Restek
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
概要
- 58-component kit provides analytical flexibility for constructing calibration curves or spiking sample matrices—saving time and reducing cost.
- The standard concentration of each mix is 400 times the action limit—100 times when all four mixes are combined.
- Two independently produced lots available.
- Verified composition and stability ensures long-lasting shelf life.
- Formulated for Arizona cannabis regulations; can be used to meet other government or in-house method requirements.
このキットには、以下のものが各1アンプル入っています。 1 mL/ampul
Cat.# 32601: Arizona Pesticide Standard #1
化合物 | CAS# | Concentration |
---|---|---|
Acephate | 30560-19-1 | 160 µg/mL |
Aldicarb | 116-06-3 | 160 µg/mL |
Bifenazate | 149877-41-8 | 80 µg/mL |
Carbaryl (Sevin) | 63-25-2 | 80 µg/mL |
Carbofuran | 1563-66-2 | 80 µg/mL |
Chlorpyrifos | 2921-88-2 | 80 µg/mL |
Dichlorvos | 62-73-7 | 40 µg/mL |
Diazinon | 333-41-5 | 80 µg/mL |
Dimethoate | 60-51-5 | 80 µg/mL |
Ethoprophos | 13194-48-4 | 80 µg/mL |
Fenoxycarb | 72490-01-8 | 80 µg/mL |
Malathion | 121-75-5 | 80 µg/mL |
Methiocarb | 2032-65-7 | 80 µg/mL |
Methomyl | 16752-77-5 | 160 µg/mL |
Naled | 300-76-5 | 200 µg/mL |
Oxamyl | 23135-22-0 | 400 µg/mL |
Phosmet | 732-11-6 | 80 µg/mL |
Propoxur | 114-26-1 | 80 µg/mL |
Cat.# 32602: Arizona Pesticide Standard #2
化合物 | CAS# | Concentration |
---|---|---|
Abamectin | 71751-41-2 | 200 µg/mL |
Acequinocyl | 57960-19-7 | 800 µg/mL |
Bifenthrin | 82657-04-3 | 80 µg/mL |
Cyfluthrin | 68359-37-5 | 400 µg/mL |
Cypermethrin | 52315-07-8 | 400 µg/mL |
Etofenprox | 80844-07-1 | 160 µg/mL |
Permethrin (cis & trans) | 52645-53-1 | 80 µg/mL |
Prallethrin | 23031-36-9 | 80 µg/mL |
Pyrethrins* | 8003-34-7 | 400 µg/mL |
Spinosad (A&D)† | 168316-95-8 | 80 µg/mL |
Cat.# 32603: Arizona Pesticide Standard #3
化合物 | CAS# | Concentration |
---|---|---|
Acetamiprid | 135410-20-7 | 80 µg/mL |
Clofentezine | 74115-24-5 | 80 µg/mL |
Etoxazole | 153233-91-1 | 80 µg/mL |
Fipronil | 120068-37-3 | 160 µg/mL |
Fludioxonil | 131341-86-1 | 160 µg/mL |
Imazalil | 35554-44-0 | 80 µg/mL |
Imidacloprid | 138261-41-3 | 160 µg/mL |
Myclobutanil | 88671-89-0 | 80 µg/mL |
Paclobutrazol | 76738-62-0 | 160 µg/mL |
Pendimethalin | 40487-42-1 | 40 µg/mL |
Propiconazole (Tilt) | 60207-90-1 | 160 µg/mL |
Tebuconazole | 107534-96-3 | 160 µg/mL |
Thiacloprid | 111988-49-9 | 80 µg/mL |
Thiamethoxam | 153719-23-4 | 80 µg/mL |
Cat.# 32604: Arizona Pesticide Standard #4
化合物 | CAS# | Concentration |
---|---|---|
Azoxystrobin | 131860-33-8 | 80 µg/mL |
Boscalid | 188425-85-6 | 160 µg/mL |
Chlorantraniliprole‡ | 500008-45-7 | 80 µg/mL |
Chlorfenapyr | 122453-73-0 | 400 µg/mL |
Daminozide‡ | 1596-84-5 | 400 µg/mL |
(E)-Fenpyroximate | 134098-61-6 | 160 µg/mL |
Flonicamid | 158062-67-0 | 400 µg/mL |
Hexythiazox | 78587-05-0 | 400 µg/mL |
Kresoxim methyl | 143390-89-0 | 160 µg/mL |
Metalaxyl | 57837-19-1 | 80 µg/mL |
Piperonyl butoxide | 51-03-6 | 800 µg/mL |
Pyridaben | 96489-71-3 | 80 µg/mL |
Spiromesifen | 283594-90-1 | 80 µg/mL |
Spirotetramat | 203313-25-1 | 80 µg/mL |
Spiroxamine | 118134-30-8 | 160 µg/mL |
Trifloxystrobin | 141517-21-7 | 80 µg/mL |
*Pyrethrinsは、6 つの活性殺虫性化合物よりなるTechnical Mixtureとなります。各化合物の比率は、証明書に記載された分析条件での溶出順に応じて記載されており、クロマトグラム上ではもっとも信号強度が高いPyrethrin化合物のピークだけがラベル付けされています。Pyrethrinsの性質により、原料に依存してロット間での組成と純度のばらつきが観察されることがあります。
†This reference material contains スピノサド A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of スピノサド A and D, and the ratio of each material isomer are displayed on your certificate of analysis.
‡クロルアントラニリプロール (500008-45-7) およびダミノジット (1596-84-5) を含む標準物質は、アンプル開封前に最低60分の超音波処理を行ってください。60分は目安となります。超音波処理時間の延長は製品品質に影響しませんので、ご使用の超音波バスの出力レベルに応じて、処理時間の調整を行ってください。この処理は、製品だけでなく、ラボで調整された同成分のWorking Solutionにも適用されます。沈殿する化合物の量は濃度と温度によって異なりますが、標準液の希釈溶液であっても、ラベル記載の推奨温度を大きく下回る温度で保存する場合は、低温による化合物溶解度の低下が懸念されるため、通常よりも長い超音波処理時間を設定することをお勧めします。