Restek
Home / Gas Chromatography / GC Columns / GC Packed Columns & Accessories / Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration
Restek
Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration
  1. Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration

Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration

Catalog No. 80485-800
Ordering Note

See Description below for column configuration key.

Note: Initial 2" of column will be empty, to accommodate a needle. For a completely filled column, contact your local Restek representative.

Agilent configuration also includes 1 1/2" void on detector side.

Custom packed and micropacked columns also available by request.

Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration

Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration

Overview

Features & Benefits
  • Optimized columns for low ppbv sulfur analyses.
  • Eliminate the need for PTFE tubing.
  • Columns are Sulfinert treated for maximum inertness. Sulfinert-treated end fittings are sold separately.
  • Maximum temperature of 290 °C.
Description

Sulfur analyses are traditionally performed using PTFE tubing to improve column inertness. Unfortunately, PTFE tubing is gas permeable, difficult to pack with high efficiency, prone to shrinkage, and has poor thermal stability. The Rt-XLSulfur packed or micropacked column eliminates these problems. The packing material for Rt-XLSulfur columns is extensively deactivated for analysis of low ppbv levels of hydrogen sulfide and methyl mercaptan. It is then treated to achieve effective separation of hydrocarbons from sulfur compounds. The interior wall and the end fittings of the Rt-XLSulfur column are Sulfinert treated, making the column as inert as PTFE. The extra care taken to manufacture this column ensures more accurate analyses of sulfur compounds.

Note: Columns do not include column nuts and ferrules. Optional installation kits can be ordered separately.

Column Configuration Key:
-800 General—General Configuration
-810 Agilent Standard—(HP) 5880, 5890, 5987, 6890, 7890, 8890
-820 Scion (Bruker 430, 450) (Varian Standard—Scion 3700, Vista Series, FID)
-840 PerkinElmer Standard—PE Auto System 8300/8400/8700, Clarus 500
-850 Shimadzu 14A—Shimadzu 14A, 2014

Other column configurations available. If you don't see the configuration you need listed below, contact your local Restek representative.

Specifications

Product Specifications
Catalog No.
80485-800
Product Name
Rt-XLSulfur Packed GC Column, 100/120, 2 m, 2.0 mm ID, 1/8" OD, Sulfinert Tubing, General Configuration
Can't find what you're looking for?
Custom Packed/Micropacked Columns

Packed and micropacked columns can be made to order to suit both your instrument and application.