL each in methylene chloride, 1 mL/ampul
Acetophenone (98-86-2)
Aramite (140-57-8)
Atrazine (1912-24-9)
Benzaldehyde (100-52-7)
Biphenyl (92-52-4)
ε-Caprolactam (105-60-2)
Chlorobenzilate (510-15-6)
1-Chloronaphthalene (90-13-1)
Diallate (2303-16-4)
Dibenz[a,j]acridine (224-42-0)
2,6-Dichlorophenol (87-65-0)
7,12-Dimethylbenz[a]anthracene (57-97-6)
1,4-Dioxane (123-91-1)
Diphenyl ether (101-84-8)
Ethyl methacrylate (97-63-2)
Ethyl methanesulfonate (62-50-0)
Hexachloropropene (1888-71-7)
Isodrin (465-73-6)
Isosafrole (cis & trans) (120-58-1)
Kepone (143-50-0)
3-Methylcholanthrene (56-49-5)
Methyl methanesulfonate (66-27-3)
1,4-Naphthoquinone (130-15-4)
4-Nitroquinoline-N-oxide (56-57-5)
Pentachlorobenzene (608-93-5)
Pentachloroethane (76-01-7)
Pentachloronitrobenzene (Quintozene) (82-68-8)
Phenacetin (62-44-2)
Propyzamide (23950-58-5)
Safrole (94-59-7)
1,2,4,5-Tetrachlorobenzene (95-94-3)
1,3,5-Trinitrobenzene (99-35-4)
Cat.# 31879: Benzoic acid
2000 µg/mL in methylene chloride, 1 mL/ampul
Benzoic acid (65-85-0)
*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.