Benvenuti nel nuovo sito Restek.com! Fate un tour e sentiti liberi di inviarci un vostro riscontro

Il tuo browser web non sarà più supportato da Restek.com a partire dal 30 giugno 2021.
Per evitare qualsiasi interruzione di accesso o alle nostre funzionalità, installa subito un browser web di generazione. Per saperne di più.

Condividi:

Kit pesticidi multiresidui LC

  • Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.
  • Full kit contains 204 compounds of interest, covering many LC-determined pesticides listed by government agencies; individual ampuls also sold separately.
  • Formulated and grouped for maximum long-term stability.
  • Quantitatively tested to confirm composition; detailed support documentation provided.
  • Optimized multiresidue pesticide method is offered free of charge; downloadable XLS file includes conditions and transition tables.
  • Restek is your complete supplier for world-class LC-MS/MS multiresidue pesticide analysis: reference and internal standards, Ultra and Pinnacle DB LC columns, Q-sep QuEChERS sample prep products, accessories, and more!

* Note: When combining a large number of compounds with different chemical functionalities, mix stability can be an issue. In formulating these standards, we extensively studied the 204 compounds involved, and then grouped them into as few mixes as possible while still ensuring maximum long-term stability and reliability. For quantitative analysis, we recommend analyzing each mix separately to ensure accurate results for every compound.

Materiali di Riferimento Certificati (CRMs) prodotti e testati all’interno di laboratori accreditati ISO, per soddisfare i vostri requisiti ISO

Kit pesticidi multiresidui LC

Catalog #

Selezionare un N. di Catalogo tra quelli in elenco
Disponibilità:
Prezzo:
Totale:
Find a Distributor
Selezionare un N. di Catalogo tra quelli in elenco

Opzioni prodotto

Volete sapere quale prodotto Restek è il più adatto alla vostra applicazione? Contattate il servizio tecnico.
Catalog # Cancella tutto
31971 kit Contains 1 mL each of these mixtures. Kit pesticidi multiresidui LC Seleziona Deselect

Catalog # 31971

Unità
kit  
Conc. in Solvente e Volume
Contains 1 mL each of these mixtures.  
Nome Prodotto
Kit pesticidi multiresidui LC  
Materiali di Riferimento Certificati (CRM)
Sì  
Shelf Life Minima Garantita in data di Spedizione*
6 mesi  
Condizioni di Spedizione
Temperatura Ambiente  
Temperatura di Conservazione
-20 °C o a temperature inferiori  

    Cat.# 31972: LC Multiresidue Pesticide Standard #1 (13 components)
    Organophosphorus Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Acephate (30560-19-1)
    Carbaryl (Sevin) (63-25-2)
    Dicrotophos (141-66-2)
    Dimethoate (60-51-5)
    Dimethomorph (110488-70-5)
    Isocarbophos (24353-61-5)
    Methamidophos (10265-92-6)
    Mevinphos (7786-34-7)
    Monocrotophos (6923-22-4)
    Omethoate (1113-02-6)
    Temephos (Abate) (3383-96-8)
    Trichlorfon (Dylox) (52-68-6)
    Vamidothion (Vamidoate) (2275-23-2)

    Cat.# 31973: LC Multiresidue Pesticide Standard #2 (16 components)
    Carbamate/Uron Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Alanycarb (83130-01-2)
    Aldicarb (116-06-3)
    Aldicarb sulfone (1646-88-4)
    Aldicarb sulfoxide (1646-87-3)
    Benfuracarb (82560-54-1)
    Butocarboxim (34681-10-2)
    Butoxycarboxim (34681-23-7)
    Ethiofencarb (29973-13-5)
    Furathiocarb (65907-30-4)
    Methabenzthiazuron (18691-97-9)
    Methiocarb (2032-65-7)
    Methomyl (16752-77-5)
    Oxamyl (23135-22-0)
    Tebuthiuron (34014-18-1)
    Thidiazuron (51707-55-2)
    Thiophanate-methyl (23564-05-8)

    Cat.# 31974: LC Multiresidue Pesticide Standard #3 (38 components)
    Carbamate/Uron Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Bendiocarb (22781-23-3)
    Bifenazate (149877-41-8)
    Carbofuran (1563-66-2)
    Chlorfluazuron (71422-67-8)
    Chloroxuron (1982-47-4)
    Chlortoluron (15545-48-9)
    Cycluron (2163-69-1)
    Diethofencarb (87130-20-9)
    Diflubenzuron (35367-38-5)
    Dioxacarb (6988-21-2)
    Diuron (330-54-1)
    Fenobucarb (BPMC) (3766-81-2)
    Fenoxycarb (72490-01-8)
    Fenuron (101-42-8)
    Flufenoxuron (101463-69-8)
    Fluometuron (2164-17-2)
    Forchlorfenuron (68157-60-8)
    Hexaflumuron (86479-06-3)
    3-Hydroxycarbofuran (16655-82-6)
    Indoxacarb (173584-44-6)
    Iprovalicarb (140923-17-7)
    Isoprocarb (2631-40-5)
    Isoproturon (34123-59-6)
    Linuron (330-55-2)
    Lufenuron (103055-07-8)
    Metobromuron (3060-89-7)
    Monolinuron (1746-81-2)
    Neburon (555-37-3)
    Novaluron (116714-46-6)
    Pirimicarb (23103-98-2)
    Promecarb (2631-37-0)
    Propham (122-42-9)
    Propoxur (Baygon) (114-26-1)
    Pyraclostrobin (175013-18-0)
    Siduron (1982-49-6)
    Teflubenzuron (83121-18-0)
    Thiobencarb (28249-77-6)
    Triflumuron (64628-44-0)

    Cat.# 31975: LC Multiresidue Pesticide Standard #4 (63 components)
    Organonitrogen Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Abamectin (71751-41-2)
    Acetamiprid (135410-20-7)
    Ametryn (834-12-8)
    Amitraz (33089-61-1)
    Azoxystrobin (131860-33-8)
    Benalaxyl (71626-11-4)
    Benzoximate (29104-30-1)
    Boscalid (188425-85-6)
    Butafenacil (134605-64-4)
    Carbetamide (16118-49-3)
    Carfentrazone ethyl (128639-02-1)
    Chlorantraniliprole (500008-45-7)
    Clofentezine (74115-24-5)
    Cymoxanil (57966-95-7)
    Cyprodinil (121552-61-2)
    Cyromazine (66215-27-8)
    Dimoxystrobin (149961-52-4)
    Dinotefuran (165252-70-0)
    Doramectin (117704-25-3)
    Eprinomectin (123997-26-2)
    Famoxadon (131807-57-3)
    Fenazaquin (120928-09-8)
    Fenhexamid (126833-17-8)
    Fenpyroximate (111812-58-9)
    Flonicamid (158062-67-0)
    Fluazinam** (79622-59-6)
    Fludioxonil (131341-86-1)
    Fluoxastrobin (361377-29-9)
    Flutolanil (66332-96-5)
    Furalaxyl (57646-30-7)
    Halofenozide (112226-61-6)
    Imazalil (35554-44-0)
    Imidacloprid (138261-41-3)
    Ivermectin (70288-86-7)
    Kresoxim methyl (143390-89-0)
    Mandipropamid (374726-62-2)
    Mepanipyrim (110235-47-7)
    Mepronil (55814-41-0)
    Metaflumizone (139968-49-3)
    Metalaxyl (57837-19-1)
    Methoxyfenozide (161050-58-4)
    Moxidectin (113507-06-5)
    Myclobutanil (88671-89-0)
    Nitenpyram (120738-89-8)
    Oxadixyl (77732-09-3)
    Picoxystrobin (117428-22-5)
    Piperonyl butoxide (51-03-6)
    Prochloraz (67747-09-5)
    Prometon (1610-18-0)
    Pymetrozine (123312-89-0)
    Pyracarbolid (24691-76-7)
    Pyrimethanil (53112-28-0)
    Pyriproxyfen (95737-68-1)
    Quinoxyfen (124495-18-7)
    Rotenone (83-79-4)
    Secbumeton (26259-45-0)
    Spiroxamine (118134-30-8)
    Tebufenozide (112410-23-8)
    Tebufenpyrad (119168-77-3)
    Terbumeton (33693-04-8)
    Triadimefon (43121-43-3)
    Trifloxystrobin (141517-21-7)
    Zoxamide (156052-68-5)

    Cat.# 31976: LC Multiresidue Pesticide Standard #5 (30 components)
    Organonitrogen Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Acibenzolar-S-methyl (135158-54-2)
    Bupirimate (41483-43-6)
    Buprofezin (69327-76-0)
    Carboxin (5234-68-4)
    Clethodim (99129-21-2)
    Clothianidin (210880-92-5)
    Cyazofamid (120116-88-3)
    Ethiprole (181587-01-9)
    Ethofumesate (26225-79-6)
    Fenamidone (161326-34-7)
    Fipronil (120068-37-3)
    Flubendiamide (272451-65-7)
    Flufenacet (Fluthiamide) (142459-58-3)
    Hexythiazox (78587-05-0)
    Mefenacet (73250-68-7)
    Mesotrione (104206-82-8)
    Methoprotryne (841-06-5)
    Metribuzin (21087-64-9)
    Prometryne (7287-19-6)
    Propargite (2312-35-8)
    Prothioconazole (178928-70-6)
    Pyridaben (96489-71-3)
    Simetryn (1014-70-6)
    Sulfentrazone (122836-35-5)
    Terbutryn (886-50-0)
    Thiabendazole (148-79-8)
    Thiacloprid (111988-49-9)
    Thiamethoxam (153719-23-4)
    Thiofanox (39196-18-4)
    Tricyclazole (Beam) (41814-78-2)

    Cat.# 31977: LC Multiresidue Pesticide Standard #6 (28 components)
    Organonitrogen Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Baycor (Bitertanol) (55179-31-2)
    Bromuconazole (116255-48-2)
    Cyproconazole (94361-06-5)
    Diclobutrazol (75736-33-3)
    Difenoconazole (119446-68-3)
    Diniconazole (83657-24-3)
    Epoxiconazole (133855-98-8)
    Etaconazole (60207-93-4)
    Ethirimol (23947-60-6)
    Etoxazole (153233-91-1)
    Fenarimol (60168-88-9)
    Fenbuconazole (114369-43-6)
    Fluquinconazole (136426-54-5)
    Flusilazole (85509-19-9)
    Flutriafol (76674-21-0)
    Fuberidazole (3878-19-1)
    Hexaconazole (79983-71-4)
    Ipconazole (125225-28-7)
    Metconazole (125116-23-6)
    Nuarimol (63284-71-9)
    Paclobutrazol (76738-62-0)
    Penconazole (66246-88-6)
    Propiconazole (Tilt) (60207-90-1)
    Tebuconazole (107534-96-3)
    Tetraconazole (112281-77-3)
    Triadimenol (55219-65-3)
    Triflumizole (68694-11-1)
    Triticonazole (131983-72-7)

    Cat.# 31978: LC Multiresidue Pesticide Standard #7 (7 components)
    Organonitrogen Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Emamectin-benzoate (155569-91-8)
    Fenpropimorph (67564-91-4)
    Spirodiclofen (148477-71-8)
    Spinosad (168316-95-8)
    Spirotetramat (203313-25-1)
    Spinetoram (J&L) (935545-74-7)
    Spiromesifen (283594-90-1)

    Cat.# 31979: LC Multiresidue Pesticide Standard #8
    Organonitrogen Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Hydramethylnon (67485-29-4)

    Cat.# 31980: LC Multiresidue Pesticide Standard #9 (7 components)
    Carbamate/Uron Compounds
    100 µg/mL each in acetonitrile, 1 mL/ampul
    Aminocarb (2032-59-9)
    Desmedipham (13684-56-5)
    Formetanate HCL (23422-53-9)
    Mexacarbate (Zectran) (315-18-4)
    Monceren (Pencycuron) (66063-05-6)
    Phenmedipham (13684-63-4)
    Propamocarb free base (24579-73-5)

    Cat.# 31981: LC Multiresidue Pesticide Standard #10
    Carbamate/Uron Compounds
    100 µg/mL each in methanol, 1 mL/ampul
    Carbendazim (10605-21-7)

* NOTE: When combining a large number of compounds with different chemical functionalities, mix stability can be an issue. In formulating these standards, we extensively studied the 204 compounds involved, then grouped them into as few mixes as possible while still ensuring maximum long-term stability and reliability. For quantitative analysis, we recommend analyzing each mix separately to ensure accurate results for every compound.
** NOTE: In this standard, fluazinam should only be used for qualitative analysis. A single-component standard (cat.# 31982) is available for quantitative analysis.