Restek
ホーム / Reference Standards / 標準溶液 / 混合品 / Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
Restek
New
Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
  1. Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit

Restek

Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit

カタログ番号 36030
Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit

Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit

概要

特徴&利点
  • Includes all compounds listed for Michigan or Missouri state-specific residual solvents methods.
  • High analyte concentrations allow for flexible calibration curves.
  • Our proprietary manufacturing process was optimized to ensure standards are accurate, reproducible, and stable.
  • Second independent lots available to ensure you can meet your requirements without needing to source another supplier.
  • Verified composition and stability.
製品詳細

Contains one ampul of each of the following.

 

Cat.# 36027: Michigan/Missouri Residual Solvents Standard
500-5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul

CompoundCASConcentration
Benzene71-43-2500 µg/mL
1,2-Dichloroethane107-06-2500 µg/mL
Chloroform67-66-3500 µg/mL
Trichloroethylene (1,1,2-Trichloroethylene)79-01-6500 µg/mL
n-Hexane110-54-35000 µg/mL
2-methylpentane107-83-55000 µg/mL
3-methylpentane96-14-05000 µg/mL
2,2-dimethylbutane75-83-25000 µg/mL
2,3-dimethylbutane79-29-85000 µg/mL
Acetonitrile75-05-85000 µg/mL
Dichloromethane (Methylene chloride)75-09-25000 µg/mL
Toluene108-88-35000 µg/mL
1,2-dimethylbenzene (ortho-)95-47-65000 µg/mL
1,3-dimethylbenzene (meta-)108-38-35000 µg/mL
1,4-dimethylbenzene (para-)106-43-35000 µg/mL
Methanol (Methyl Alcohol)67-56-15000 µg/mL
Ethyl Acetate (Acetic Acid Ethyl Ester)141-78-65000 µg/mL
Heptane (n-Heptane)142-82-55000 µg/mL
Isopropyl Alcohol (2-Propanol, Isopropanol, IPA)67-63-05000 µg/mL
Ethyl Ether (Diethyl Ether, 1,1'-Oxybisethane)60-29-75000 µg/mL
Acetone67-64-15000 µg/mL
n-Pentane109-66-05000 µg/mL
iso-Pentane78-78-45000 µg/mL
Ethanol (Ethyl Alcohol)64-17-55000 µg/mL

 

Cat.# 36029: Ethylene Oxide Standard
5000 µg/mL, 1,2,4-trimethylbenzene, 1 mL/ampul

CompoundCASConcentration
Ethylene Oxide75-21-85000 µg/mL

 

Cat.# 36024: Residual Solvents Gases Standard Mix
5000 µg/mL, 1,2,4-trimethylbenzene, 2 mL/ampul

CompoundCASConcentration
n-Butane (C4)106-97-85000 µg/mL
2,2-Dimethylpropane (Neopentane)463-82-15000 µg/mL
2-Methylpropane (Isobutane)75-28-55000 µg/mL
n-Propane (C3)74-98-65000 µg/mL

仕様

製品仕様
カタログ番号
36030
製品名
Michigan/Missouri Residual Solvents Kit, 1,2,4-trimethylbenzene, 3 ampuls/kit
Can't find what you're looking for?
カスタムリファレンススタンダード

リファレンススタンダードのカスタム品に関するご相談も承っております。カスタム品のご依頼はこちらのフォームをご利用ください。