508.1 Pesticides Kit
カタログ番号 32097

508.1 Pesticides Kit
概要
特徴&利点
Contains 1 mL each of these mixtures.
32045: 508 Performance Check Mix
32091: 508.1 Internal Standard Mix
32092: 508.1 Surrogate Mix
32093: 508.1 GC Degradation Check Mix
32094: 508.1 Calibration Mix #1
32095: 508.1 Calibration Mix #2
32096: 508.1 Calibration Mix #3
32045: 508 Performance Check Mix
32091: 508.1 Internal Standard Mix
32092: 508.1 Surrogate Mix
32093: 508.1 GC Degradation Check Mix
32094: 508.1 Calibration Mix #1
32095: 508.1 Calibration Mix #2
32096: 508.1 Calibration Mix #3
製品詳細
Contains 1 mL each of these mixtures.
32045: 508 Performance Check Mix
δ-BHC (319-86-8), 0.4 µg/mL
Chlorothalonil (1897-45-6), 0.5 µg/mL
Chlorpyrifos (2921-88-2), 0.02 µg/mL
DCPA methyl ester (Chlorthal-dimethyl) (1861-32-1), 0.5 µg/mL
32091: 508.1 Internal Standard
Pentachloronitrobenzene (82-68-8)
32092: 508.1 Surrogate
4,4'-Dibromobiphenyl (92-86-4)
32093: 508.1 GC Degradation Check Mix
4,4'-DDT (50-29-3)
Endrin (72-20-8)
32094: 508.1 Calibration Mix #1
Aldrin (309-00-2)
α-BHC (319-84-6)
β-BHC (319-85-7)
γ-BHC (Lindane) (58-89-9)
δ-BHC (319-86-8)
4,4'-DDD (72-54-8)
4,4'-DDE (72-55-9)
4,4'-DDT (50-29-3)
Dieldrin (60-57-1)
Endosulfan I (959-98-8)
Endosulfan II (33213-65-9)
Endosulfan sulfate (1031-07-8)
Endrin (72-20-8)
Endrin aldehyde (7421-93-4)
Heptachlor (76-44-8)
Heptachlor epoxide (isomer B) (1024-57-3)
Methoxychlor (72-43-5)
32095: 508.1 Calibration Mix #2
Chlorobenzilate (510-15-6)
cis-Chlordane (5103-71-9)
trans-Chlordane (5103-74-2)
Chloroneb (2675-77-6)
DCPA methyl ester (Chlorthal-dimethyl) (1861-32-1)
Etridiazole (2593-15-9)
Hexachlorobenzene (118-74-1)
cis-Permethrin* (52645-53-1)
trans-Permethrin* (52645-53-1)
Propachlor (1918-16-7)
Trifluralin (1582-09-8)
32096: 508.1 Calibration Mix #3
Alachlor (15972-60-8)
Atrazine (1912-24-9)
Chlorothalonil (1897-45-6)
Cyanazine (Bladex) (21725-46-2)
Hexachlorocyclopentadiene (77-47-4)
Metolachlor (51218-45-2)
Metribuzin (21087-64-9)
Simazine (122-34-9)
32045: 508 Performance Check Mix
δ-BHC (319-86-8), 0.4 µg/mL
Chlorothalonil (1897-45-6), 0.5 µg/mL
Chlorpyrifos (2921-88-2), 0.02 µg/mL
DCPA methyl ester (Chlorthal-dimethyl) (1861-32-1), 0.5 µg/mL
32091: 508.1 Internal Standard
Pentachloronitrobenzene (82-68-8)
32092: 508.1 Surrogate
4,4'-Dibromobiphenyl (92-86-4)
32093: 508.1 GC Degradation Check Mix
4,4'-DDT (50-29-3)
Endrin (72-20-8)
32094: 508.1 Calibration Mix #1
Aldrin (309-00-2)
α-BHC (319-84-6)
β-BHC (319-85-7)
γ-BHC (Lindane) (58-89-9)
δ-BHC (319-86-8)
4,4'-DDD (72-54-8)
4,4'-DDE (72-55-9)
4,4'-DDT (50-29-3)
Dieldrin (60-57-1)
Endosulfan I (959-98-8)
Endosulfan II (33213-65-9)
Endosulfan sulfate (1031-07-8)
Endrin (72-20-8)
Endrin aldehyde (7421-93-4)
Heptachlor (76-44-8)
Heptachlor epoxide (isomer B) (1024-57-3)
Methoxychlor (72-43-5)
32095: 508.1 Calibration Mix #2
Chlorobenzilate (510-15-6)
cis-Chlordane (5103-71-9)
trans-Chlordane (5103-74-2)
Chloroneb (2675-77-6)
DCPA methyl ester (Chlorthal-dimethyl) (1861-32-1)
Etridiazole (2593-15-9)
Hexachlorobenzene (118-74-1)
cis-Permethrin* (52645-53-1)
trans-Permethrin* (52645-53-1)
Propachlor (1918-16-7)
Trifluralin (1582-09-8)
32096: 508.1 Calibration Mix #3
Alachlor (15972-60-8)
Atrazine (1912-24-9)
Chlorothalonil (1897-45-6)
Cyanazine (Bladex) (21725-46-2)
Hexachlorocyclopentadiene (77-47-4)
Metolachlor (51218-45-2)
Metribuzin (21087-64-9)
Simazine (122-34-9)
仕様
製品仕様
カタログ番号
32097
製品名
508.1 Pesticides Kit