Restek
ホーム / Reference Standards / ガス校正用スタンダード&アクセサリ / ガス校正用スタンダード / Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig
Restek
Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig
  1. Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig

Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig

カタログ番号 34414
ご注文時の注意点

Gas standards are subject to hazardous materials shipping fees by most freight carriers. All calibration gas standards are nonreturnable due to DOT hazardous shipping requirements.

Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig

Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig

概要

特徴&利点

Our high-quality air monitoring gas calibration standards are provided by Linde and Airgas—meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

As of December 2022, Restek is transitioning our 110 L standards to 124 L. Read more about this change here.

To view compatible regulators, see Recommended Products below.

製品詳細

Each of these gas standards comes with a certificate of analysis and unique serial number. All cylinders are disposable and do not require rental or demurrage fees. Recertification of cylinders is available directly with our suppliers. All cylinders are drop-shipped from our suppliers to provide fast delivery and the "freshest" standard possible. We ensure a minimum 12-month stability on all cylinders.

Benzene (71-43-2)
Ethylbenzene (100-41-4)
Toluene (108-88-3)
m-Xylene (108-38-3)
o-Xylene (95-47-6)
p-Xylene (106-42-3)

Linde 104 L Cylinders:
Aluminum construction
Size: 8 x 24 cm
Volume/Pressure: 104 liters of gas @ 1800 psig (124 bar)
Outlet Fitting: CGA-180
Weight: 1.5 lb/0.7 kg

Airgas 110 L Cylinders (PI-marked Cylinders for EU Regulations):
Aluminum construction
Size: 8.3 x 29.5 cm
Volume/Pressure: 110 liters of gas @ 1800 psig (124 bar)
Outlet Fitting: CGA-180
Weight: 2.2 lb/1 kg
U.S. DOT Specs: 3AL2216

Airgas 124 L Cylinders:
Aluminum construction
Size: 8.3 x 30 cm
Volume/Pressure: 124 liters of gas @ 1800 psig (124 bar)
Outlet Fitting: CGA-180
Weight: 2.3 lb/1 kg

Spectra Gases is now Linde.
Scott/Air Liquide is now Airgas.

仕様

製品仕様
カタログ番号
34414
製品名
Linde Air Standard, BTEX Gas Mixture, 1 ppm in N2, 104 L @ 1800 psig
Can't find what you're looking for?
カスタムガス校正用スタンダード

ガス校正用スタンダードのカスタム品に関するご相談も承っております。ご依頼やご質問はこちらからどうぞ。