ホーム / Reference Standards / 標準溶液 / 混合品 / Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul
Restek
Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul
  1. Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul

Restek

Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul

カタログ番号 36012
ご注文時の注意点

Additional USP <467> certified reference materials also available.

Using a large-volume Gas-Tight syringe? Be sure to choose the right liner.

Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul

Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul

概要

特徴&利点
  • Detect and quantify USP <467> Class 2 residual solvents in pharmaceuticals.
  • Reformulated to include cumene, added to USP <467> Class 2 list in August 2013.
  • Quantitatively tested to confirm composition and stability; detailed support documentation provided.
  • Restek is your complete supplier for world-class USP <467> residual solvent analysis: reference standards, Rxi-624Sil MS (G43) and Stabilwax (G16) GC columns, inlet liners, accessories, applications, and more.
製品詳細

The United States Pharmacopeia (USP) General Chapter <467> Residual Solvents is a widely used compendial method intended for identifying and quantifying residual solvents in drug substances, drug products, and excipients. In an attempt to better mirror the International Conference on Harmonization (ICH) guidelines, the USP has adopted a more comprehensive methodology in residual solvent testing—the current USP30/NF25. The ICH publishes a guideline (Q3C) listing the acceptable amounts of solvent residues that can be present. In the ICH guideline, residual solvents are summarized by class according to their toxicity. Class 1 compounds are carcinogenic compounds that pose a risk to both the consumer and the environment. The use of these solvents is to be avoided, but if they are used, they must be tightly controlled. Class 2 compounds are nongenotoxic animal carcinogens, and concentrations of these compounds should be limited. Chromatographic analysis is needed for both the Class 1 and Class 2 residual solvents.

This mixture reflects the changes made in USP <467> effective August 2013 and replaces Restek cat.# 36271.

Acetonitrile (75-05-8), 2.05 mg/mL
Chlorobenzene (108-90-7), 1.8 mg/mL
Cyclohexane (110-82-7), 19.4 mg/mL
cis-1,2-Dichloroethene (156-59-2), 4.675 mg/mL
trans-1,2-Dichloroethene (156-60-5), 4.675 mg/mL
1,4-Dioxane (123-91-1), 1.9 mg/mL
Ethylbenzene (100-41-4), 1.84 mg/mL
Isopropylbenzene (cumene) (98-82-8), 0.35 mg/mL
Methanol (67-56-1), 15 mg/mL
Methylcyclohexane (108-87-2), 5.9 mg/mL
Methylene chloride (dichloromethane) (75-09-2), 3 mg/mL
Tetrahydrofuran (109-99-9), 3.6 mg/mL
Toluene (108-88-3), 4.45 mg/mL
m-Xylene (108-38-3), 6.51 mg/mL
o-Xylene (95-47-6), 0.98 mg/mL
p-Xylene (106-42-3), 1.52 mg/mL

仕様

製品仕様
カタログ番号
36012
製品名
Residual Solvents Class 2 - Mix A (2013 Rev) 0.35-19.4 mg/mL, DMSO, 1 mL/ampul