Influencing Selectivity in LC-MS Peptides Analysis on the Raptor ARC-18 Column

Author: Sharon Lupo, Frances Carroll

Restek Corporation

Published By: Restek Corporation

Year of Publication: 2017

Link: http://www.restek.com/Technical-Resources/Technical-Library/Pharmaceutical/pharma_PHAN2615-UNV

Abstract:

Methods for LC-MS peptide analysis often use acidified mobile phases, which can alter retention and selectivity. Here, we demonstrate the effects of modifying acid type, acid concentration, temperature, and gradient slope using several test probes. A Raptor ARC-18 column was employed for this work because the stationary phase ligand is sterically protected, making it extremely stable and resistant to acid damage at low pHs, which is an important characteristic when developing LC-MS methods for peptide analysis.

New Raptor™ ARC-18 Columns Are Born for LC-MS/MS

The birth of Restek’s new Raptor™ SPP LC column line began with the innovative Biphenyl phase, and it has now grown to include a new Restek® phase: the ARC-18.

Raptor™ LC ColumnsRaptor™ ARC-18 ColumnDesigned and intended specifically for use on LC-MS/MS systems, the Raptor™ ARC-18 column offers a well-balanced retention profile without the drawbacks of using an ordinary C18 in the harsh, acidic mobile phases needed for mass spectrometry (MS). Even after extended use in these low-pH (≤ 2.0) conditions, the sterically protected ARC-18 offers consistent retention, peak shape, and response for charged bases, neutral acids, small polar compounds, and more. For the rapid analysis of large, multiclass assays by LC-MS/MS, the Raptor™ ARC-18 truly is ahead of the curve.

www.restek.com/raptor

 

About Raptor™ SPP LC Columns: Superficially porous particles (commonly referred to as SPP or “core-shell” particles) changed the world of LC by dramatically boosting column efficiency and reducing analysis times, but they were only the beginning. With Raptor™ LC columns, Restek chemists have combined the speed of SPP with the resolution of highly selective USLC® technology. This new species of chromatographic column allows you to more easily achieve peak separation and faster analysis times without expensive UHPLC instrumentation. Raptor™ LC columns provide the practicing analyst with the most powerful tools available for fast, efficient method development and increased sample throughput. And because they are from Restek, Raptor™ LC columns are backed by manufacturing and quality systems you trust along with internationally renowned Plus 1 service.