Semivolatiles on Rxi-SVOCms

GC_EV1505
PeakstR (min)
1.1,4-Dioxane-d83.44
2.1,4-Dioxane3.48
3.N-Nitrosodimethylamine3.87
4.Pyridine3.94
5.Ethyl methacrylate4.50
6.2-Picoline4.96
7.N-Nitrosomethylethylamine5.08
8.Methyl methanesulfonate5.52
9.(SS) 2-Fluorophenol5.77
10.N-Nitrosodiethylamine6.14
11.Ethyl methanesulfonate6.59
12.Benzaldehyde7.19
13.(SS) Phenol-d67.23
14.Phenol7.26
15.Aniline7.36
16.Bis(2-chloroethyl) ether7.45
17.Pentachloroethane7.46
18.2-Chlorophenol7.57
19.1,3-Dichlorobenzene7.85
20.(IS) 1,4-Dichlorobenzene-D47.95
21.1,4-Dichlorobenzene7.98
22.Benzyl alcohol8.15
23.1,2-Dichlorobenzene8.25
24.2-Methylphenol8.33
25.Bis(2-Chloroisopropyl)ether8.41
26.N-Nitrosopyrrolidine8.59
27.4-Methylphenol8.61
28.3-Methylphenol8.61
29.N-Nitrosodi-N-propylamine8.64
30.Acetophenone8.65
31.4-Nitrosomorpholine8.66
32.o-Toluidine8.71
33.Hexachloroethane8.87
34.(SS) Nitrobenzene-D58.93
35.Nitrobenzene8.96
36.N-Nitrosopiperidine9.23
37.Isophorone9.40
38.2-Nitrophenol9.56
39.2,4-Dimethylphenol9.61
40.Benzoic acid9.69
41.Bis(2-chloroethoxy)methane9.80
42.2,4-Dichlorophenol10.00
43.1,2,4-Trichlorobenzene10.18
44.Phentermine10.18
45.(IS) Naphthalene-D810.30
46.Naphthalene10.34
47.4-Chloroaniline10.42
48.2,6-Dichlorophenol10.44
PeakstR (min)
49.Hexachloropropene10.51
50.Hexachlorobutadiene10.58
51.Caprolactam11.05
52.N-Nitroso-N-butylamine11.08
53.1,4-Phenylenediamine11.09
54.4-Chloro-3-methylphenol11.34
55.Isosafrole I11.50
56.2-Methylnaphthalene11.69
57.1-Methylnaphthalene11.88
58.Hexachlorocyclopentadiene12.00
59.1,2,4,5-Tetrachlorobenzene12.01
60.Isosafrole II12.08
61.2,4,6-Trichlorophenol12.23
62.2,4,5-Trichlorophenol12.29
63.(SS) 2-Fluorobiphenyl12.41
64.Safrole12.53
65.Biphenyl12.61
66.2-Chloronaphthalene12.65
67.1-Chloronaphthalene12.69
68.Diphenyl ether12.82
69.2-Nitroaniline12.83
70.1,4-Naphthoquinone12.98
71.1,2-Dinitrobenzene13.06
72.1,3-Dinitrobenzene13.10
73.Dimethyl phthalate13.20
74.2,6-Dinitrotoluene13.32
75.1,4-Dinitrobenzene13.41
76.Acenaphthylene13.47
77.3-Nitroaniline13.64
78.(IS) Acenaphthene-d1013.75
79.Acenaphthene13.82
80.2,4-Dinitrophenol13.85
81.4-Nitrophenol13.95
82.Pentachlorobenzene14.08
83.2,4-Dinitrotoluene14.12
84.Dibenzofuran14.16
85.1-Naphthalamine14.31
86.2,3,5,6-Tetrachlorophenol14.31
87.2,3,4,6-Tetrachlorophenol14.39
88.2-Naphthalamine14.46
89.Diethyl Phthalate14.61
90.Fluorene14.85
91.4-Chlorophenyl phenyl ether14.85
92.2-Methyl-5-nitroaniline14.85
93.4-Nitroaniline14.85
94.4,6-Dinitro-2-methylphenol14.92
95.N-Nitrosodiphenylamine15.07
96.N,N-Diphenylhydrazine15.16
PeakstR (min)
97.(SS) 2,4,6-Tribromophenol15.32
98.1,3,5-Trinitrobenzene15.57
99.Phenacetin15.67
100.Diallate15.72
101.4-Bromophenyl phenyl ether15.82
102.Hexachlorobenzene15.94
103.Atrazine16.14
104.Pentachlorophenol16.32
105.4-Aminobiphenyl16.33
106.Pentachloronitrobenzene16.36
107.Propyzamide16.46
108.(IS) Phenanthrene-D1016.72
109.Phenanthrene16.77
110.Anthracene16.86
111.Carbazole17.18
112.di-n-Butyl phthalate17.89
113.4-Nitroquinoline 1-oxide18.29
114.Isodrin18.85
115.Fluoranthene19.14
116.Benzidine19.40
117.(SS) Pyrene-D1019.56
118.Pyrene19.59
119.Aramite I19.87
120.(SS) p-Terphenyl-d1419.91
121.Aramite II20.02
122.Dimethylaminoazobenzene20.19
123.4,4'-Dichlorobenzilate20.28
124.3,3'-Dimethylbenzidine20.87
125.Butyl benzyl phthalate20.91
126.Kepone20.99
127.Bis(2-ethylhexyl) adipate21.09
128.2-(Acetylamino)fluorene21.41
129.3,3'-Dichlorobenzidine22.11
130.Benz[a]anthracene22.18
131.(IS) Chrysene-D1222.21
132.Chrysene22.27
133.Bis(2-ethylhexyl) phthalate22.28
134.Di-n-octyl phthalate24.14
135.Benzo[b]fluoranthene25.24
136.7,12-Dimethylbenzo[a]anthracene25.24
137.Benzo[k]fluoranthene25.33
138.Benzo[a]pyrene26.30
139.(IS) Perylene-D1226.48
140.3-Methylcholanthrene27.50
141.Dibenz[a,j]acridine29.58
142.Indeno[1,2,3-cd]pyrene30.18
143.Dibenz[a,h]anthracene30.28
144.Benzo[ghi]perylene31.11
ColumnRxi-SVOCms, 30 m, 0.25 mm ID, 0.50 µm (cat.# 16638)
Standard/Sample8270/Appendix IX kit (cat.# 31815)
Revised B/N surrogate mix (cat.# 31888)
Acid surrogate mix (cat.# 31063)
Diluent:Dichloromethane
Conc.:20 µg/mL (2 ng on-column)
Injection
Inj. Vol.:1 µL split (split ratio 10:1)
Liner:Topaz 4.0 mm ID single taper inlet liner w/ wool (cat.# 23303)
Inj. Temp.:250 °C
Oven
Oven Temp.:40 °C (hold 1 min) to 280 °C at 12.4 °C/min to 330 °C at 3.3 °C/min (hold 3.65 min)
Carrier GasHe, constant flow
Flow Rate:1.2 mL/min
DetectorMS
Mode:Scan
Scan Program:
GroupStart Time
(min)
Scan Range
(amu)
Scan Rate
(scans/sec)
12.050-5003.6
Transfer Line Temp.:280 °C
Analyzer Type:Quadrupole
Source Type:Inert
Drawout Plate:6 mm ID
Source Temp.:330 °C
Quad Temp.:180 °C
Electron Energy:70 eV
Solvent Delay Time:2 min
Tune Type:DFTPP
Ionization Mode:EI
InstrumentAgilent 7890A GC & 5975C MSD
Sample PreparationSamples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (cat.# 21143) containing glass Big Mouth inserts (cat.# 21782) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (cat.# 23842).