Restek
Home / Gas Chromatography / GC Columns / GC Fused Silica Capillary Columns / Rxi / Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm
Restek
Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm
Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm
Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm
  1. Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm
  2. Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm
  3. Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm

Restek

Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm

Catalog No. 16624
Ordering Note

The certificates of analysis (CofAs) for fused silica, MXT, and PLOT analytical GC columns manufactured after December 2024 will be paperless. After that time, these digital CofAs can be accessed at www.restek.com/documentation.

Need a guard column that is not shown here? We recommend Rxi guard columns and SilTite µ-Union connectors. You can connect a guard yourself or contact Customer Service to place a custom order for a factory-connected guard.

Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm

Rxi-SVOCms GC Capillary Column, 30 m, 0.32 mm ID, 0.25 µm

Overview

Features & Benefits

Named Best New Separations Product of the Year in SelectScience Scientists' Choice Awards, as voted by scientists around the world.

  • Column chemistry optimized specifically to give premium performance for semivolatiles in complex matrices.
  • Long column lifetime—restore performance with a quick trim instead of a time-consuming replacement.
  • Outstanding inertness keeps calibrations passing and samples running.
  • Excellent resolution of critical pairs for improved accuracy.
  • Consistent column-to-column performance.
  • Engineered to be a low-bleed GC-MS column.
  • Temperature range: -60 °C to 340 °C.
  • Equivalent to USP G27 and G36 phases.

Simplify calibration with SVOC MegaMix reference standards kits that contain 150 (cat.# 31907) or 100 (cat.# 31908) of the most frequently analyzed semivolatiles.

Description

Rxi-SVOCms columns keep your instrument online and analyzing semivolatiles (SVOC) samples instead of offline for time-consuming recalibration or column replacement. Designed specifically for improved semivolatiles performance, Rxi-SVOCms columns ensure consistent chromatography that will keep calibrations passing longer, so you can run more samples before needing to recalibrate the instrument or replace the column.